实验性心肺复苏中复苏性主动脉腔内球囊阻断:阻断水平至关重要
在27头麻醉猪心搏骤停模型中,7分钟机械按压心肺复苏后随机行REBOA于胸降主动脉心脏水平(Ib区,n=9)、膈肌水平(Ic区,n=9)或不阻断(对照,n=9)。主要结局为复苏期间系统动脉压。Ic区阻断使收缩压从86 mmHg(CI 71-101)升至128 mmHg(CI 107-150,P<0.001),平均压和舒张压亦显著升高且高于Ib区和对照;Ib区阻断对系统血压无显著影响。Ic区动脉乳酸低于对照和Ib区,对照动脉pH下降更多。作者认为Ic区阻断可能更有效,REBOA与更有利的酸碱状态相关,若作为复苏辅助手段需仔细确定阻断水平。
要点
- 猪心搏骤停复苏模型中,Ic区(膈肌水平)REBOA使收缩压从86 mmHg(CI 71-101)升至128 mmHg(CI 107-150,P<0.001)。
- Ic区阻断的平均压和舒张压显著高于Ib区(P=0.04和P=0.02)及对照(P=0.005和P=0.003)。
- Ib区(心脏水平)REBOA对系统动脉压无显著影响。
- Ic区动脉乳酸低于对照(P=0.04)和Ib区(P<0.001);对照动脉pH下降较Ib区和Ic区更多(P=0.004和P=0.005)。
- 作者认为心肺复苏中以REBOA为辅助时,仔细确定主动脉阻断水平可能很重要。
适用人群与场景
- 麻醉猪心搏骤停模型,心肺复苏7分钟后开始REBOA。
处置流程与药物剂量
- 心肺复苏7分钟后,经股动脉置入REBOA球囊,分别置于胸降主动脉心脏水平(Ib区)、膈肌水平(Ic区)或不行阻断(对照)。
研究设计与关键结果
- 动物实验:27头麻醉猪心搏骤停,随机分Ib区(n=9)、Ic区(n=9)和对照(n=9)。
- 主要结局:Ic区收缩压从86 mmHg(CI 71-101)升至128 mmHg(CI 107-150,P<0.001);Ib区对系统血压无显著影响。
- Ic区平均压和舒张压高于Ib区(P=0.04和P=0.02)和对照(P=0.005和P=0.003)。
- 对照动脉pH下降较Ib区和Ic区更多(P=0.004和P=0.005);Ic区乳酸低于对照(P=0.04)和Ib区(P<0.001)。
证据类型、等级与局限
- 证据类型:动物实验(猪心搏骤停模型)。
- 研究经瑞典林雪平地区动物伦理委员会批准(申请编号418)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,若在心肺复苏中使用REBOA作为辅助,仔细确定主动脉阻断水平可能很重要。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
INTRODUCTION: Aortic occlusion during cardiopulmonary resuscitation (CPR) increases systemic arterial pressures. Correct thoracic placement during the resuscitative endovascular balloon occlusion of the aorta (REBOA) may be important for achieving effective CPR.
HYPOTHESIS: The positioning of the REBOA in the thoracic aorta during CPR will affect systemic arterial pressures.
METHODS: Cardiac arrest was induced in 27 anesthetized pigs. After 7 min of CPR with a mechanical compression device, REBOA in the thoracic descending aorta at heart level (zone Ib, REBOA-Ib, n = 9), at diaphragmatic level (zone Ic, REBOA-Ic, n = 9) or no occlusion (control, n = 9) was initiated. The primary outcome was systemic arterial pressures during CPR.
RESULTS: During CPR, REBOA-Ic increased systolic blood pressure from 86 mmHg (confidence interval [CI] 71-101) to 128 mmHg (CI 107-150, P < 0.001). Simultaneously, mean and diastolic blood pressures increased significantly in REBOA-Ic (P < 0.001 and P = 0.006, respectively), and were higher than in REBOA-Ib (P = 0.04 and P = 0.02, respectively) and control (P = 0.005 and P = 0.003, respectively). REBOA-Ib did not significantly affect systemic blood pressures. Arterial pH decreased more in control than in REBOA-Ib and REBOA-Ic after occlusion (P = 0.004 and P = 0.005, respectively). Arterial lactate concentrations were lower in REBOA-Ic compared with control and REBOA-Ib (P = 0.04 and P < 0.001, respectively).
CONCLUSIONS: Thoracic aortic occlusion in zone Ic during CPR may be more effective in increasing systemic arterial pressures than occlusion in zone Ib. REBOA during CPR was found to be associated with a more favorable acid-base status of circulating blood. If REBOA is used as an adjunct in CPR, it may be of importance to carefully determine the aortic occlusion level.The study was performed following approval of the Regional Animal Ethics Committee in Linköping, Sweden (application ID 418).
参考来源
- Dogan EM, Beskow L, Calais F, et al. Resuscitative Endovascular Balloon Occlusion of the Aorta in Experimental Cardiopulmonary Resuscitation: Aortic Occlusion Level Matters. Shock. 2019. PMID: 30067564. doi:10.1097/SHK.0000000000001236
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。