文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

早期预警评分能否识别院前环境中的恶化患者?一项系统评价

Can early warning scores identify deteriorating patients in pre-hospital settings? A systematic review.
PubMed 文献 · Resuscitation · 2018-08-29
一句话结论院前极低和极高早期预警评分可区分不太可能和可能恶化的患者,但无研究比较实施前后结局,中间阈值(≥4或5)判别不清。

该系统评价纳入17项预测准确性研究(157,878名参与者,16项在救护车服务、1项在养老院),评估早期预警评分(EWS)在院前环境中预测患者恶化的准确性和有效性。AUC范围从0.50(未报告CI)到0.89(95%CI 0.82, 0.96),短时间框架内死亡或包含死亡和ICU入院的联合结局的AUC通常更高(>0.80)。低分患者在任何时间点死亡都很少,高分患者有恶化风险,但中间阈值(≥4或5)的结果较不明确。无研究比较实施EWS前后的结局,因此没有证据表明使用和不使用EWS的院前环境之间患者结局是否存在差异。

要点

  • 17项预测准确性研究(157,878名参与者)中,AUC范围从0.50(未报告CI)到0.89(95%CI 0.82, 0.96)。
  • 短时间框架内死亡或包含死亡和ICU入院的联合结局,AUC通常更高(>0.80)。
  • 低分患者在任何时间点死亡都很少,高分患者有恶化风险,但中间阈值(≥4或5)结果较不明确。
  • 仅5项研究被判定为低或不明确偏倚风险,其余均为高偏倚风险。
  • 无研究比较实施EWS前后的结局,没有证据表明使用和不使用EWS的院前环境之间患者结局存在差异。

适用人群与场景

  • 院前环境中的患者,包括救护车服务(16项研究)和养老院(1项研究)人群。

诊断标准与关键阈值

  • EWS需聚合三个或以上生理参数才被纳入。

研究设计与关键结果

  • 系统评价纳入17项预测准确性研究,共157,878名参与者,其中16项在救护车服务、1项在养老院。
  • AUC范围从0.50(未报告CI)到0.89(95%CI 0.82, 0.96)。
  • 短时间框架内死亡或包含死亡和ICU入院的联合结局,AUC通常更高(>0.80)。
  • 低分患者在任何时间点死亡都很少,高分患者有恶化风险,中间阈值(≥4或5)结果较不明确。
  • 5项研究被判定为低或不明确偏倚风险,其余均为高偏倚风险。

证据类型、等级与局限

  • 证据类型:系统评价,检索7个数据库至2017年8月,使用QUADAS-2评估研究质量,采用叙述性综合。
  • 5项研究被判定为低或不明确偏倚风险,其余均为高偏倚风险。
  • 无研究比较实施EWS前后的结局,因此没有证据表明使用和不使用EWS的院前环境之间患者结局存在差异。
  • 局限:需要进一步研究来回答该问题并评估院前环境中的EWS。

对床旁实践的改变

  • 院前极低EWS可帮助识别不太可能恶化的患者,极高EWS可帮助识别有恶化风险的患者。
  • 中间阈值(≥4或5)的判别能力较不明确,不能仅凭此阈值做出决策。
  • 目前没有证据表明实施EWS能改变院前患者结局。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the effectiveness and predictive accuracy of early warning scores (EWS) to predict deteriorating patients in pre-hospital settings.

METHODS: Systematic review. Seven databases searched to August 2017. Study quality was assessed using QUADAS-2. A narrative synthesis is presented.

ELIGIBILITY: Studies that evaluated EWS predictive accuracy or that compared outcomes in populations that did or did not use EWS, in any pre-hospital setting were eligible for inclusion. EWS were included if they aggregated three or more physiological parameters.

RESULTS: Seventeen studies (157,878 participants) of predictive accuracy were included (16 in ambulance service and 1 in nursing home). AUCs ranged from 0.50 (CI not reported) to 0.89 (95%CI 0.82, 0.96). AUCs were generally higher (>0.80) for prediction of mortality within short time frames or for combination outcomes that included mortality and ICU admission. Few patients with low scores died at any time point. Patients with high scores were at risk of deterioration. Results were less clear for intermediate thresholds (≥4 or 5). Five studies were judged at low or unclear risk of bias, all others were judged at high risk of bias.

CONCLUSIONS: Very low and high EWS are able to discriminate between patients who are not likely and those who are likely to deteriorate in the pre-hospital setting. No study compared outcomes pre- and post-implementation of EWS so there is no evidence on whether patient outcomes differ between pre-hospital settings that do and do not use EWS. Further studies are required to address this question and to evaluate EWS in pre-hospital settings.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Patel R, Nugawela MD, Edwards HB, et al. Can early warning scores identify deteriorating patients in pre-hospital settings? A systematic review. Resuscitation. 2018. PMID: 30171976. doi:10.1016/j.resuscitation.2018.08.028

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。