文献速递重症综合管理与镇静镇痛

危重症患者桡动脉导管失功与血管内血栓的关系:一项巢式病例对照研究

Impact of intravascular thrombosis on failure of radial arterial catheters in critically ill patients: a nested case-control study.
PubMed 文献 · Intensive Care Med · 2018-04-02
一句话结论桡动脉导管失功多无管腔内阻塞,但与导管尖端前方血管内血栓强烈相关(OR 36.52),动脉采血频率是可干预的预测因素。

该研究在ICU前瞻性队列中开展非匹配病例对照分析,旨在明确危重症成人桡动脉导管失功是否与血管内血栓相关。导管失功发生率25.5%(200例中,584导管日,发生率87/1000导管日),中位通畅时间13.1天。病例组50例中42例(84.0%)超声发现导管尖端前方血管内血栓,对照组139例中24例(17.3%)。多变量logistic回归显示血栓(OR 36.52,95%CI 12.86-103.74)、女性(OR 3.45,95%CI 1.32-9.05)、动脉采血频率增加(OR 1.20,95%CI 1.04-1.38)与失功概率升高相关,血小板减少则降低失功概率(OR 0.28,95%CI 0.10-0.78)。拔管后仅15.7%的失功导管见管腔内纤维蛋白沉积,无一完全闭塞。

要点

  • 桡动脉导管失功发生率为25.5%(200例中,584导管日,发生率87/1000导管日),中位通畅时间13.1天。
  • 失功病例中84.0%(42/50)超声见导管尖端前方血管内血栓,对照组仅17.3%(24/139)。
  • 多变量分析中血管内血栓与导管失功独立相关(OR 36.52,95%CI 12.86-103.74)。
  • 女性(OR 3.45,95%CI 1.32-9.05)和动脉采血频率增加(OR 1.20,95%CI 1.04-1.38)与失功概率升高相关,血小板减少与失功概率降低相关(OR 0.28,95%CI 0.10-0.78)。
  • 拔管后仅15.7%的失功导管见管腔内纤维蛋白沉积,无一完全闭塞,提示失功机制可能非管腔内阻塞。

适用人群与场景

  • ICU收治的危重症成人患者,均留置桡动脉导管。

研究设计与关键结果

  • 研究类型:非匹配病例对照研究,嵌套于ICU前瞻性队列;样本量200例,584导管日;病例为导管失功者(50例),对照为导管通畅至拔除或随访28天者(139例)。
  • 主要结局:导管失功发生率25.5%(200例中),发生率87/1000导管日,中位通畅时间13.1天。
  • 血管内血栓(导管尖端前方)在病例组84.0%(42/50)vs 对照组17.3%(24/139)。
  • 多变量logistic回归:血管内血栓OR 36.52(95%CI 12.86-103.74);女性OR 3.45(95%CI 1.32-9.05);动脉采血频率OR 1.20(95%CI 1.04-1.38);血小板减少OR 0.28(95%CI 0.10-0.78)。
  • 拔管后镜检:15.7%的失功导管见管腔内纤维蛋白沉积,无一完全闭塞。

证据类型、等级与局限

  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为动脉采血频率是最具干预潜力的预测因素;对桡动脉导管失功的危重症患者,应考虑到血管内血栓可能,而非仅归因于管腔内阻塞。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

PURPOSE: The patency of arterial catheters is essential for reliable invasive blood pressure monitoring. We sought to determine whether radial catheter failures were associated with intravascular thrombosis in critically ill adult patients.

METHODS: This unmatched case-control study was conducted within a prospective cohort of patients admitted to an intensive care unit. The arterial catheter failure was the main outcome, which identified cases. Controls were patients with patent catheter until removal or 28 days of follow-up. The prevalence of intravascular thrombosis in cases and controls was determined by ultrasonography of the cannulated radial artery. Assessors were blinded to clinical findings. Failing catheters were removed and examined microscopically.

RESULTS: Catheter failures occurred in 25.5% of 200 patients during 584 catheter-days (incidence rate, 87/1000 catheter-days). The median patency duration was 13.1 days. An intravascular thrombosis located in front of the catheter tip was diagnosed in 42 of 50 cases (84.0%) and 24 of 139 controls (17.3%). In multivariable logistic regression analysis, the probability of catheter failure was higher in patients with intravascular thrombosis [odds ratio (OR), 36.52; 95% confidence interval (CI), 12.86-103.74] and females (OR, 3.45; 95% CI 1.32-9.05), increased proportionally to arterial blood sampling frequency (OR, 1.20; 95% CI 1.04-1.38), and decreased in thrombocytopenia (OR, 0.28; 95% CI 0.10-0.78). After removal, 15.7% of failing catheters had some luminal fibrin deposits, but none were occluded.

CONCLUSIONS: Most failing radial arterial catheters had no luminal obstruction, but were associated with an intravascular thrombosis. Among predictive factors, arterial blood sampling frequency is the most susceptible to intervention.

来源:Intensive Care Med,查看原文。版权归原作者所有。

参考来源

  1. Fleury Y, Arroyo D, Couchepin C, et al. Impact of intravascular thrombosis on failure of radial arterial catheters in critically ill patients: a nested case-control study. Intensive Care Med. 2018. PMID: 29610936. doi:10.1007/s00134-018-5149-1

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。