SIRS、qSOFA与NEWS在急诊科脓毒症早期识别中的比较
该回顾性分析纳入130,595例成人急诊就诊,比较SIRS、qSOFA和NEWS在分诊时识别严重脓毒症/脓毒性休克(SS/SS)的效能。NEWS对SS/SS、脓毒性休克和脓毒症相关死亡的AUROC分别为0.91、0.93、0.95,均高于SIRS和qSOFA(p<0.01)。NEWS≥4与SIRS≥2敏感性相似(84.2% vs 86.1%),但NEWS特异性更高(85.0% vs 79.1%),且无需实验室检查即可计算。qSOFA≥2敏感性仅28.5%,不适合急诊脓毒症筛查。
要点
- NEWS对SS/SS的AUROC为0.91,高于SIRS的0.88和qSOFA的0.81(p<0.01)。
- NEWS≥4与SIRS≥2识别SS/SS敏感性相似(84.2% vs 86.1%),但NEWS特异性更高(85.0% vs 79.1%)。
- qSOFA≥2识别SS/SS敏感性仅28.5%,特异性98.9%,作为急诊筛查工具敏感性不足。
- NEWS对脓毒症相关死亡AUROC达0.95,准确性随疾病严重程度提高。
- NEWS无需实验室检查即可即时获得,但评分计算较复杂,可能更适合自动化计算。
适用人群与场景
- 城市三级学术中心急诊科成人就诊者(共130,595例次),排除缺乏充分临床评估的离院病例(n=14,861,11.4%)。
- 严重脓毒症/脓毒性休克组(n=930)通过出院诊断和病历回顾确定。
诊断标准与关键阈值
- NEWS≥4:识别SS/SS敏感性84.2%(95%CI 81.5-86.5%),特异性85.0%(95%CI 84.8-85.3%)。
- SIRS≥2:识别SS/SS敏感性86.1%(95%CI 83.6-88.2%),特异性79.1%(95%CI 78.9-79.3%)。
- qSOFA≥2:识别SS/SS敏感性28.5%(95%CI 25.6-31.7%),特异性98.9%(95%CI 98.8-99.0%)。
研究设计与关键结果
- 回顾性分析纳入130,595例次成人急诊就诊,SS/SS组930例。
- NEWS、SIRS、qSOFA识别SS/SS的AUROC分别为0.91、0.88、0.81(NEWS vs SIRS和qSOFA,p<0.01)。
- 识别脓毒性休克的AUROC分别为NEWS 0.93、SIRS 0.88、qSOFA 0.84。
- 识别脓毒症相关死亡的AUROC分别为NEWS 0.95、SIRS 0.89、qSOFA 0.87。
- NEWS≥4 vs SIRS≥2 vs qSOFA≥2:敏感性84.2% vs 86.1% vs 28.5%,特异性85.0% vs 79.1% vs 98.9%。
证据类型、等级与局限
- 证据类型:回顾性分析,单中心。
- 局限:原文未报告局限性。
对床旁实践的改变
- NEWS在急诊分诊识别SS/SS、脓毒性休克和脓毒症相关死亡方面准确性最高,且无需实验室检查即可即时获得。
- NEWS较SIRS特异性更高而敏感性相似,且准确性随疾病严重程度提高。
- qSOFA敏感性最低,作者认为其是急诊脓毒症筛查的较差工具。
- NEWS评分计算较复杂,作者认为可能更适合自动化计算。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: The increasing use of sepsis screening in the Emergency Department (ED) and the Sepsis-3 recommendation to use the quick Sepsis-related Organ Failure Assessment (qSOFA) necessitates validation. We compared Systemic Inflammatory Response Syndrome (SIRS), qSOFA, and the National Early Warning Score (NEWS) for the identification of severe sepsis and septic shock (SS/SS) during ED triage.
METHODS: This was a retrospective analysis from an urban, tertiary-care academic center that included 130,595 adult visits to the ED, excluding dispositions lacking adequate clinical evaluation (n = 14,861, 11.4%). The SS/SS group (n = 930) was selected using discharge diagnoses and chart review. We measured sensitivity, specificity, and area under the receiver-operating characteristic (AUROC) for the detection of sepsis endpoints.
RESULTS: NEWS was most accurate for triage detection of SS/SS (AUROC = 0.91, 0.88, 0.81), septic shock (AUROC = 0.93, 0.88, 0.84), and sepsis-related mortality (AUROC = 0.95, 0.89, 0.87) for NEWS, SIRS, and qSOFA, respectively (p < 0.01 for NEWS versus SIRS and qSOFA). For the detection of SS/SS (95% CI), sensitivities were 84.2% (81.5-86.5%), 86.1% (83.6-88.2%), and 28.5% (25.6-31.7%) and specificities were 85.0% (84.8-85.3%), 79.1% (78.9-79.3%), and 98.9% (98.8-99.0%) for NEWS ≥ 4, SIRS ≥ 2, and qSOFA ≥ 2, respectively.
CONCLUSIONS: NEWS was the most accurate scoring system for the detection of all sepsis endpoints. Furthermore, NEWS was more specific with similar sensitivity relative to SIRS, improves with disease severity, and is immediately available as it does not require laboratories. However, scoring NEWS is more involved and may be better suited for automated computation. QSOFA had the lowest sensitivity and is a poor tool for ED sepsis screening.
参考来源
- Usman OA, Usman AA, Ward MA, et al. Comparison of SIRS, qSOFA, and NEWS for the early identification of sepsis in the Emergency Department. Am J Emerg Med. 2018. PMID: 30470600. doi:10.1016/j.ajem.2018.10.058
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。