文献速递复苏、休克与脓毒症呼吸衰竭与机械通气重症综合管理与镇静镇痛

院前有创通气脓毒性休克患者入ICU时动脉血氧分压的预后价值

Prognosis value of partial arterial oxygen pressure in patients with septic shock subjected to pre-hospital invasive ventilation.
PubMed 文献 · Am J Emerg Med · 2018-04-24
一句话结论院前有创通气脓毒性休克患者入ICU时PaO2>150 mm Hg与28天死亡率独立相关(OR 1.59),作者建议早期调整PaO2以避免高氧毒性。

本研究为单中心回顾性观察研究,纳入77例院前接受有创机械通气的脓毒性休克患者,分析入ICU时PaO2与28天死亡率的关系。存活者入ICU时平均PaO2为153±77 mm Hg,死亡者为202±82 mm Hg。PaO2<100 mm Hg者死亡率为18%,100<PaO2<150 mm Hg者为25%,PaO2>150 mm Hg者为57%。PaO2与28天死亡率显著相关(p=0.04);倾向评分分析(纳入SOFA评分、院前时间、乳酸和院前液体复苏量)后,仅PaO2>150 mm Hg与死亡率独立相关(p=0.02,OR 1.59,95%CI 1.20-2.10)。作者认为应早期调整PaO2以避免高氧毒性,但院前血气分析难以获取,需脉搏血氧饱和度等替代可行措施。

要点

  • 院前有创通气脓毒性休克患者入ICU时PaO2>150 mm Hg与28天死亡率独立相关(OR 1.59,95%CI 1.20-2.10,p=0.02)。
  • 入ICU时PaO2>150 mm Hg者28天死亡率为57%,100<PaO2<150 mm Hg者为25%,PaO2<100 mm Hg者为18%。
  • 存活者入ICU时平均PaO2为153±77 mm Hg,死亡者为202±82 mm Hg。
  • 倾向评分分析纳入SOFA评分、院前时间、乳酸和院前液体复苏量后,仅PaO2>150 mm Hg与28天死亡率独立相关。
  • 作者建议早期调整PaO2以避免高氧毒性,但院前血气分析难以获取,需脉搏血氧饱和度等替代可行措施。

适用人群与场景

  • 院前接受有创机械通气的脓毒性休克患者,入ICU时测量PaO2。
  • 单中心回顾性观察研究,共77例患者。

处置流程与药物剂量

  • 作者指出院前血气分析难以获取,需脉搏血氧饱和度等替代可行措施以改善院前有创通气管理。

研究设计与关键结果

  • 单中心回顾性观察研究,77例院前有创通气脓毒性休克患者,入ICU时测量PaO2,主要终点为28天死亡率。
  • 存活者入ICU时平均PaO2为153±77 mm Hg,死亡者为202±82 mm Hg。
  • PaO2<100 mm Hg者28天死亡率为18%,100<PaO2<150 mm Hg者为25%,PaO2>150 mm Hg者为57%。
  • PaO2与28天死亡率显著相关(p=0.04)。
  • 倾向评分分析(纳入SOFA评分、院前时间、乳酸和院前液体复苏量)后,仅PaO2>150 mm Hg与28天死亡率独立相关(p=0.02,OR 1.59,95%CI 1.20-2.10)。

证据类型、等级与局限

  • 单中心回顾性观察研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,对于院前有创通气的脓毒性休克患者,应早期调整PaO2以避免高氧毒性。
  • 作者指出院前血气分析难以获取,需脉搏血氧饱和度等替代可行措施以改善院前有创通气管理。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: Mechanical ventilation can help improve the prognosis of septic shock. While adequate delivery of oxygen to the tissue is crucial, hyperoxemia may be deleterious. Invasive out-of-hospital ventilation is often promptly performed in life-threatening emergencies. We propose to determine whether the arterial oxygen pressure (PaO2) at the intensive care unit (ICU) admission is associated with mortality in patients with septic shock subjected to pre-hospital mechanical ventilation.

METHODS: We performed a monocentric retrospective observational study on 77 patients. PaO2 was measured at ICU admission. The primary outcome was mortality at day 28 (D28).

RESULTS: Forty-nine (64%) patients were included. The mean PaO2 at ICU admission was 153 ± 77 and 202 ± 82 mm Hg for alive and deceased patients respectively. Mortality concerned 18% of patients for PaO2 < 100, 25% for 100 < PaO2 < 150 and 57% for a PaO2 > 150 mm Hg. PaO2 was significantly associated with mortality at D28 (p = 0.04). Using propensity score analysis including SOFA score, pre-hospital duration, lactate, and prehospital fluid volume expansion, association with mortality at D28 only remained for PaO2 > 150 mm Hg (p = 0.02, OR [CI95] = 1.59 [1.20-2.10]).

CONCLUSIONS: In this study, we report a significant association between hyperoxemia at ICU admission and mortality in patients with septic shock subjected to pre-hospital invasive mechanical ventilation. The early adjustment of the PaO2 should be considered for these patients to avoid the toxic effects of hyperoxemia. However, blood gas analysis is hard to get in a prehospital setting. Consequently, alternative and feasible measures are needed, such as pulse oximetry, to improve the management of pre-hospital invasive ventilation.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Jouffroy R, Saade A, Saint Martin LC, et al. Prognosis value of partial arterial oxygen pressure in patients with septic shock subjected to pre-hospital invasive ventilation. Am J Emerg Med. 2018. PMID: 29709397. doi:10.1016/j.ajem.2018.04.050

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。