升主动脉直径对疑似急性A型主动脉夹层的鉴别价值
本研究为2007至2015年间在整合医疗系统21个急诊科开展的回顾性分析,纳入230例A型主动脉夹层(TAAD)病例和325例对照,均由两名读者在右主肺动脉层面测量平扫CT升主动脉直径,并计算年龄、性别、体表面积标化的Z评分。结果显示,原始与标化升主动脉直径鉴别能力相似(AUC 0.96 vs 0.97,ΔAUC=0.01,p=0.09),原始直径34 mm和Z评分1.84均达100%敏感性,特异度分别为35%(95%CI 29.6%-40.2%)和67%(95%CI 61.7%-72.2%)。作者认为,若经验证,这些数据可能有助于在无法获得、无诊断价值或禁忌行金标准检查的疑似TAAD患者中判断风险。
要点
- 在疑似TAAD患者中,平扫CT升主动脉直径34 mm对TAAD的敏感性为100%,特异度为35%(95%CI 29.6%-40.2%)。
- 年龄、性别、体表面积标化Z评分1.84对TAAD的敏感性为100%,特异度为67%(95%CI 61.7%-72.2%)。
- 原始与标化升主动脉直径鉴别TAAD的AUC分别为0.96和0.97(ΔAUC=0.01,p=0.09),标化后分类有小幅增量改善(NRI=0.30,95%CI 0.13-0.47)。
- TAAD病例与对照的中位升主动脉直径分别为50 mm和35 mm,中位年龄分别为65岁和62岁。
- 作者认为,若经验证,这些数据可能有助于在无法获得、无诊断价值或禁忌行金标准检查的疑似TAAD患者中判断风险。
适用人群与场景
- 2007至2015年间在整合医疗系统21个急诊科因疑似TAAD接受CT主动脉造影评估的患者,包括最终确诊TAAD的病例和未确诊TAAD的对照。
诊断标准与关键阈值
- 平扫CT在右主肺动脉层面测量升主动脉直径,原始直径34 mm对TAAD的敏感性为100%,特异度为35%(95%CI 29.6%-40.2%)。
- 年龄、性别、体表面积标化Z评分1.84对TAAD的敏感性为100%,特异度为67%(95%CI 61.7%-72.2%)。
研究设计与关键结果
- 研究为回顾性分析,纳入230例TAAD病例和325例对照,来自21个急诊科。
- TAAD病例与对照的中位年龄分别为65岁和62岁,中位升主动脉直径分别为50 mm和35 mm。
- 原始与标化升主动脉直径的AUC分别为0.96和0.97(ΔAUC=0.01,p=0.09),NRI为0.30(95%CI 0.13-0.47)。
- 原始升主动脉直径34 mm对TAAD的敏感性为100%,特异度为35%(95%CI 29.6%-40.2%)。
- 标化Z评分1.84对TAAD的敏感性为100%,特异度为67%(95%CI 61.7%-72.2%)。
证据类型、等级与局限
- 证据类型:回顾性分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,若经验证,这些数据可能有助于在无法获得、无诊断价值或禁忌行金标准检查的疑似TAAD患者中判断风险。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: The objective was to determine if ascending aorta (AscAo) diameters measured by noncontrast computed tomography (CT) allow for meaningful discrimination between patients with and without type A aortic dissection (TAAD), ideally with 100% sensitivity.
METHODS: This study was a retrospective analysis of cases of TAAD, as well as controls, undergoing evaluation for TAAD with CT aortography, presenting to 21 emergency departments within an integrated health system between 2007 and 2015. AscAo diameters were determined using axial noncontrast CT images at the level of the right main pulmonary artery by two readers. AscAo diameters were additionally normalized for age, sex, and body surface area (assessed by a Z-score, which is the number of standard deviations between the observed and expected AscAo diameters). Overall model discrimination was assessed using the area under the receiver operating characteristic curve (AUC). Comparative discrimination was assessed using both the change in AUC (∆AUC) and the continuous net reclassification index (NRI).
RESULTS: A total of 230 cases of TAAD and 325 controls were included in the study. The median ages for cases and controls were 65 and 62 years, and the median AscAo diameters were 50 and 35 mm, respectively. The raw and normalized AscAo diameters demonstrated similarly excellent discrimination (AUCs of 0.96 vs. 0.97, respectively; ∆AUC = 0.01, p = 0.09) and an NRI of 0.30 (95% confidence interval [CI] = 0.13-0.47), both indicating small incremental improvements in classification with the use of the normalized AscAo measures. A raw AscAo diameter of 34 mm and a normalized Z-score of 1.84 both yielded 100% sensitivity for TAAD, with respective specificities of 35% (95% CI = 29.6%-40.2%) and 67% (95% CI = 61.7%-72.2%).
CONCLUSIONS: Nearly all patients with TAAD appear to have enlarged AscAo diameters as measured by noncontrast CT, whereas most patients with suspected but absent TAAD have relatively normal AscAo diameters. Both raw and normalized AscAo measures provided relatively comparable discriminatory value. If validated, these data may be useful in adjudicating risk among patients with suspected TAAD in whom a criterion standard test is unavailable, nondiagnostic, or contraindicated.
参考来源
- Mark DG, Davis JA, Hung YY, et al. Discriminatory Value of the Ascending Aorta Diameter in Suspected Acute Type A Aortic Dissection. Acad Emerg Med. 2018. PMID: 30091507. doi:10.1111/acem.13547
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。