文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

通过急诊医疗服务院前筛查早期识别脓毒症

Early recognition of sepsis through emergency medical services pre-hospital screening.
PubMed 文献 · Am J Emerg Med · 2018-10-20
一句话结论前瞻性实施EMS脓毒症筛查工具后,3小时集束化治疗依从性从44.2%升至80%,乳酸和30 mL/kg静脉液体时间缩短。

该研究前瞻性实施急诊医疗服务(EMS)脓毒症筛查工具(2016年6月至11月),与历史对照(2015年8月至2016年3月)比较,通过护士与EMS人员沟通落实方案。筛查135例中20例阳性纳入研究,对照43例。主要终点3小时集束化治疗依从性在EMS工具组显著更高(80% vs 44.2%,p<0.01)。EMS工具组乳酸和30 mL/kg静脉液体的中位时间显著更短,抗生素时间虽更短但差异未达统计学显著(p=0.26)。

要点

  • EMS脓毒症筛查工具组3小时集束化治疗依从性80%,历史对照组44.2%(p<0.01)。
  • EMS工具组乳酸中位时间15分钟(IQR 0-35),对照组46分钟(IQR 34-57),p<0.001。
  • EMS工具组30 mL/kg静脉液体中位时间6.5分钟(IQR 0-38),对照组46分钟(IQR 27.5-72),p<0.001。
  • 抗生素中位时间EMS工具组63.5分钟(IQR 44-92) vs 对照组72分钟(IQR 59.5-112),p=0.26,未达统计学显著。
  • EMS工具组中位SOFA评分5(IQR 2-8)高于对照组2(IQR 1-4),p<0.01。

适用人群与场景

  • 经EMS筛查的脓毒症患者:筛查135例中20例阳性纳入EMS工具组,历史对照43例。
  • 基线 demographics 相似,但EMS工具组中位SOFA评分更高(5 [IQR 2-8] vs 2 [IQR 1-4],p<0.01)。

处置流程与药物剂量

  • 通过护士与EMS人员沟通实施院前脓毒症筛查方案。
  • 3小时集束化治疗包括血培养、乳酸、静脉液体和抗生素。

研究设计与关键结果

  • 研究类型:前瞻性实施EMS脓毒症筛查工具(2016年6月至11月)与历史对照(2015年8月至2016年3月)比较。
  • 主要终点:3小时集束化治疗依从性EMS工具组80% vs 对照组44.2%,p<0.01。
  • 次要终点:乳酸中位时间EMS工具组15分钟(IQR 0-35) vs 对照组46分钟(IQR 34-57),p<0.001。
  • 次要终点:30 mL/kg静脉液体中位时间EMS工具组6.5分钟(IQR 0-38) vs 对照组46分钟(IQR 27.5-72),p<0.001。
  • 次要终点:抗生素中位时间EMS工具组63.5分钟(IQR 44-92) vs 对照组72分钟(IQR 59.5-112),p=0.26,未达统计学显著。

证据类型、等级与局限

  • 证据类型:前瞻性实施研究,与历史对照比较。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 实施EMS脓毒症筛查工具并与护士沟通,可能提高3小时集束化治疗依从性(80% vs 44.2%)。
  • EMS筛查可能缩短乳酸和30 mL/kg静脉液体的时间,抗生素时间差异未达统计学显著。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The Surviving Sepsis Campaign implemented a 3-hour bundle including blood cultures, lactate, intravenous fluids, and antibiotics to improve mortality in sepsis. Though difficult to achieve, bundle compliance is associated with decreased hospital mortality. We predict that the implementation of an Emergency Medical Services (EMS) sepsis screening tool will improve 3-hour bundle compliance.

OBJECTIVES: To determine if pre-hospital sepsis screening improves 3-hour bundle compliance.

METHODS: Prospective implementation of an EMS sepsis screening tool (June 2016-November 2016) was compared to a historical control (August 2015-March 2016). The protocol was facilitated via communication between nurses and EMS personnel. The primary outcome was 3-hour bundle compliance. Secondary outcomes included time to individual bundle components.

RESULTS: Of 135 patients screened, 20 were positive and included in the study, and subsequently compared to 43 control patients. Baseline demographics were similar, except median Sequential Organ Failure Assessment (SOFA) score was higher for the pre-EMS tool group (5 [interquartile range (IQR) 2-8] vs. 2 [IQR 1-4], p < 0.01). Three-hour bundle compliance was significantly higher in the EMS tool group (80% vs. 44.2%, p < 0.01). The pre-EMS tool group had lower median time to lactate (15 [IQR 0-35] vs. 46 min [IQR 34-57], p < 0.001), 30 mL/kg IV fluids (6.5 [IQR 0-38] vs. 46 min [IQR 27.5-72], p < 0.001), and, although not significant, antibiotics (63.5 [IQR 44-92] vs. 72 min [IQR 59.5-112], p = 0.26).

CONCLUSION: Implementation of an EMS sepsis screening tool resulted in improved 3-hour bundle compliance compared to retrospective control.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Borrelli G, Koch E, Sterk E, et al. Early recognition of sepsis through emergency medical services pre-hospital screening. Am J Emerg Med. 2018. PMID: 30366742. doi:10.1016/j.ajem.2018.10.036

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。