文献速递复苏、休克与脓毒症

利用自动体外除颤器数据分析院外心脏骤停旁观者心肺复苏质量

Analysis of bystander CPR quality during out-of-hospital cardiac arrest using data derived from automated external defibrillators.
PubMed 文献 · Resuscitation · 2018-05-16
一句话结论旁观者心肺复苏质量整体较高,胸外按压分数76%、深度5.3 cm、频率111.2次/分,但第一分钟质量最低,主要因心律分析延迟(平均40.7秒)。

该研究利用复苏结局联盟数据库,纳入100例疑似心源性院外心脏骤停且使用自动体外除颤器并接受旁观者心肺复苏的病例,将自动体外除颤器存储的数据与病例匹配,分析旁观者心肺复苏质量、随时间变化及对2010年复苏质量指南的依从性。结果显示旁观者整体实施高质量心肺复苏:胸外按压分数76%、按压深度5.3 cm、按压频率111.2次/分,除颤前后暂停平均26.8秒。对2010年指南按压频率和深度的依从率分别为66%和55%。心肺复苏质量在第一分钟最低,原因为心律分析延迟(平均40.7秒);在实施电击的病例中,从启动自动体外除颤器到放电的潜伏期为59.2秒。

要点

  • 旁观者整体心肺复苏质量较高:胸外按压分数76%、按压深度5.3 cm、按压频率111.2次/分,高质量心肺复苏维持至复苏前5分钟。
  • 心肺复苏质量在第一分钟最低,原因为心律分析延迟,平均40.7秒。
  • 对2010年复苏指南按压频率和深度的依从率分别为66%和55%。
  • 除颤前后暂停平均26.8秒;实施电击的病例中,从启动自动体外除颤器到放电的潜伏期为59.2秒。
  • 研究纳入100例疑似心源性院外心脏骤停病例,平均年龄62.3岁,75%为男性。

适用人群与场景

  • 疑似心源性院外心脏骤停且接受旁观者心肺复苏并使用自动体外除颤器的病例,共100例,平均年龄62.3岁,75%为男性。

研究设计与关键结果

  • 研究类型为利用复苏结局联盟数据库的病例分析,纳入100例疑似心源性院外心脏骤停且接受旁观者心肺复苏并使用自动体外除颤器的病例,将自动体外除颤器数据与病例匹配后分析旁观者心肺复苏质量。
  • 旁观者整体心肺复苏质量:胸外按压分数76%、按压深度5.3 cm、按压频率111.2次/分。
  • 除颤前后暂停平均26.8秒;实施电击的病例中,从启动自动体外除颤器到放电的潜伏期为59.2秒。
  • 对2010年复苏指南按压频率和深度的依从率分别为66%和55%。
  • 心肺复苏质量在第一分钟最低,原因为心律分析延迟(平均40.7秒)。

证据类型、等级与局限

  • 证据类型:利用复苏结局联盟数据库的病例分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为旁观者实施高质量心肺复苏,对现有复苏指南依从率较高;高质量心肺复苏维持至复苏前5分钟,但第一分钟质量最低。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Little is known regarding the quality of cardiopulmonary resuscitation (CPR) performed by bystanders in out-of-hospital cardiac arrest (OHCA). We sought to determine quality of bystander CPR provided during OHCA using CPR quality data stored by Automated External Defibrillators (AEDs).

METHODS: We used the Resuscitation Outcomes Consortium database to identify OHCA cases of presumed cardiac etiology where an AED was utilized. We then matched AED data to each case identified. AED data was analyzed using manufacturer software in order to determine overall measures of bystander CPR quality, changes in bystander CPR quality over time, and adherence to existing 2010 Resuscitation Quality Guidelines.

RESULTS: 100 cases of OHCA of presumed cardiac etiology involving bystander CPR and with corresponding AED data. Mean age was 62.3 years, and 75% were male. Bystanders demonstrated high-quality CPR over all minutes of resuscitation, with a chest compression fraction of 76%, a compression depth of 5.3 cm, and a compression rate of 111.2 compressions/min. Mean perishock pause was 26.8 s. Adherence rates to 2010 Resuscitation Guidelines for compression rate and depth were found to be 66% and 55%, respectively. CPR quality was lowest in the first minute, resulting from increased delay to rhythm analysis (mean 40.7 s). In cases involving shock delivery, latency from initiation of AED to shock delivery was 59.2 s.

CONCLUSIONS: We found that bystanders perform high-quality CPR, with strong adherence rates to existing Resuscitation Guidelines. High-quality CPR is maintained over the first five minutes of resuscitation, but was lowest in the first minute.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Fernando SM, Vaillancourt C, Morrow S, et al. Analysis of bystander CPR quality during out-of-hospital cardiac arrest using data derived from automated external defibrillators. Resuscitation. 2018. PMID: 29753856. doi:10.1016/j.resuscitation.2018.05.012

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。