肺应变对急性呼吸窘迫综合征犬呼吸力学的影响
该研究用24只健康雄性Beagle犬经静脉注射0.18 mL/kg油酸复制中度ARDS模型,随机分为肺保护性通气(LPV)组和肺应变1.0、1.5、2.0、2.5组,机械通气24小时或至实验终点。结果显示随肺应变增大,潮气量逐渐增加,S1.5、S2.0、S2.5组潮气量显著高于LPV组;实验终点各组静态肺顺应性均较造模前显著下降,S2.0和S2.5组下降率显著大于S1.0和S1.5组。肺应变与静态肺顺应性下降率、平台压和肺应力呈强线性相关;肺应变每增加1,静态肺顺应性下降率增加19.0%,平台压增加10.8 cmH2O,肺应力增加7.4 cmH2O。作者认为肺应变超过1.5时平台压和肺应力显著升高并超出肺保护性通气安全范围,可能进一步加重呼吸机相关性肺损伤。
要点
- 在油酸诱导的中度ARDS犬模型中,肺应变1.5组通气4小时平台压26.2±2.3 cmH2O、肺应力20.5±2.0 cmH2O,均显著高于LPV组(20.2±4.2、16.6±2.5 cmH2O)。
- 肺应变与通气4小时平台压、肺应力及静态肺顺应性下降率呈强线性相关(r分别为0.660、0.539、0.716,均P<0.05)。
- 肺应变每增加1,静态肺顺应性下降率增加19.0%(95%CI 14.6-23.3,P=0.000),平台压增加10.8 cmH2O(95%CI 7.9-13.7,P=0.002),肺应力增加7.4 cmH2O(95%CI 4.7-10.2,P=0.002)。
- S2.0和S2.5组静态肺顺应性下降率分别为48.0±15.0%和54.4±9.5%,显著大于S1.0组25.9±13.7%和S1.5组38.6±8.1%(均P<0.05)。
- 作者认为肺应变2.0和2.5所对应的潮气量可能进一步降低ARDS模型静态肺顺应性,肺应变超过1.5时平台压和肺应力超出肺保护性通气安全范围(分别为35 cmH2O和25 cmH2O)。
适用人群与场景
- 健康雄性Beagle犬经静脉注射0.18 mL/kg油酸复制的中度ARDS模型,随机分为LPV组(n=4)及肺应变1.0、1.5、2.0、2.5组,共24只。
- 机械通气24小时或至实验终点:去甲肾上腺素剂量高于1.4 μg×kg-1×min-1时血压仍低于60 mmHg持续超过30分钟。
处置流程与药物剂量
- LPV组以潮气量6-8 mL/kg通气24小时。
- S1.0、S1.5、S2.0、S2.5组潮气量由肺应变、呼气末正压的容积复张(VPEEP)和功能残气量(FRC)计算得出。
- 实验终点判定:去甲肾上腺素剂量高于1.4 μg×kg-1×min-1时血压仍低于60 mmHg持续超过30分钟。
红旗征与不能漏的情况
- 肺应变超过1.5时平台压和肺应力显著升高,超出肺保护性通气安全范围(平台压35 cmH2O、肺应力25 cmH2O),可能进一步加重呼吸机相关性肺损伤。
研究设计与关键结果
- 动物实验:24只健康雄性Beagle犬经静脉注射0.18 mL/kg油酸复制中度ARDS模型,随机分5组(LPV组n=4,S1.0、S1.5、S2.0、S2.5组),机械通气24小时或至实验终点。
- LPV组潮气量7.1±0.5 mL/kg;S1.0组7.3±1.8 mL/kg与LPV组相近;S1.5、S2.0、S2.5组潮气量分别为13.3±5.5、18.7±5.4、20.1±7.4 mL/kg,均显著高于LPV组(均P<0.05);相同肺应变下个体间潮气量差异大。
- 实验终点各组静态肺顺应性均较造模前显著下降;S2.0和S2.5组下降率分别为48.0±15.0%和54.4±9.5%,显著大于S1.0组25.9±13.7%和S1.5组38.6±8.1%(均P<0.05)。
- 各组造模时平台压和肺应力均显著高于造模前,并随通气时间延长而升高;S1.5组通气4小时平台压26.2±2.3 cmH2O、肺应力20.5±2.0 cmH2O,显著高于LPV组(20.2±4.2、16.6±2.5 cmH2O,均P<0.05),并随肺应变增大持续升高至实验终点。
- 相关分析:肺应变与通气4小时静态肺顺应性下降率、平台压、肺应力呈正相关(r分别为0.716、0.660、0.539,均P<0.05)。
- 线性回归:肺应变每增加1,静态肺顺应性下降率增加19.0%(95%CI 14.6-23.3,P=0.000),平台压增加10.8 cmH2O(95%CI 7.9-13.7,P=0.002),肺应力增加7.4 cmH2O(95%CI 4.7-10.2,P=0.002)。
证据类型、等级与局限
- 动物实验(Beagle犬油酸诱导中度ARDS模型),非临床研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为在动物ARDS模型中,肺应变越大,机械通气时平台压和肺应力越高;肺应变2.0和2.5所对应的潮气量可能进一步降低静态肺顺应性;肺应变超过1.5时平台压和肺应力显著升高并超出肺保护性通气安全范围(35 cmH2O和25 cmH2O),可能进一步加重呼吸机相关性肺损伤。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To explore the effect of lung strain on breathing mechanics in dogs with acute respiratory distress syndrome (ARDS).
