自动化肺栓塞风险分类与CT肺动脉造影医嘱的指南依从性
本研究在212例急诊接受CTPA的 encounters 中,开发了仅基于结构化电子病历数据的自动化Wells和修订Geneva风险评分版本,将患者分类为「PE可能」或「PE不太可能」,并结合D-二聚体医嘱数据评估指南依从性。自动化Wells和修订Geneva风险分类与人工图表回顾分类相比准确率分别为91.5%和92%。自动化评分计算的指南依从率与人工图表回顾无统计学显著差异(Wells 70.8% vs 75%,p=0.33;修订Geneva 65.6% vs 66%,p=0.92)。结论提示结构化电子病历数据元素自动提取可高精度近似Wells和修订Geneva评分风险分类,结合D-二聚体医嘱数据可在无需人工图表回顾负担的情况下自动评估急诊CTPA医嘱的临床指南依从性。
要点
- 在212例急诊CTPA encounters中,仅用结构化电子病历数据自动计算的Wells和修订Geneva风险分类与人工图表回顾分类相比准确率分别为91.5%和92%。
- 自动化评分评估的指南依从率与人工图表回顾无统计学显著差异:Wells 70.8% vs 75%(p=0.33),修订Geneva 65.6% vs 66%(p=0.92)。
- 自动化方法将患者分类为「PE可能」或「PE不太可能」,并结合D-二聚体医嘱数据判定CTPA医嘱为指南一致或不一致。
- 该方法可在急诊接受CTPA的患者中自动评估指南依从性,无需人工图表回顾。
适用人群与场景
- 急诊科接受CTPA的 encounters(本研究为212例急诊 encounters)。
诊断标准与关键阈值
- 自动化Wells和修订Geneva风险评分将患者分类为「PE可能」或「PE不太可能」。
- 结合D-二聚体医嘱数据将每次 encounter 评估为指南一致或指南不一致。
研究设计与关键结果
- 研究类型为诊断准确性/方法学评估,样本量212例急诊CTPA encounters。
- 自动化Wells和修订Geneva风险分类与人工图表回顾分类相比准确率分别为91.5%和92%。
- 自动化评分计算的指南依从率与人工图表回顾无统计学显著差异:Wells 70.8% vs 75%(p=0.33);修订Geneva 65.6% vs 66%(p=0.92)。
证据类型、等级与局限
- 证据类型:方法学比较研究(自动化结构化数据评分 vs 人工图表回顾)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在急诊接受CTPA的患者中,仅用结构化电子病历数据自动计算的Wells和修订Geneva评分可高精度近似人工图表回顾的风险分类(准确率91.5%和92%)。
- 自动化评分结合D-二聚体医嘱数据可自动评估CTPA医嘱的指南依从性,且与人工图表回顾无统计学显著差异,无需人工图表回顾负担。
指南或共识出处
- Acad Emerg Med
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: The assessment of clinical guideline adherence for the evaluation of pulmonary embolism (PE) via computed tomography pulmonary angiography (CTPA) currently requires either labor-intensive, retrospective chart review or prospective collection of PE risk scores at the time of CTPA order. The recording of clinical data in a structured manner in the electronic health record (EHR) may make it possible to automate the calculation of a patient's PE risk classification and determine whether the CTPA order was guideline concordant.
OBJECTIVES: The objective of this study was to measure the performance of automated, structured data-only versions of the Wells and revised Geneva risk scores in emergency department (ED) encounters during which a CTPA was ordered. The hypothesis was that such an automated method would classify a patient's PE risk with high accuracy compared to manual chart review.
METHODS: We developed automated, structured data-only versions of the Wells and revised Geneva risk scores to classify 212 ED encounters during which a CTPA was performed as "PE likely" or "PE unlikely." We then combined these classifications with D-dimer ordering data to assess each encounter as guideline concordant or discordant. The accuracy of these automated classifications and assessments of guideline concordance were determined by comparing them to classifications and concordance based on the complete Wells and revised Geneva scores derived via abstractor manual chart review.
RESULTS: The automatically derived Wells and revised Geneva risk classifications were 91.5 and 92% accurate compared to the manually determined classifications, respectively. There was no statistically significant difference between guideline adherence calculated by the automated scores compared to manual chart review (Wells, 70.8% vs. 75%, p = 0.33; revised Geneva, 65.6% vs. 66%, p = 0.92).
CONCLUSION: The Wells and revised Geneva score risk classifications can be approximated with high accuracy using automated extraction of structured EHR data elements in patients who received a CTPA. Combining these automated scores with D-dimer ordering data allows for the automated assessment of clinical guideline adherence for CTPA ordering in the ED, without the burden of manual chart review.
参考来源
- Koziatek CA, Simon E, Horwitz LI, et al. Automated Pulmonary Embolism Risk Classification and Guideline Adherence for Computed Tomography Pulmonary Angiography Ordering. Acad Emerg Med. 2018. PMID: 29710413. doi:10.1111/acem.13442
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。