文献速递重症综合管理与镇静镇痛心脑血管急症

远程光电容积描记评估心脏术后重症患者外周循环

Remote Photoplethysmographic Assessment of the Peripheral Circulation in Critical Care Patients Recovering From Cardiac Surgery.
PubMed 文献 · Shock · 2019-01-01
一句话结论在70例心脏术后重症患者中,基于摄像头的远程光电容积描记(cbPPG)信号对血流动力学参数敏感,脉搏压解释个体光脉冲功率变异最高达19.9%。

本研究分析70例心脏术后重症患者的cbPPG记录,离线处理计算心脏射血的光脉冲功率(OPP),同步记录血流动力学数据、图像强度和患者运动,采用混合效应回归模型分析各因素对个体OPP变异和实际OPP值的影响。结果显示平均动脉压、脉压、心率和中心静脉压均能显著解释个体OPP变异,其中脉压解释力最高(19.9%);平均OPP随脉压和平均动脉压升高而显著增加(P均<0.001),随心率的升高而降低(P=0.024);中心静脉压对平均OPP呈双向、非显著影响;图像强度和患者运动显著影响OPP。校正血流动力学协变量和测量条件后,脉压和心率对OPP的影响保持不变,而平均动脉压的影响消失。结论认为cbPPG对重症患者血流动力学参数敏感,是监测外周循环的潜在应用,但其临床价值尚待确定。

要点

  • 在70例心脏术后重症患者中,脉压是解释个体光脉冲功率(OPP)变异的最强血流动力学因素,解释力为19.9%。
  • 平均OPP随脉压和平均动脉压升高而显著增加(P均<0.001),随心率的升高而降低(P=0.024)。
  • 中心静脉压对平均OPP呈双向、非显著影响。
  • 图像强度和患者运动显著影响OPP,是cbPPG监测中需考虑的干扰因素。
  • 校正血流动力学协变量和测量条件后,脉压和心率对OPP的影响保持不变,而平均动脉压的影响消失。

适用人群与场景

  • 心脏术后恢复中的重症监护患者,共70例。

研究设计与关键结果

  • 研究类型为对70例心脏术后重症患者cbPPG记录的分析,信号离线处理计算心脏射血的光脉冲功率(OPP),同步记录血流动力学数据、图像强度和患者运动,采用混合效应回归模型计算各因素对个体OPP变异和实际OPP值的影响。
  • 平均动脉压、脉压、心率和中心静脉压均能显著解释个体OPP变异,其中脉压解释力最高(19.9%)。
  • 平均OPP随脉压和平均动脉压升高而显著增加(P均<0.001),随心率的升高而降低(P=0.024);中心静脉压对平均OPP呈双向、非显著影响。
  • 图像强度和患者运动显著影响OPP。
  • 校正血流动力学协变量和测量条件后,脉压和心率对OPP的影响保持不变,而平均动脉压的影响消失。

证据类型、等级与局限

  • 证据类型为对70例心脏术后重症患者cbPPG记录的分析;原文未报告证据等级。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • cbPPG对重症患者血流动力学参数敏感,是监测外周循环的潜在应用,但其临床价值尚待确定。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

PURPOSE: Camera-based photoplethysmography (cbPPG) remotely detects the volume pulse of cardiac ejection in the peripheral circulation. The cbPPG signal is sourced from the cutaneous microcirculation, yields a 2-dimensional intensity map, and is therefore an interesting monitoring technique. In this study, we investigated whether cbPPG is in general sufficiently sensitive to discern hemodynamic conditions.

METHODS: cbPPG recordings of 70 patients recovering from cardiac surgery were analyzed. Photoplethysmograms were processed offline and the optical pulse power (OPP) of cardiac ejection was calculated. Hemodynamic data, image intensity, and patient movements were recorded synchronously. The effects of hemodynamic parameters and measurement conditions on the patient's individual OPP variability and their actual OPP values were calculated in mixed-effects regression models.

RESULTS: Mean arterial pressure (MAP), pulse pressure (PP), heart rate (HR), and central venous pressure (CVP) significantly explained the individual OPP variability. PP had the highest explanatory power (19.9%). Averaged OPP significantly increased with PP and MAP (P < 0.001, respectively) and decreased with higher HR (P = 0.024). CVP had a 2-directional, nonsignificant effect on averaged OPP. Image intensity and patient movements did significantly affect OPP. After adjustment for hemodynamic covariables and measurement conditions, the effect of PP and HR remained unchanged, whereas that of MAP vanished.

CONCLUSION: cbPPG is sensitive to hemodynamic parameters in critical care patients. It is a potential application for monitoring the peripheral circulation. Its value in a clinical setting has to be determined.

来源:Shock,查看原文。版权归原作者所有。

参考来源

  1. Rasche S, Trumpp A, Schmidt M, et al. Remote Photoplethysmographic Assessment of the Peripheral Circulation in Critical Care Patients Recovering From Cardiac Surgery. Shock. 2019. PMID: 30113390. doi:10.1097/SHK.0000000000001249

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。