文献速递复苏、休克与脓毒症

院前质量控制复苏中人工心肺复苏与主动加压-减压装置的心电二氧化碳排出量比较:病例系列研究

End-tidal carbon dioxide output in manual cardiopulmonary resuscitation versus active compression-decompression device during prehospital quality controlled resuscitation: a case series study.
PubMed 文献 · Emerg Med J · 2018-05-16
一句话结论病例系列研究提示,以ETCO2为定量指标时,质量控制下的ACD-CPR并不优于质量控制下的人工CPR。

该病例系列研究纳入10例目击性院外心脏骤停患者,在插管并保持恒定通气频率、使用视听反馈除颤器持续质控的条件下,每例交替进行2分钟人工CPR与2分钟主动加压-减压(ACD)CPR。平均CPR时长37(SD 8)分钟;ACD-CPR与人工CPR的平均按压深度分别为76(SD 1.3)mm与71(SD 1.0)mm,平均按压频率分别为100次/分(SD 6.7)与105次/分(SD 4.9)。ETCO2排出量的方法与患者交互作用显著(P<0.001),10例中6例人工CPR的ETCO2排出量更高。作者认为,以ETCO2作为CPR效果的定量指标时,质量控制下的ACD-CPR并不优于质量控制下的人工CPR。

要点

  • 10例目击性院外心脏骤停患者每例交替接受2分钟人工CPR与2分钟ACD-CPR,插管后保持恒定通气频率并以视听反馈除颤器持续质控。
  • ACD-CPR与人工CPR的平均按压深度分别为76(SD 1.3)mm与71(SD 1.0)mm,平均按压频率分别为100次/分(SD 6.7)与105次/分(SD 4.9)。
  • ETCO2排出量的方法与患者交互作用显著(P<0.001),10例中6例人工CPR的ETCO2排出量更高。
  • 平均CPR时长为37(SD 8)分钟,比较在每例患者内部进行以减少病例间混杂。
  • 作者认为,以ETCO2作为CPR效果的定量指标时,质量控制下的ACD-CPR并不优于质量控制下的人工CPR。

适用人群与场景

  • 10例目击性院外心脏骤停(OHCA)患者,均接受插管且CPR期间通气频率保持恒定。

处置流程与药物剂量

  • 每例患者交替进行2分钟人工CPR与2分钟ACD-CPR循环。
  • 患者插管,CPR期间通气频率保持恒定。
  • 使用视听反馈除颤器连续采集CPR质量参数与ETCO2值。
  • ETCO2排出量以2分钟循环的汇总值作为因变量,患者为随机因素、方法为固定效应,采用线性混合模型分析,比较在每例OHCA病例内部进行。

研究设计与关键结果

  • 研究类型为病例系列研究,纳入10例目击性OHCA,每例交替接受2分钟人工CPR与2分钟ACD-CPR。
  • 平均CPR时长为37(SD 8)分钟。
  • ACD-CPR与人工CPR的平均按压深度分别为76(SD 1.3)mm与71(SD 1.0)mm,平均按压频率分别为100次/分(SD 6.7)与105次/分(SD 4.9)。
  • ETCO2排出量的方法与患者交互作用显著(P<0.001)。
  • 10例中6例人工CPR的ETCO2排出量更高。

证据类型、等级与局限

  • 证据类型:病例系列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,以ETCO2作为CPR效果的定量指标时,质量控制下的ACD-CPR并不优于质量控制下的人工CPR。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Active compression-decompression (ACD) devices have enhanced end-tidal carbon dioxide (ETCO2) output in experimental cardiopulmonary resuscitation (CPR) studies. However, the results in out-of-hospital cardiac arrest (OHCA) patients have shown inconsistent outcomes, and earlier studies lacked quality control of CPR attempts. We compared manual CPR with ACD-CPR by measuring ETCO2 output using an audiovisual feedback defibrillator to ensure continuous high quality resuscitation attempts.

METHODS: 10 witnessed OHCAs were resuscitated, rotating a 2 min cycle with manual CPR and a 2 min cycle of ACD-CPR. Patients were intubated and the ventilation rate was held constant during CPR. CPR quality parameters and ETCO2 values were collected continuously with the defibrillator. Differences in ETCO2 output between manual CPR and ACD-CPR were analysed using a linear mixed model where ETCO2 output produced by a summary of the 2 min cycles was included as the dependent variable, the patient as a random factor and method as a fixed effect. These comparisons were made within each OHCA case to minimise confounding factors between the cases.

RESULTS: Mean length of the CPR episodes was 37 (SD 8) min. Mean compression depth was 76 (SD 1.3) mm versus 71 (SD1.0) mm, and mean compression rate was 100 per min (SD 6.7) versus 105 per min (SD 4.9) between ACD-CPR and manual CPR, respectively. For ETCO2 output, the interaction between the method and the patient was significant (P<0.001). ETCO2 output was higher with manual CPR in 6 of the 10 cases.

CONCLUSIONS: This study suggests that quality controlled ACD-CPR is not superior to quality controlled manual CPR when ETCO2 is used as a quantitative measure of CPR effectiveness.

TRIAL REGISTRATION NUMBER: NCT00951704; Results.

来源:Emerg Med J,查看原文。版权归原作者所有。

参考来源

  1. Setälä PA, Virkkunen IT, Kämäräinen AJ, et al. End-tidal carbon dioxide output in manual cardiopulmonary resuscitation versus active compression-decompression device during prehospital quality controlled resuscitation: a case series study. Emerg Med J. 2018. PMID: 29769232. doi:10.1136/emermed-2017-207103

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。