急性肾损伤患者呼气挥发性有机化合物及其透析期间的变化
这项前瞻性观察性可行性研究在德国一家大学医院ICU纳入20例镇静、插管、机械通气的急性肾损伤且具透析指征的患者,从开始连续静脉-静脉血液透析前至少30分钟至开始后7小时,每20分钟从呼吸回路采集呼气样本,用多毛细管柱离子迁移谱分析。共检测到60种不同信号,其中44种可鉴定;34种挥发性物质在透析期间下降,26种不受影响。与肾功能正常通气对照组相比,45种信号在急性肾损伤患者中强度显著更高,其中30种在透析期间显著下降。作者认为呼气分析可能有助于量化急性肾损伤严重程度和评估透析效果。
要点
- 20例镇静插管机械通气的急性肾损伤透析患者中,呼气检测到60种信号、44种可鉴定,34种在透析期间下降、26种不受影响。
- 与肾功能正常通气对照相比,45种信号在急性肾损伤患者中强度显著更高,其中30种在连续静脉-静脉血液透析期间显著下降。
- 环己醇、3-羟基-2-丁酮、3-甲基丁醛和异戊二烯二聚体在急性肾损伤组强度显著高于对照组,且7小时连续静脉-静脉血液透析后显著下降。
- 作者认为呼气分析可能有助于量化急性肾损伤严重程度和评估透析效果。
适用人群与场景
- 德国一家大学医院ICU中20例镇静、插管、机械通气的急性肾损伤患者,且具透析指征。
- 对照为肾功能正常的通气患者。
处置流程与药物剂量
- 从连续静脉-静脉血液透析开始前至少30分钟至开始后7小时,每20分钟从呼吸回路采集呼气样本,用多毛细管柱离子迁移谱分析。
研究设计与关键结果
- 前瞻性观察性可行性研究,20例镇静插管机械通气的急性肾损伤透析患者,在德国一家大学医院ICU进行。
- 共检测到60种不同信号,44种可鉴定;34种挥发性物质在血液透析期间下降,26种不受影响。
- 与肾功能正常对照相比,45种信号在急性肾损伤患者中强度显著更高,其中30种在血液透析期间显著下降。
- 环己醇在急性肾损伤组为23 mV(2575th,19-38),对照组为12 mV(10-16),7小时连续静脉-静脉血液透析后降至16 mV(13-21),p<0.05。
- 3-羟基-2-丁酮在急性肾损伤组为16 mV(9-26),对照组为8 mV(7-14),7小时连续静脉-静脉血液透析后降至7 mV(6-13),p<0.05。
- 3-甲基丁醛在急性肾损伤组为20 mV(14-26),对照组未检出,7小时连续静脉-静脉血液透析后降至9 mV(8-13),p<0.05。
- 异戊二烯二聚体在急性肾损伤组为26 mV(18-32),对照组为4 mV(0-6),7小时连续静脉-静脉血液透析后降至14 mV(10-19),p<0.05。
证据类型、等级与局限
- 证据类型:前瞻性观察性可行性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为呼气分析可能有助于量化急性肾损伤严重程度和评估透析效果。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: To characterize volatile organic compounds in breath exhaled by ventilated care patients with acute kidney injury and changes over time during dialysis.
DESIGN: Prospective observational feasibility study.
SETTING: Critically ill patients on an ICU in a University Hospital, Germany.
PATIENTS: Twenty sedated, intubated, and mechanically ventilated patients with acute kidney injury and indication for dialysis.
INTERVENTIONS: Patients exhalome was evaluated from at least 30 minutes before to 7 hours after beginning of continuous venovenous hemodialysis.
MEASUREMENTS AND MAIN RESULTS: Expired air samples were aspirated from the breathing circuit at 20-minute intervals and analyzed using multicapillary column ion-mobility spectrometry. Volatile organic compound intensities were compared with a ventilated control group with normal renal function. A total of 60 different signals were detected by multicapillary column ion-mobility spectrometry, of which 44 could be identified. Thirty-four volatiles decreased during hemodialysis, whereas 26 remained unaffected. Forty-five signals showed significant higher intensities in patients with acute kidney injury compared with control patients with normal renal function. Among these, 30 decreased significantly during hemodialysis. Volatile cyclohexanol (23 mV; 2575th, 19-38), 3-hydroxy-2-butanone (16 mV, 9-26), 3-methylbutanal (20 mV; 14-26), and dimer of isoprene (26 mV; 18-32) showed significant higher intensities in acute kidney impairment compared with control group (12 mV; 10-16 and 8 mV; 7-14 and not detectable and 4 mV; 0-6; p < 0.05) and a significant decline after 7 hours of continuous venovenous hemodialysis (16 mV; 13-21 and 7 mV; 6-13 and 9 mV; 8-13 and 14 mV; 10-19).
CONCLUSIONS: Exhaled concentrations of 45 volatile organic compounds were greater in critically ill patients with acute kidney injury than in patients with normal renal function. Concentrations of two-thirds progressively decreased during dialysis. Exhalome analysis may help quantify the severity of acute kidney injury and to gauge the efficacy of dialysis.
参考来源
- Hüppe T, Klasen R, Maurer F, et al. Volatile Organic Compounds in Patients With Acute Kidney Injury and Changes During Dialysis. Crit Care Med. 2019. PMID: 30365402. doi:10.1097/CCM.0000000000003523
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。