文献速递复苏、休克与脓毒症

腹部提压心肺复苏术可改善心脏骤停患者的复苏效果

[Interposed abdominal pulling-pressing cardiopulmonary resuscitation improve the resuscitation effect for patients with cardiac arrest].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2018-01-01
一句话结论对心脏骤停患者,在常规胸外按压基础上加用腹部提压心肺复苏(IAPP-CPR)可提高自主循环恢复率、复苏成功率及生存出院率。

该前瞻性研究纳入2013年7月至2017年12月山东矿业集团中心医院急诊科收治的122例心脏骤停患者,按入院顺序分为标准心肺复苏组(S-CPR,n=62)和IAPP-CPR组(n=60)。IAPP-CPR组在常规胸外按压基础上,于放松期行腹部提拉与按压,幅度4-5 cm,频率100次/min,提拉与按压时间比1:1。结果显示,IAPP-CPR组复苏后30分钟心率、平均动脉压、动脉血氧分压及呼气末二氧化碳分压均显著高于S-CPR组,动脉血二氧化碳分压和乳酸显著降低;自主循环恢复时间更短,自主循环恢复率、复苏成功率、24小时生存率及生存出院率均显著高于S-CPR组。Logistic回归显示PaO2、PaCO2和PETCO2是复苏成功的影响因素,ROC曲线显示PaCO2和PETCO2预测价值较好。

要点

  • IAPP-CPR组自主循环恢复率61.7%(37/60)vs S-CPR组43.5%(27/62),复苏成功率40.0%(24/60)vs 21.0%(13/62),均P<0.05。
  • IAPP-CPR组24小时生存率46.7%(28/60)vs S-CPR组29.0%(18/62),生存出院率20.0%(12/60)vs 11.3%(7/62),均P<0.05。
  • IAPP-CPR组自主循环恢复时间6.3±1.8分钟 vs S-CPR组11.2±1.4分钟,P<0.05。
  • 复苏后30分钟IAPP-CPR组PETCO2 45.5±9.6 mmHg vs S-CPR组31.8±8.2 mmHg,PaCO2 46.7±6.2 mmHg vs 57.9±9.5 mmHg,均P<0.05。
  • PaCO2预测复苏成功的AUC为0.93,切点46.7 mmHg时敏感度92.0%、特异度94.3%;PETCO2的AUC为0.92,切点48.8 mmHg时敏感度88.0%、特异度94.3%。

适用人群与场景

  • 2013年7月至2017年12月山东矿业集团中心医院急诊科收治的心脏骤停患者,共122例,按入院顺序分组。

处置流程与药物剂量

  • S-CPR组:胸外心脏按压、开放气道、气管插管、机械通气、常规药物复苏,发现心室颤动时除颤。
  • IAPP-CPR组:在常规胸外按压基础上,于放松期行腹部提拉与按压,幅度4-5 cm,频率100次/min,提拉与按压时间比1:1。

研究设计与关键结果

  • 研究类型:前瞻性研究;样本量122例(S-CPR组n=62,IAPP-CPR组n=60);单中心(山东矿业集团中心医院急诊科);人群为心脏骤停患者。
  • 干预与对照:IAPP-CPR组在常规胸外按压基础上加用腹部提拉按压 vs S-CPR组常规心肺复苏。
  • 主要终点:IAPP-CPR组自主循环恢复率61.7%(37/60)vs S-CPR组43.5%(27/62),复苏成功率40.0%(24/60)vs 21.0%(13/62),均P<0.05。
  • 关键次要终点:IAPP-CPR组自主循环恢复时间6.3±1.8分钟 vs S-CPR组11.2±1.4分钟;24小时生存率46.7%(28/60)vs 29.0%(18/62);生存出院率20.0%(12/60)vs 11.3%(7/62),均P<0.05。
  • 复苏后30分钟指标:IAPP-CPR组 vs S-CPR组,心率66.3±11.5次/min vs 53.1±12.6次/min,平均动脉压65.4±6.5 mmHg vs 53.2±5.4 mmHg,PaO2 77.7±11.8 mmHg vs 61.8±14.3 mmHg,PETCO2 45.5±9.6 mmHg vs 31.8±8.2 mmHg,PaCO2 46.7±6.2 mmHg vs 57.9±9.5 mmHg,乳酸2.1±1.5 mmol/L vs 4.4±2.2 mmol/L,均P<0.05。
  • Logistic回归:PaO2为影响复苏成功的因素(β=-3.76,OR=0.23,95%CI 0.12-0.86,P=0.031);PaCO2(β=1.41,OR=4.09,95%CI 1.70-9.82,P=0.002);PETCO2(β=0.78,OR=2.18,95%CI 1.42-3.35,P=0.000)。
  • ROC曲线:PaCO2预测复苏成功的AUC为0.93,切点46.7 mmHg时敏感度92.0%、特异度94.3%;PETCO2的AUC为0.92,切点48.8 mmHg时敏感度88.0%、特异度94.3%。

证据类型、等级与局限

  • 证据类型:前瞻性研究;局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,与S-CPR组相比,IAPP-CPR组可获得更好的血流动力学和肺通气效果,并显著提高自主循环恢复率和复苏成功率,对心脏骤停患者有明显临床价值。
  • PaO2、PaCO2和PETCO2是影响心肺复苏成功的因素,其中PaCO2和PETCO2对预测复苏成功有较大价值(PaCO2切点46.7 mmHg,PETCO2切点48.8 mmHg)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To study the impact of interposed abdominal pulling-pressing cardiopulmonary resuscitation (IAPP-CPR) for patients with cardiac arrest (CA).

