脑电图、体感诱发电位与脑CT多模态联合预测心脏骤停后早期不良预后
该研究纳入273例心脏骤停复苏后患者,其中183例在24小时内完成EEG、SEP和脑CT检查。以6个月随访时死亡或无反应觉醒状态为不良结局,采用脑功能分类(CPC)评估。双侧皮层SEP缺失/缺失-病理性(AA/AP)预测不良结局敏感性58.5%,灰质/白质比值<1.21敏感性50.4%,等电位/爆发抑制EEG模式敏感性43%。任一不良预后模式存在时敏感性升至71.5%,两种模式同时存在时敏感性48%,三种模式均存在时敏感性降至23%。联合三种模态可提高敏感性并保持特异性。
要点
- 心脏骤停复苏后24小时内应联合EEG、SEP和脑CT进行多模态预后评估,任一不良模式存在即可将不良结局预测敏感性提升至71.5%(特异性100%)。
- 双侧皮层SEP缺失/缺失-病理性(AA/AP)单独预测6个月不良结局敏感性58.5%,灰质/白质比值<1.21敏感性50.4%,等电位/爆发抑制EEG模式敏感性43%。
- 两种不良预后模式同时存在时敏感性为48%,三种模式均存在时敏感性降至23%,提示多模态联合并非模式越多敏感性越高。
- 该研究人群中未撤除生命支持治疗,联合评估可在维持100%特异性的前提下提高不良结局预测敏感性。
适用人群与场景
- 心脏骤停后成功复苏的患者,且在复苏后24小时内可获取EEG、SEP和脑CT检查。
- 研究队列中生命支持治疗从未被撤除。
诊断标准与关键阈值
- EEG模式按美国临床神经生理学会(American Clinical Neurophysiological Society)术语分类,等电位/爆发抑制模式视为不良预后模式。
- SEP按每半球皮层反应分级,双侧皮层反应缺失/缺失-病理性(AA/AP)视为不良预后模式。
- 脑CT评估灰质/白质(GM/WM)比值,<1.21视为不良预后模式。
- 不良结局定义为6个月随访时死亡或无反应觉醒状态,采用脑功能分类(CPC)评估。
研究设计与关键结果
- 研究类型为队列研究,纳入273例心脏骤停复苏后患者,其中183例(67%)在24小时内完成EEG、SEP和脑CT检查。
- 双侧皮层SEP缺失/缺失-病理性(AA/AP)预测不良结局敏感性58.5%。
- 灰质/白质比值<1.21预测不良结局敏感性50.4%。
- 等电位/爆发抑制EEG模式预测不良结局敏感性43%。
- 任一不良预后模式存在时,不良结局预测敏感性升至71.5%。
- 两种不良预后模式同时存在时敏感性48%,三种模式均存在时敏感性降至23%。
- 所有不良预后模式的特异性均为100%。
证据类型、等级与局限
- 证据类型:队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,联合EEG、SEP和脑CT可提高不良结局预测敏感性并保持特异性,可在心脏骤停复苏后24小时内用于早期预后评估。
- 该研究人群中生命支持治疗从未被撤除,联合评估结果用于预后判断时的临床决策需结合这一背景。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
INTRODUCTION: Prognosticating outcome after cardiac arrest(CA) requires a multimodal approach. However, evidence regarding combinations of methods is limited. We evaluated whether the combination of electroencephalography(EEG), somatosensory evoked potentials(SEPs) and brain computed tomography(CT) could predict poor outcome.
METHODS: We screened our database regarding patients successfully resuscitated after CA, for whom EEG, SEPs and brain CT were available within 24 h. EEG patterns were classified according to American Clinical Neurophysiological Society terminology; SEPs were graded accounting for the cortical responses of each hemisphere; and the grey matter/white matter(GM/WM) ratio was evaluated by brain CT. EEG patterns, SEP findings and GM/WM ratio (with a specificity of 100%) were, individually and in combination, related to poor outcome (death/unresponsive wakefulness state) at 6-month follow-up, using the cerebral performance categories(CPC).
RESULTS: EEG, SEPs and brain CT were available in 183/273(67%) patients. Bilateral absent/absent-pathologic(AA/AP) cortical SEPs predicted a poor outcome with a sensitivity of 58.5%. A GM/WM ratio <1.21 predicted a poor outcome with a sensitivity of 50.4%. Isoelectric/burst-suppression EEG patterns predicted a poor outcome with a sensitivity of 43%. If at least one of these poor prognostic patterns was present, sensitivity for an ominous outcome increased to 71.5%. If, in the same subject, two poor prognostic patterns were simultaneously present, sensitivity was 48%. If all three poor prognostic patterns were present, sensitivity decreased by up to 23%.
CONCLUSION: In this population, in which life-sustaining treatments were never suspended, the combination of EEG, SEPs and brain CT improved the sensitivity, maintaining the specificity of poor outcome prediction.
参考来源
- Scarpino M, Lanzo G, Lolli F, et al. Neurophysiological and neuroradiological multimodal approach for early poor outcome prediction after cardiac arrest. Resuscitation. 2018. PMID: 29679698. doi:10.1016/j.resuscitation.2018.04.016
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。