急性心肌梗死合并心脏骤停冠脉血运重建后VA-ECMO成功撤机的预测因素:一项回顾性多中心研究
这项回顾性多中心研究分析了55例急性心肌梗死合并心脏骤停、接受VA-ECMO和PCI的连续患者,评估ECMO启动后48小时内的临床数据,用多因素logistic回归确定成功撤机的独立预测因素。28例(51%)成功撤机,27例(49%)撤机失败。多因素分析显示PCI后TIMI血流分级(P=0.046)、ECMO启动后4小时平均动脉压(P=0.010)和24小时血清乳酸(P=0.015)是成功撤机的独立预测因素。成功撤机组24小时和48小时左心室射血分数显著更高(P=0.014,P=0.025)。作者认为,撤机失败的患者LVEF在48小时内未恢复,应考虑辅助使用其他循环机械装置。
要点
- PCI后TIMI血流分级是VA-ECMO成功撤机的独立预测因素(P=0.046)。
- ECMO启动后4小时平均动脉压是成功撤机的独立预测因素(P=0.010)。
- ECMO启动后24小时血清乳酸是成功撤机的独立预测因素(P=0.015)。
- 成功撤机组24小时和48小时LVEF显著高于撤机失败组(P=0.014,P=0.025)。
- 撤机失败患者LVEF在48小时内未恢复,作者认为应考虑辅助使用其他循环机械装置。
适用人群与场景
- 急性心肌梗死合并心脏骤停、接受VA-ECMO和经皮冠状动脉介入治疗的连续患者。
研究设计与关键结果
- 回顾性多中心研究,纳入55例急性心肌梗死合并心脏骤停接受VA-ECMO和PCI的患者,评估ECMO启动后48小时内临床数据。
- 28例(51%)成功撤机,27例(49%)撤机失败。
- 多因素分析显示PCI后TIMI血流分级(P=0.046)、ECMO启动后4小时平均动脉压(P=0.010)、24小时血清乳酸(P=0.015)是成功撤机的独立预测因素。
- 成功撤机组24小时和48小时LVEF显著更高(P=0.014,P=0.025)。
- 撤机失败患者LVEF在48小时内未恢复。
证据类型、等级与局限
- 证据类型:回顾性多中心研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,对VA-ECMO撤机失败且48小时内LVEF未恢复的患者,应考虑辅助使用其他循环机械装置。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIM: While veno-arterial extracorporeal membrane oxygenation (VA-ECMO) has been utilized to resuscitate and stabilize hemodynamics in patients of acute myocardial infarction (AMI) complicated by cardiac arrest (CA), it is essential to predict the possibility of weaning from ECMO to determine further strategies, including use of ventricular assist device. We aimed to determine predictors of successful weaning from VA-ECMO in the early phase of ECMO treatment.
METHODS: We identified consecutive patients of AMI complicated by CA treated with VA-ECMO and percutaneous coronary intervention (PCI). Clinical data within 48 h after ECMO initiation were assessed and multiple logistic regression analysis was performed to determine independent predictors of weaning outcome.
RESULTS: Fifty-five patients were analyzed. While 28 (51%) patients were successfully weaned from VA-ECMO, 27 (49%) failed to wean. Multivariate analysis identified post-PCI thrombolysis in myocardial infarction (TIMI) flow grade (P = 0.046), mean arterial pressure (MAP) at 4 h after ECMO initiation (P = 0.010), and serum lactate at 24 h (P = 0.015) as independent predictors of successful weaning. Left ventricular ejection fraction (LVEF) at 24 and 48 h was significantly greater in the successful weaning group (P = 0.014, P = 0.025, respectively).
CONCLUSIONS: Successful weaning from VA-ECMO was predicted by post-PCI TIMI flow grade, MAP at 4 h, and serum lactate at 24 h after VA-ECMO initiation in patients of AMI complicated by CA. Furthermore, in patients who failed to wean from ECMO, LVEF did not recover within 48 h. In such patients, adjunctive use of other circulatory mechanical devices must be considered.
参考来源
- Sugiura A, Abe R, Nakayama T, et al. Predictors of Successful Weaning From Veno-Arterial Extracorporeal Membrane Oxygenation After Coronary Revascularization for Acute Myocardial Infarction Complicated by Cardiac Arrest: A Retrospective Multicenter Study. Shock. 2019. PMID: 30080744. doi:10.1097/SHK.0000000000001220
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。