一种新的超声心动图工具用于心输出量评估:一项实验研究
本研究在18只麻醉机械通气的失血性休克小猪模型中,将新型经胸超声心动图自动工具测得的VTIauto及COauto与热稀释法COth进行相关性分析,同时比较手动测量VTI计算的CO及VTIvaresp的前负荷依赖性。共尝试204次测量,手动测量成功率97%(197次),自动测量成功率60%(122次),差异有统计学意义(P<0.01)。COth与COauto的相关系数r=0.83(95%CI 0.76-0.88,P<0.01),高于与COave(r=0.54)、COmax(r=0.43)、COmed(r=0.58)、COmin(r=0.52)的相关性。结论认为在失血性休克实验模型中,COauto似乎比手动超声测量与COth的相关性更好。
要点
- 在失血性休克小猪模型中,COauto与热稀释法COth的相关系数r=0.83(95%CI 0.76-0.88,P<0.01),高于手动超声各测量值(r=0.43-0.58)。
- 自动测量成功率仅60%(122/204),手动测量成功率为97%(197/204),两者差异有统计学意义(P<0.01)。
- 手动测量中COmed与COth相关性最高(r=0.58,95%CI 0.48-0.67,P<0.01),但仍低于COauto。
- 该研究为动物实验(失血性休克小猪模型),结论需在临床人群中进一步验证。
适用人群与场景
- 麻醉、机械通气的失血性休克小猪模型(18只),通过放血使平均动脉压降至40 mm Hg,控制性失血维持30分钟后进行复苏。
研究设计与关键结果
- 研究类型:实验研究(动物模型),样本量18只小猪。
- 干预:使用新型经胸超声心动图工具自动计算VTIauto和COauto,并与热稀释法COth(Pulse index Contour Cardiac Output)比较;同时手动测量VTI计算CO(COmax、COmed、COmin、COave)。
- 主要终点:COth与COauto的相关系数r=0.83(95%CI 0.76-0.88,P<0.01)。
- 次要终点:COth与COave的r=0.54(95%CI 0.43-0.63,P<0.01);与COmax的r=0.43(95%CI 0.31-0.54,P<0.01);与COmed的r=0.58(95%CI 0.48-0.67,P<0.01);与COmin的r=0.52(95%CI 0.41-0.62,P<0.01)。
- 测量成功率:手动测量197/204(97%),自动测量122/204(60%),P<0.01。
证据类型、等级与局限
- 证据类型:动物实验研究(失血性休克小猪模型)。
对床旁实践的改变
- 作者认为,在失血性休克实验模型中,新型超声工具COauto似乎比手动超声心动图测量与热稀释法COth的相关性更好。
- 该研究为动物实验,结果不能直接推及临床急诊或ICU患者。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: The correlation between cardiac output (CO) evaluated by echocardiography and CO measured by thermodilution (COth) varies according to different studies. A new transthoracic echocardiography (TTE) tool allows automatic calculation of the subaortic velocity time index (VTIauto) and CO (COauto). The main objective was to evaluate the correlation between COth and COauto in an anesthetized, ventilated piglet hemorrhagic shock (HS) model. The secondary objectives were to evaluate the correlation between COth and CO evaluated by manual measurements of VTI, and the preload-dependency of VTIvaresp.
METHODS: Eighteen piglets were bled until mean arterial pressure reached 40 mm Hg. Controlled hemorrhage was maintained for 30 min before a resuscitation phase. CO was measured by Pulse index Contour Cardiac Output thermodilution methods. At each time of the experiment, three VTI values were measured (min, med, max) and the average value was calculated. COs were calculated by TTE (COmax, COmed, COmin, COave).
RESULTS: For the 204 measures attempted, the success rate was 197 (97%) manually and 122 (60%) automatically (P < 0.01). The correlation coefficients (r) between COth and, respectively, COauto, COave, COmax, COmed, and COmin were: 0.83 (95% CI [0.76; 0.88]; P < 0.01), 0.54 (95% CI [0.43; 0.63]; P < 0.01), 0.43 (95% CI [0.31; 0.54]; P < 0.01), 0.58 (95% CI [0.48; 0.67]; P < 0.01), and 0.52 (95% CI [0.41; 0.62]; P < 0.01).
CONCLUSION: In an experimental model of HS, a new ultrasound tool, COauto, seems better correlated with COth than manual echocardiographic measurements.