文献速递儿科与产科急症

产房预设心电图电极以更早检测新生儿心率

Presetting ECG electrodes for earlier heart rate detection in the delivery room.
PubMed 文献 · Resuscitation · 2018-03-31
一句话结论产房采用预设心电图电极法可较脉搏血氧仪更早获得新生儿心率,1分钟内未检出率分别为30%与54%。

本研究在产房新生儿复苏场景中,将心电图电极于分娩前预设并贴于婴儿胸背部,比较心电图(ECG)与脉搏血氧仪(POX)检出心率的时间。共纳入334名婴儿,其中49名胎龄<31周。总体心率检出中位时间ECG为29秒(IQR 5,60),显著短于POX的60秒(IQR 45,120)(p<0.001);<31周婴儿中ECG为10秒(IQR 2,40),POX为60秒(IQR 30,120)(p<0.001)。1分钟内未检出心率者ECG为30%、POX为54%、任一设备为20%。结论认为该电极应用方法比脉搏血氧仪更有效地为新生儿团队提供及时心率信息。

要点

  • 总体334名婴儿中,ECG检出心率中位时间29秒(IQR 5,60)显著短于POX的60秒(IQR 45,120)(p<0.001)。
  • 胎龄<31周婴儿中,ECG检出心率中位时间10秒(IQR 2,40)显著短于POX的60秒(IQR 30,120)(p<0.001)。
  • 1分钟内未检出心率者:ECG为30%,POX为54%,任一设备为20%。
  • 方法为分娩前预设ECG电极,贴于婴儿胸背部,用于产房新生儿复苏时心率监测。

适用人群与场景

  • 产房分娩的新生儿,共334名婴儿,其中49名胎龄<31周。

处置流程与药物剂量

  • 分娩前预设心电图电极,贴于婴儿胸背部,用于产房新生儿复苏时心率监测。

研究设计与关键结果

  • 研究类型为在产房新生儿复苏中比较ECG与POX检出心率时间的研究,共纳入334名婴儿,其中49名胎龄<31周。
  • 总体心率检出中位时间ECG为29秒(IQR 5,60),POX为60秒(IQR 45,120),ECG显著更短(p<0.001)。
  • 胎龄<31周婴儿中,ECG检出心率中位时间为10秒(IQR 2,40),POX为60秒(IQR 30,120),ECG显著更短(p<0.001)。
  • 1分钟内未检出心率者:ECG为30%,POX为54%,任一设备为20%。

证据类型、等级与局限

  • 证据类型:研究论文(产房新生儿复苏中比较ECG与POX检出心率时间的研究)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在产房采用该研究方法的电极应用比脉搏血氧仪更有效地为新生儿团队提供及时心率信息,该信息是采取适当复苏动作所必需的。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: To determine whether heart rate (HR) could be detected earlier than by pulse oximeter (POX), using a novel method of application of electrocardiogram (ECG) electrodes during neonatal resuscitation in the delivery room.

METHODS: ECG electrodes were set before delivery to be applied to the back of infants' thorax. Time to detect HR was recorded as soon as a numerical HR along with a recognizable and persistent QRS complex was observed on ECG monitor (HRECG) and a plethysmographic waveform was seen on POX monitor (HRPOX).

RESULTS: Out of 334 infants, 49 were <31 weeks of gestational age. Overall, the median (interquartile range, IQR) time to detect HRECG was significantly shorter [29 (5, 60) seconds] than time by POX [60 (45,120) seconds], (p < 0.001). Similarly, in <31-week infants, the median (IQR) time to detect HRECG was 10 (2, 40) seconds compared to 60 (30,120) seconds by POX, (p < 0.001). Failure to have HR detected by 1 minute occurred in 30%, 54% and 20% of infants by ECG, POX and either of the devices, respectively.

CONCLUSION: In the delivery room, electrodes applied by the study method are more effective than pulse oximetry in providing the neonatal team with timely HR information that is necessary for proper resuscitative actions.

来源:Resuscitation,查看原文。版权归原作者所有。