盆腔钝性创伤中CT血管内对比剂外渗界定盆腔血管栓塞需求的局限性:假阳性风险的具体评估
该回顾性研究纳入2010至2015年创伤中心311例严重创伤伴骨盆环骨折患者,评估CT上血管内对比剂外渗(ICE)特征对盆腔经导管动脉栓塞(TAE)需求的预测性能。94例(30%)初始CT有至少一处盆腔ICE;需TAE者aSICE和pSICE显著更大(p=0.001和p=0.035)。ICE表面对盆腔TAE的总体预测能力有限(aSICE AUC 0.76,95%CI 0.64-0.90,p=0.011)或无统计学意义(pSICE和exSICE)。高灵敏度阈值定为aSICE≥20 mm,该阈值下76%为假阳性。假阳性风险因素包括入院收缩压≥90 mm Hg、低输血需求、外渗与复杂骨折接触、外渗与大腹膜后血肿无直接关系。
要点
- 盆腔钝性创伤中动脉期显著ICE(aSICE≥20 mm)不保证需要盆腔TAE,该阈值下76%患者为假阳性。
- 需盆腔TAE者aSICE和pSICE显著大于不需者(p=0.001和p=0.035),但ICE表面总体预测能力有限(aSICE AUC 0.76,95%CI 0.64-0.90,p=0.011;pSICE和exSICE无统计学意义)。
- 假阳性风险因素:入院收缩压≥90 mm Hg(63% vs 20%,p=0.03)、低输血需求(63% vs 10%,p=0.009)、外渗与复杂骨折接触(78% vs 30%,p=0.008)、外渗与大腹膜后血肿无直接关系(100% vs 38%,p<0.001)。
- 作者认为多项补充CT标准有助于识别假阳性风险,以决定适当的盆腔止血操作。
适用人群与场景
- 2010至2015年单中心创伤中心所有严重创伤伴骨盆骨折患者,共311例骨盆环骨折(平均年龄42±19岁;平均损伤严重度评分27±19)。
诊断标准与关键阈值
- 盆腔ICE的CT特征:动脉(aSICE)、门脉表面(pSICE)和延伸(exSICE)解剖关系。
- 高灵敏度阈值定义为aSICE≥20 mm。
研究设计与关键结果
- 回顾性研究,311例严重创伤伴骨盆环骨折患者,94例(30%)初始CT有至少一处盆腔ICE。
- 需盆腔TAE者aSICE和pSICE显著大于不需者(p=0.001和p=0.035)。
- ICE表面对盆腔TAE总体预测能力有限:aSICE的AUC 0.76(95%CI 0.64-0.90),p=0.011;pSICE和exSICE无统计学意义。
- 以aSICE≥20 mm为高灵敏度阈值,76%患者为假阳性。
- 假阳性风险因素:入院收缩压≥90 mm Hg(63% vs 20%,p=0.03)、低输血需求(63% vs 10%,p=0.009)、外渗与复杂骨折接触(78% vs 30%,p=0.008)、外渗与大腹膜后血肿无直接关系(100% vs 38%,p<0.001)。
证据类型、等级与局限
- 治疗性研究,证据等级IV级。
- 局限:原文未报告局限性。
对床旁实践的改变
- 动脉期显著盆腔ICE不保证需要盆腔TAE,aSICE≥20 mm者中76%未需要盆腔TAE,作者认为多项补充CT标准有助于识别假阳性风险以决定适当的盆腔止血操作。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: The objective was to assess the predictive performance of different intravascular contrast extravasation (ICE) characteristics for need for pelvic transarterial embolization (TAE) to determine the risk factors of false positives.
METHODS: A retrospective study was performed in our trauma center between 2010 and 2015. All severe trauma patients with pelvic fracture were included. Pelvic ICE characteristics on computed tomography (CT) scan were studied: arterial (aSICE), portal surface (pSICE), and extension (exSICE) anatomic relationships. The overall predictive performance of ICE surfaces for pelvic TAE was analyzed using receiver operating characteristic curves. The analysis focused on risk factors for false positives.
RESULTS: Among 311 severe trauma patients with pelvic ring fracture (mean age, 42 ± 19 years; mean Injury Severity Score, 27 ± 19), 94 (30%) had at least one pelvic ICE on the initial CT scan. Patients requiring pelvic TAE had significantly larger aSICE and pSICE than others (p = 0.001 and p = 0.035, respectively). The overall ability of ICE surfaces to predict pelvic TAE was modest (aSICE area under the receiver operating characteristic curve, 0.76 [95% confidence interval, 0.64-0.90]; p = 0.011) or nonsignificant (pSICE and exSICE). The high-sensitivity threshold was defined as aSICE 20 mm or more. Using this threshold, 76% of patients were false positives. Risk factors for false positives were admission systolic blood pressure of 90 mm Hg or greater (63% vs 20%; p = 0.03) and low transfusion needs (63% vs 10%; p = 0.009), extravasation in contact with complex bone fracture (78% vs 30%; p = 0.008), or the absence of a direct relationship between extravasation and a large retroperitoneal hematoma (100% vs 38%; p < 0.001).
CONCLUSION: A significant pelvic ICE during the arterial phase does not guarantee the need for pelvic TAE. Three quarters of patients with aSICE of 20 mm or more did not need pelvic TAE. Several complementary CT scan criteria will help to identify this risk of false positives to determine adequate hemostatic pelvic procedures.
LEVEL OF EVIDENCE: Therapeutic study, level IV.
参考来源
- Ramin S, Hermida M, Millet I, et al. Limits of intravascular contrast extravasation on computed tomography scan to define the need for pelvic angioembolization in pelvic blunt trauma: a specific assessment on the risk of false positives. J Trauma Acute Care Surg. 2018. PMID: 29901544. doi:10.1097/TA.0000000000002001