文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

空气污染对重症监护病房肺炎患者病情发展的影响:南昌市2014至2016年2454例病例总结

[Influence of air pollution on the development of intensive care unit pneumonia patients: a summary of 2 454 cases from 2014 to 2016 in Nanchang City].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2018-01-01
一句话结论南昌市2014至2016年数据显示,PM2.5与气温和ICU肺炎患者病情显著相关,高浓度PM2.5(200 μg/m3)对ICU肺炎患者的影响存在5天滞后效应(OR=1.45)。

该研究纳入南昌市2014年1月1日至2016年12月31日入住江西省人民医院ICU的2454例患者,分为肺炎组(156例)和非肺炎组(2298例),收集患者一般临床特征及同期南昌市空气污染浓度。采用多元回归模型分析气象因素对ICU肺炎患者病情的影响,用比值比(OR)及95%CI反映空气污染暴露与ICU肺炎患者病情发展的关联强度,并建立分布滞后非线性模型(DLNM)评估空气质量参数的时间滞后效应。结果显示,入组当天PM2.5(OR=1.02,95%CI 1.00-1.03,P<0.05)和气温(OR=0.96,95%CI 0.92-0.98,P<0.05)与ICU肺炎患者显著相关,PM2.5的影响至少持续5天(OR=1.04,95%CI 1.00-1.09,P<0.05),至第7天消失;当PM2.5浓度达200 μg/m3时,其对ICU肺炎患者的影响持续5天(OR=1.45,95%CI 1.07-1.76,P<0.01)。结论认为PM2.5和气温与ICU肺炎患者病情显著相关,高浓度PM2.5对ICU肺炎患者的影响具有滞后效应。

要点

  • 入组当天PM2.5每升高1个单位,ICU肺炎风险OR=1.02(95%CI 1.00-1.03,P<0.05),效应至少持续5天(OR=1.04,95%CI 1.00-1.09,P<0.05),第7天消失。
  • 当PM2.5浓度达200 μg/m3时,对ICU肺炎患者的影响持续5天,OR=1.45(95%CI 1.07-1.76,P<0.01)。
  • 入组当天平均气温与ICU肺炎风险呈负相关,OR=0.96(95%CI 0.92-0.98,P<0.05)。
  • 肺炎组患者年龄总体高于非肺炎组,多为男性,预期病死率和急性生理学与慢性健康状况评分Ⅱ(APACHEⅡ)更高。
  • 肺炎组入组当天平均气温低于非肺炎组,PM2.5和PM10等空气污染物显著高于非肺炎组。

适用人群与场景

  • 2014年1月1日至2016年12月31日居住于南昌市并入住江西省人民医院ICU的患者2454例,按诊断分为肺炎组156例和非肺炎组2298例。

研究设计与关键结果

  • 研究类型为基于2454例ICU患者的观察性分析,比较肺炎组(156例)与非肺炎组(2298例)的临床特征及同期南昌市空气污染浓度。
  • 入组当天PM2.5与ICU肺炎显著相关:OR=1.02(95%CI 1.00-1.03,P<0.05);气温与ICU肺炎显著相关:OR=0.96(95%CI 0.92-0.98,P<0.05)。
  • PM2.5对ICU肺炎患者的影响至少持续5天(OR=1.04,95%CI 1.00-1.09,P<0.05),至第7天消失。
  • 当PM2.5浓度达200 μg/m3时,其对ICU肺炎患者的影响持续5天,OR=1.45(95%CI 1.07-1.76,P<0.01)。
  • 肺炎组年龄总体高于非肺炎组,多为男性,预期病死率和APACHEⅡ评分更高;肺炎组入组当天平均气温低于非肺炎组,PM2.5和PM10等空气污染物显著高于非肺炎组。

证据类型、等级与局限

  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为PM2.5和气温与ICU肺炎患者病情显著相关,高浓度PM2.5对ICU肺炎患者的影响具有滞后效应。
  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To analyze the main characteristics of air pollution in Nanchang City, and discuss the correlation between air pollution exposure (especially PM2.5) and the development of pneumonia related intensive care unit (ICU) patients and their lag effect.

METHODS: 2 454 patients who lived in Nanchang City admitted to ICU of Jiangxi Provincial People's Hospital from January 1st, 2014 to December 31st, 2016 were enrolled. According to the diagnosis, the patients were divided into pneumonia group (156 cases) and non-pneumonia group (2 298 cases). The general clinical characteristics of patients and air pollution concentration in Nanchang in the year between 2014-2016 were collected. Multiple regression model was used to analyze the influence of meteorological factors on the condition of ICU patients associated with pneumonia. Using odds ratio (OR), the correlation intensity of air pollution exposure and pneumonia related ICU patients' development was reflected, and the confidence level of association intensity was reflected by the 95% confidence interval (95%CI). The distribution lag nonlinear model (DLNM) was established to evaluate the effect of air mass parameters on the time lag effect.

RESULTS: The results of air pollution analysis in Nanchang City in the year between 2014-2016 showed that the annual average concentration of carbon monoxide (CO), sulfur dioxide (SO2) and nitrogen dioxide (NO2) was low and maintained at the same level in the year between 2014-2016. The annual average concentration of CO and NO2 increased in the year between 2014-2016, but the average annual concentration of SO2 decreased rapidly in the year between 2014-2016, and the average annual concentration of PM2.5 tended to slow down after the year between 2014-2016. The annual average concentration of PM10 decreased in the year between 2014-2016, but continued to rise in the year between 2014-2016. The annual mean concentration of O3 showed a trend of continuous increase from the year between 2014-2016. The age of pneumonia group was generally higher than that of non-pneumonia group, most of them were male, and had higher expected mortality and acute physiology and chronic health evaluation II (APACHE II) score. The average air temperature in the pneumonia group was lower than that in the non-pneumonia group on the day of entering the group, and the air pollutants such as PM2.5 and PM10 were significantly higher than those in the non-pneumonia group. The analysis of multiple regression models showed that PM2.5 and air temperature were significantly related to patients with ICU pneumonia on the day of entry (PM2.5: OR = 1.02, 95%CI = 1.00-1.03, P < 0.05; air temperature: OR = 0.96, 95%CI = 0.92-0.98, P < 0.05), and the effect of PM2.5 on patients with ICU pneumonia could last for at least 5 days (OR = 1.04, 95%CI = 1.00-1.09, P < 0.05), and the effect disappeared until the 7th day. According to the analysis of the influence of different concentrations of PM2.5 on ICU pneumonia patients, when the PM2.5 concentration reached 200 μg/m3, its effect on ICU pneumonia patients would last for 5 days (OR = 1.45, 95%CI = 1.07-1.76, P < 0.01).

CONCLUSIONS: PM2.5 and air temperature are significantly related to the condition of ICU patients with pneumonia, and the influence of high concentration of PM2.5 on ICU patients with pneumonia has a lag effect.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Xia W, Li T, He H, et al. [Influence of air pollution on the development of intensive care unit pneumonia patients: a summary of 2 454 cases from 2014 to 2016 in Nanchang City]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2018. PMID: 30220277. doi:10.3760/cma.j.issn.2095-4352.2018.08.009

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。