文献速递呼吸衰竭与机械通气心脑血管急症重症综合管理与镇静镇痛

心脏骤停患者机械通气实践及目标温度管理的影响:TTM试验亚组研究

Practice of mechanical ventilation in cardiac arrest patients and effects of targeted temperature management: A substudy of the targeted temperature management trial.
PubMed 文献 · Resuscitation · 2018-05-12
一句话结论心脏骤停后多数患者采用保护性通气(潮气量≤8 ml/kg PBW、低驱动压),高呼吸频率与28天死亡率独立相关;33°C较36°C降低呼气末CO2并增加肺泡死腔分数。

该研究为TTM试验亚组,纳入950例TTM患者中567例有机械通气数据的心脏病因心脏骤停昏迷幸存者,随机分为33°C(TTM33)和36°C(TTM36)两组。在TTM前、TTM结束时(复温前)和复温后三个时间点采集机械通气数据。结果显示TTM结束时中位潮气量7.7 ml/kg PBW(6.4-8.7),60%患者潮气量≤8 ml/kg PBW,中位PEEP 7.7 cmH2O(6.4-8.7),平均驱动压14.6 cmH2O(±4.3),中位FiO2 0.35(0.30-0.45)。多因素分析显示呼吸频率增加与28天死亡率独立相关。TTM33较TTM36降低呼气末CO2(Pgroup=0.0003)并增加肺泡死腔分数(Pgroup=0.003),而PCO2和呼吸分钟通气量两组相似。

要点

  • TTM结束时60%患者潮气量≤8 ml/kg PBW,中位潮气量7.7 ml/kg PBW(6.4-8.7),多数采用保护性通气。
  • 多因素分析显示呼吸频率增加与28天死亡率独立相关。
  • TTM33较TTM36降低呼气末CO2(Pgroup=0.0003)并增加肺泡死腔分数(Pgroup=0.003)。
  • TTM33与TTM36的PCO2水平和呼吸分钟通气量相似。
  • TTM结束时中位PEEP 7.7 cmH2O(6.4-8.7),平均驱动压14.6 cmH2O(±4.3),中位FiO2 0.35(0.30-0.45)。

适用人群与场景

  • 心脏病因心脏骤停的昏迷幸存者,来自TTM试验,随机接受33°C或36°C目标温度管理;567例有机械通气数据。

研究设计与关键结果

  • 研究类型为TTM试验亚组研究,950例TTM患者中567例有机械通气数据;81%为男性,平均(SD)年龄64(12)岁。
  • TTM结束时中位潮气量7.7 ml/kg PBW(6.4-8.7),60%患者潮气量≤8 ml/kg PBW;中位PEEP 7.7 cmH2O(6.4-8.7);平均驱动压14.6 cmH2O(±4.3);中位FiO2 0.35(0.30-0.45)。
  • 多因素分析显示呼吸频率增加与28天死亡率独立相关。
  • TTM33较TTM36降低呼气末CO2(Pgroup=0.0003)并增加肺泡死腔分数(Pgroup=0.003),PCO2水平和呼吸分钟通气量两组相似。

证据类型、等级与局限

  • 证据类型:TTM试验亚组研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为心脏骤停后多数患者采用保护性通气设置,包括低潮气量和低驱动压;高呼吸频率与死亡率相关。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIMS: Mechanical ventilation practices in patients with cardiac arrest are not well described. Also, the effect of temperature on mechanical ventilation settings is not known. The aims of this study were 1) to describe practice of mechanical ventilation and its relation with outcome 2) to determine effects of different target temperatures strategies (33 °C versus 36 °C) on mechanical ventilation settings.

METHODS: This is a substudy of the TTM-trial in which unconscious survivors of a cardiac arrest due to a cardiac cause were randomized to two TTM strategies, 33 °C (TTM33) and 36 °C (TTM36). Mechanical ventilation data were obtained at three time points: 1) before TTM; 2) at the end of TTM (before rewarming) and 3) after rewarming. Logistic regression was used to determine an association between mechanical ventilation variables and outcome. Repeated-measures mixed modelling was performed to determine the effect of TTM on ventilation settings.

RESULTS: Mechanical ventilation data was available for 567 of the 950 TTM patients. Of these, 81% was male with a mean (SD) age of 64 (12) years. At the end of TTM median tidal volume was 7.7 ml/kg predicted body weight (PBW)(6.4-8.7) and 60% of patients were ventilated with a tidal volume ≤ 8 ml/kg PBW. Median PEEP was 7.7cmH2O (6.4-8.7) and mean driving pressure was 14.6 cmH2O (±4.3). The median FiO2 fraction was 0.35 (0.30-0.45). Multivariate analysis showed an independent relationship between increased respiratory rate and 28-day mortality. TTM33 resulted in lower end-tidal CO2 (Pgroup = 0.0003) and higher alveolar dead space fraction (Pgroup = 0.003) compared to TTM36, while PCO2 levels and respiratory minute volume were similar between groups.

CONCLUSIONS: In the majority of the cardiac arrest patients, protective ventilation settings are applied, including low tidal volumes and driving pressures. High respiratory rate was associated with mortality. TTM33 results in lower end-tidal CO2 levels and a higher alveolar dead space fraction compared to TTTM36.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Harmon MBA, van Meenen DMP, van der Veen ALIP, et al. Practice of mechanical ventilation in cardiac arrest patients and effects of targeted temperature management: A substudy of the targeted temperature management trial. Resuscitation. 2018. PMID: 29763713. doi:10.1016/j.resuscitation.2018.04.040

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。