降钙素原作为急诊科脓毒症/脓毒性休克诊断标志物:基于Sepsis-3定义的研究
本研究为回顾性队列研究,纳入急诊就诊时测量降钙素原且最终诊断与感染相关的患者,按Sepsis-3定义分为感染、脓毒症和脓毒性休克。共866例纳入最终分析,其中感染287例、脓毒症470例、脓毒性休克109例。ROC曲线分析显示,诊断脓毒症的最佳 cutoff 为0.41 ng/dL(敏感度74.8%、特异度63.8%、AUC 0.745),脓毒性休克为4.7 ng/dL(敏感度66.1%、特异度79.0%、AUC 0.784),作者定义的「脓毒性休克前期」为2.48 ng/dL(敏感度72.8%、特异度72.8%、AUC 0.781)。作者结论认为降钙素原是根据Sepsis-3定义预测脓毒症或脓毒性休克的可靠生物标志物。
要点
- 866例急诊感染相关患者中,按Sepsis-3定义诊断脓毒症的最佳降钙素原 cutoff 为0.41 ng/dL,敏感度74.8%、特异度63.8%、AUC 0.745。
- 诊断脓毒性休克的最佳 cutoff 为4.7 ng/dL,敏感度66.1%、特异度79.0%、AUC 0.784。
- 作者定义的「脓毒性休克前期」(初始诊断脓毒症后平均动脉压降至65 mmHg以下、对液体复苏无效且急诊期间需用血管升压药)最佳 cutoff 为2.48 ng/dL,敏感度72.8%、特异度72.8%、AUC 0.781。
- 作者结论认为降钙素原是根据Sepsis-3定义预测脓毒症或脓毒性休克的可靠生物标志物。
适用人群与场景
- 急诊就诊时测量降钙素原且最终诊断与感染相关的患者。
诊断标准与关键阈值
- 按Sepsis-3定义将患者分为感染、脓毒症或脓毒性休克。
- 「脓毒性休克前期」定义为:患者初始诊断为脓毒症,随后平均动脉压降至65 mmHg以下、对液体复苏无效,且急诊住院期间需要使用血管升压药。
研究设计与关键结果
- 回顾性队列研究,共866例纳入最终分析,其中感染287例、脓毒症470例、脓毒性休克109例。
- 诊断脓毒症的最佳 cutoff 为0.41 ng/dL,敏感度74.8%、特异度63.8%、AUC 0.745。
- 诊断脓毒性休克的最佳 cutoff 为4.7 ng/dL,敏感度66.1%、特异度79.0%、AUC 0.784。
- 诊断「脓毒性休克前期」的最佳 cutoff 为2.48 ng/dL,敏感度72.8%、特异度72.8%、AUC 0.781。
证据类型、等级与局限
- 证据类型:回顾性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 原文未据此给出推荐。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
INTRODUCTION: The recent definition of sepsis was modified based on a scoring system focused on organ failure (Sepsis-3). It would be a time-consuming process to detect the sepsis patient using Sepsis-3. Procalcitonin (PCT) is a well-known biomarker for diagnosing sepsis/septic shock and monitoring the efficacy of treatment. We conducted a study to verify the predictability of PCT for diagnosing sepsis based on Sepsis-3 definition.
MATERIALS & METHODS: This is a retrospective cohort study. The patients whose PCT was measured on the emergency department (ED) arrival and had final diagnosis related infection were enrolled. The patients were categorized by infection, sepsis, or septic shock followed by Sepsis-3 definition. "Pre-septic shock" was defined when a patient was initially diagnosed with sepsis, following which his/her mean arterial blood pressure decreased to under 65 mmHg refractory to fluid resuscitation and there was need for vasopressor use during ED admission. Receiver operating characteristics (ROC) curve and area under the curve (AUC) analysis were performed to verify sensitivity and specificity of PCT.
RESULTS: 866 patients were enrolled in the final analysis. There are 287 cases of infection, 470 cases of sepsis, and 109 cases of septic shock. An optimal cutoff value for diagnosing sepsis was 0.41 ng/dL (sensitivity: 74.8% and specificity: 63.8%; AUC: 0745), septic shock was 4.7 ng/dL (sensitivity: 66.1% and specificity: 79.0%; AUC: 0.784), and "pre-septic shock" was 2.48 ng/dL (sensitivity: 72.8%, specificity: 72.8%, AUC: 0.781), respectively.
CONCLUSION: PCT is a reliable biomarker to predict sepsis or septic shock according to the Sepsis-3 definitions.
参考来源
- Kim SJ, Hwang SO, Kim YW, et al. Procalcitonin as a diagnostic marker for sepsis/septic shock in the emergency department; a study based on Sepsis-3 definition. Am J Emerg Med. 2018. PMID: 29861371. doi:10.1016/j.ajem.2018.05.047
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。