METHODS: Twenty-four healthy male Beagle dogs were recruited to reproduce medium ARDS models with venous injection of 0.18 mL/kg oleic acid, and they were randomly assigned to five groups with random numbers table method. In lung protective ventilation (LPV) group (n = 4), the ventilation was supported for 24 hours with tidal volume (VT) at 6-8 mL/kg, and in lung strain 1.0, 1.5, 2.0, 2.5 groups (S1.0, S1.5, S2.0, S2.5 groups), the VT was calculated from lung strain, the volume recruitment by positive end expiratory pressure (VPEEP) and functional residual capacity (FRC). Five groups were given mechanical ventilation for 24 hours or until reaching the end point of the experiment [when the dosage of norepinephrine was higher than 1.4 μg×kg-1×min-1, the blood pressure was still lower than 60 mmHg (1 mmHg = 0.133 kPa) for more than 30 minutes, which was regarded as the end point of the experiment]. Static lung compliance (Cst), airway plateau pressure (Pplat) and lung stress during the experiment were recorded. Linear regression analysis was used to fit the regression equations of lung strain and Cst descending rate, Pplat and lung stress for analyzing their relationships.
RESULTS: The VT of group LPV was (7.1±0.5) mL/kg. With the increase of lung strain, VT was gradually increased. VT of group S1.0 [(7.3±1.8) mL/kg] was similar to group LPV. VT of groups S1.5, S2.0, S2.5 was significantly higher than that of group LPV (mL/kg: 13.3±5.5, 18.7±5.4, 20.1±7.4 vs. 7.1±0.5, all P < 0.05). Moreover, under the same lung strain, the difference in VT among individuals was large. The Cst of each group was decreased significantly at the end of the experiment as compared with that before model reproduction. With the increase of lung strain, the rate of Cst descending was increased, Cst dropped more significantly in groups S2.0 and S2.5 than that in groups S1.0 and S1.5 [(48.0±15.0)%, (54.4±9.5)% vs. (25.9±13.7)%, (38.6±8.1)%, all P < 0.05]. Pplat and pulmonary stress at model reproduction in all groups were significantly higher than those before model reproduction, and they increased with the prolongation of ventilation time. Pplat and lung stress at 4 hours of ventilation in group S1.5 were significantly higher than those in group LPV [Pplat (cmH2O, 1 cmH2O = 0.098 kPa): 26.2±2.3 vs. 20.2±4.2, lung stress (cmH2O): 20.5±2.0 vs. 16.6±2.5, both P < 0.05], and they increased with lung strain increasing till to the end of experiment. It was shown by correlation analysis that lung strain was positively related with Cst descending rate, Pplat and lung stress at 4 hours of ventilation (r value was 0.716, 0.660, 0.539, respectively, all P < 0.05), which indicated a strong linear correlation. It was shown by fitting linear regression analysis that when lung strain increased by 1, Cst descending rate increased by 19.0% [95% confidence interval (95%CI) = 14.6-23.3, P = 0.000], Pplat increased by 10.8 cmH2O (95%CI = 7.9-13.7, P = 0.002), and the lung stress increased by 7.4 cmH2O (95%CI = 4.7-10.2, P = 0.002).
CONCLUSIONS: In animal ARDS models, the larger the lung strain, the higher the Pplat and lung stress during mechanical ventilation, VT originated for lung strain 2.0 and 2.5 may further reduce Cst in ARDS models, when lung strain over 1.5, Pplat and lung stress increased significantly, which exceeded the safe range of LPV (35 cmH2O and 25 cmH2O, respectively), and further aggravated ventilator induced lung injury (VILI).
参考来源
- Liu Q, Guo Y, Shan M, et al. [Effect of lung strain on breathing mechanics in dogs with acute respiratory distress syndrome]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2018. PMID: 30309414. doi:10.3760/cma.j.issn.2095-4352.2018.09.010
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。