文献速递呼吸衰竭与机械通气儿科与产科急症

儿童机械通气潮气量计算时体重选择重要吗:基于FVC的假设

Does Size Matter When Calculating the "Correct" Tidal Volume for Pediatric Mechanical Ventilation?: A Hypothesis Based on FVC.
PubMed 文献 · Chest · 2018-04-22
一句话结论儿童按实测体重与预测体重标准化的FVC差异显著,作者认为取两者中较低值设定潮气量可能最具肺保护性。

背景:成人机械通气推荐按预测体重标准化潮气量,但儿童常按实测体重通气。本研究为回顾性分析,纳入两个数据集的儿童肺功能检查,比较按实测体重与预测体重计算的FVC(mL/kg)。数据集一来自加拿大健康措施调查的5,394例6至19岁肺功能检查,按实测体重的FVC中位数从最低BMI z评分组的81.4 mL/kg降至最高BMI z评分组的51.7 mL/kg,而按预测体重的FVC随BMI z评分组升高略增。数据集二为儿童医院8,472例6至20岁肺功能检查,按实测体重的FVC中位数亦从69.4降至37.6 mL/kg。作者认为肥胖儿童肺容积反映其按身高预测的体重,低或正常BMI儿童肺容积反映实测体重,提示取实测与预测体重中较低者设定潮气量可能最具肺保护性。

要点

  • 数据集一中按实测体重的FVC中位数从最低BMI z评分组81.4 mL/kg降至最高BMI z评分组51.7 mL/kg,而按预测体重的FVC随BMI z评分组升高略增。
  • 数据集二中按实测体重的FVC中位数随BMI z评分组升高从69.4降至37.6 mL/kg。
  • 肥胖儿童肺容积反映其按身高预测的体重,低或正常BMI儿童肺容积反映实测体重。
  • 作者认为取实测与预测体重中较低者设定潮气量可能最具肺保护性。

适用人群与场景

  • 数据集一:6至19岁接受肺功能检查的患者,来自加拿大健康措施调查。
  • 数据集二:6至20岁在独立儿童医院接受肺功能检查的患者。

研究设计与关键结果

  • 研究类型:回顾性分析,纳入两个数据集的儿童肺功能检查;数据集一5,394例,数据集二8,472例。
  • 数据集一按实测体重的FVC中位数从最低BMI z评分组81.4 mL/kg降至最高BMI z评分组51.7 mL/kg,按预测体重的FVC随BMI z评分组升高略增。
  • 数据集二按实测体重的FVC中位数随BMI z评分组升高从69.4降至37.6 mL/kg。
  • 结论:按实测体重与预测体重标准化时FVC差异显著;肥胖儿童肺容积反映按身高预测的体重,低或正常BMI儿童肺容积反映实测体重。

证据类型、等级与局限

  • 证据类型:回顾性分析,基于两个数据集的肺功能检查。
  • 作者结论:取实测与预测体重中较低者设定潮气量可能最具肺保护性。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,儿童机械通气设定潮气量时取实测与预测体重中较低者可能最具肺保护性。
  • 肥胖儿童肺容积反映按身高预测的体重,低或正常BMI儿童肺容积反映实测体重。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Tidal volumes standardized to predicted body weight are recommended for adult mechanical ventilation, but children are frequently ventilated by using measured body weight. The goal of this study was to examine the difference in FVC (in milliliters per kilogram [mL/kg]) by using measured body weight compared with predicted body weight in children.

METHODS: This retrospective analysis included outpatient pulmonary function tests (PFTs) from two datasets. Dataset one included 6- to 19-year-old patients undergoing PFTs from the nationally representative Canadian Health Measures Survey. Dataset two included 6- to 20-year-old patients undergoing PFTs at a freestanding children's hospital. FVC mL/kg values were analyzed against BMI z scores to show changes in FVC vs BMI between measured and predicted weight.

RESULTS: Dataset one included 5,394 PFTs from the Canadian survey. FVC from measured weight decreased as the BMI z score group increased. The median FVC from measured weight was 81.4 mL/kg in the lowest BMI z score group and 51.7 mL/kg in the highest BMI z score group. FVC from predicted weight increased slightly with increasing BMI z score group. Dataset two included 8,472 patient PFTs from clinical measurement. A decline in median FVC from measured weight (from 69.4 to 37.6 mL/kg) as BMI z score group increased was also seen.

CONCLUSIONS: FVC differs significantly when standardizing to measured weight vs predicted weight. Obese children have lung volumes reflecting their predicted body weight from height. Children with low or normal BMI have lung volumes reflecting measured body weight. These findings suggest that targeting tidal volume by using the lower of measured and predicted body weights would be the most lung-protective strategy.

来源:Chest,查看原文。版权归原作者所有。

参考来源

  1. Kim GJ, Newth CJL, Khemani RG, et al. Does Size Matter When Calculating the "Correct" Tidal Volume for Pediatric Mechanical Ventilation?: A Hypothesis Based on FVC. Chest. 2018. PMID: 29684318. doi:10.1016/j.chest.2018.04.015

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。