METHODS: A prospective study was conducted. A total of 122 CA patients admitted to Department of Emergency of Shandong Provincial Mining Industry Group Company Central Hospital from July 2013 to December 2017 were enrolled. They were divided into standard cardiopulmonary resuscitation (S-CPR) group (n = 62) and IAPP-CPR group (n = 60) according to order of admission. The patients in S-CPR group received external cardiac compression, open airway, endotracheal intubation, mechanical ventilation, routine drug rescue, and defibrillation when ventricular fibrillation was found. And the patients in IAPP-CPR group received the IAPP-CPR on the basis of the routine chest compression. During the relaxation period, the patients were subjected to abdominal lifting and compressing with amplitude of 4-5 cm, frequency of 100 times/min, and the time ratio of lifting to compressing was 1:1. The data of demographics and clinical signs of patients were collected. The markers of respiratory and circulatory performance of all patients after CPR were determined. The rates of restoration of spontaneous circulation (ROSC), successful resuscitation, and the prognosis were recorded. With the success of CRP as the dependent variable, the factors with statistical significance showed by univariate analysis were used as the independent variable to carry out two classification Logistic regression analysis for screening the influence factors of CPR success. Receiver operating characteristic (ROC) curve was plotted to analyze the predictive value of various factors on the success of CPR.

RESULTS: 122 patients were enrolled in the analysis. Compared with the S-CPR group, heart rate (HR), mean arterial pressure (MAP), arterial partial pressure of oxygen (PaO2), and end-tidal carbon dioxide partial pressure (PETCO2) were significantly increased at 30 minutes after CPR in IAPP-CPR group [HR (bpm): 66.3±11.5 vs. 53.1±12.6, MAP (mmHg, 1 mmHg = 0.133 kPa): 65.4±6.5 vs. 53.2±5.4, PaO2 (mmHg): 77.7±11.8 vs. 61.8±14.3, PETCO2 (mmHg): 45.5±9.6 vs. 31.8±8.2, all P < 0.05], and arterial partial pressure of carbon dioxide (PaCO2) and lactic acid (Lac) were significantly lowered [PaCO2 (mmHg): 46.7±6.2 vs. 57.9±9.5, Lac (mmol/L): 2.1±1.5 vs. 4.4±2.2, both P < 0.05]. The time of CA to ROSC in IAPP-CPR group was significantly shorter than that in S-CPR group (minutes: 6.3±1.8 vs. 11.2±1.4, P < 0.05), the ROSC rate and CPR success rate were significantly higher than those in S-CPR group [ROSC rate: 61.7% (37/60) vs. 43.5% (27/62), CPR success rate: 40.0% (24/60) vs. 21.0% (13/62), both P < 0.05], and 24-hour survival rate and survival and discharge rate of patients were significantly higher than those in the S-CPR group [24-hour survival rate: 46.7% (28/60) vs. 29.0% (18/62), survival and discharge rate: 20.0% (12/60) vs. 11.3% (7/62), both P < 0.05]. Logistic regression analysis showed that PaO2, PaCO2 and PETCO2 were the factors that affect the success of CPR [PaO2: β= -3.76, odds ratio (OR) = 0.23, 95% confidence interval (95%CI) = 0.12-0.86, P = 0.031; PaCO2: β= 1.41, OR = 4.09, 95%CI = 1.70-9.82, P = 0.002, PETCO2: β= 0.78, OR = 2.18, 95%CI = 1.42-3.35, P = 0.000]. ROC curve analysis showed that the above three factors had good predictive value for the success of CPR. The predictive value of PaCO2 and PETCO2 were better, the area under ROC curve (AUC) was 0.93 and 0.92, respectively, when the cut-off values was 46.7 mmHg and 48.8 mmHg, the sensitivity was 92.0%, 88.0%, respectively, and the specificity was both 94.3%.

CONCLUSIONS: PaO2, PaCO2 and PETCO2 are the factors that influence the success of CPR. PaCO2 and PETCO2 have great value in predicting the success of CPR. Compared with the S-CPR group, IAPP-CPR group results in better hemodynamic and pulmonary ventilation effects, and remarkably improve ROSC and successful resuscitation. IAPP-CPR has obvious clinical value for CA patients.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Wang D, Feng X, Han Y, et al. [Interposed abdominal pulling-pressing cardiopulmonary resuscitation improve the resuscitation effect for patients with cardiac arrest]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2018. PMID: 29764553. doi:10.3760/cma.j.issn.2095-4352.2018.05.014

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。