文献速递中毒与环境急症儿科与产科急症

一氧化碳相关事件监测——对相关疾病和伤害预防的启示,2005-2014年

Surveillance of carbon monoxide-related incidents - Implications for prevention of related illnesses and injuries, 2005-2014.
PubMed 文献 · Am J Emerg Med · 2018-02-13
一句话结论2005-2014年17州监测显示1795起CO事件中897起有人员受伤,3414名伤者78%以上需住院或院前治疗、4.3%死亡,住所与教育设施为主要地点。

该分析汇总2005-2014年17个州参加的两项有毒物质释放急性监测项目数据,评估一氧化碳(CO)事件相关伤害。10年间各州识别1795起CO事件,其中897起有人员受伤,共3414名CO伤者。伤者中61.0%为一般公众、27.7%为雇员、7.6%为学生、2.2%为急救人员;78%以上需住院或院前治疗,4.3%死亡。受伤人数最多地点为住宅或公寓(39.9%),其次为教育设施(10.0%),教育设施每起事件受伤人数比例高(16.3%)。最常见CO来源为暖通空调系统、发电机和机动车辆,设备故障是多数事件的主要促成因素。各州已用这些数据评估CO中毒趋势并开展针对性公共卫生宣教,监测数据有助于制定新政策或支持现有政策。

要点

  • 2005-2014年17州共识别1795起CO事件,其中897起有人员受伤,共3414名CO伤者。
  • 3414名CO伤者中78%以上需住院或院前治疗,4.3%死亡。
  • 伤者构成:一般公众61.0%、雇员27.7%、学生7.6%、急救人员2.2%。
  • 受伤人数最多地点为住宅或公寓(39.9%),教育设施次之(10.0%),教育设施每起事件受伤人数比例为16.3%。
  • 最常见CO来源为暖通空调系统、发电机和机动车辆,设备故障是多数事件的主要促成因素。

适用人群与场景

  • 2005-2014年参与两项有毒物质释放急性监测项目的17个州的CO事件相关受伤人员,包括一般公众、雇员、学生和急救人员。

研究设计与关键结果

  • 研究类型为基于17个州急性有害物质释放监测项目2005-2014年数据的监测分析,共识别1795起CO事件,其中897起有人员受伤。
  • 3414名CO伤者中,一般公众占61.0%,雇员占27.7%,学生占7.6%,急救人员占2.2%。
  • 78%以上的CO伤者需要住院或院前治疗,4.3%死亡。
  • 受伤人数最多的地点为住宅或公寓(39.9%),其次为教育设施(10.0%);教育设施每起事件受伤人数比例为16.3%。
  • 最常见的三种CO来源为暖通空调系统、发电机和机动车辆;设备故障是多数CO事件的主要促成因素。

证据类型、等级与局限

  • 证据类型为监测数据分析;原文未报告局限性。

对床旁实践的改变

  • 各州已利用这些监测数据评估CO中毒趋势并开展针对性公共卫生宣教。
  • 监测数据可用于制定新政策或支持现有政策,例如将CO中毒列为州级法定报告疾病,以及要求所有学校和住房安装CO报警器。
  • 公共卫生部门需要持续关注CO的来源和原因,以帮助减少相关伤害和死亡。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Carbon monoxide (CO) is an insidious gas responsible for approximately 21,000 emergency department visits, 2300 hospitalizations, and 500 deaths in the United States annually. We analyzed 10 combined years of data from two Agency for Toxic Substances and Disease Registry acute hazardous substance release surveillance programs to evaluate CO incident-related injuries.

METHODS: Seventeen states participated in these programs during 2005-2014.

RESULTS: In those 10years, the states identified 1795 CO incidents. Our analysis focused on 897 CO incidents having injured persons. Of the 3414 CO injured people, 61.0% were classified as general public, 27.7% were employees, 7.6% were students, and 2.2% were first responders. More than 78% of CO injured people required hospital or pre-hospital treatment and 4.3% died. The location for most injured people (39.9%) were homes or apartments, followed by educational facilities (10.0%). Educational services had a high number of people injured per incident (16.3%). The three most common sources of CO were heating, ventilation, and air conditioning systems; generators; and motor vehicles. Equipment failure was the primary contributing factor for most CO incidents.

CONCLUSIONS: States have used the data to evaluate trends in CO poisoning and develop targeted public health outreach. Surveillance data are useful for setting new policies or supporting existing policy such as making CO poisoning a reportable condition at the state level and requiring CO alarms in all schools and housing. Public health needs to remain vigilant to the sources and causes of CO to help reduce this injury and death.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Mukhopadhyay S, Hirsch A, Etienne S, et al. Surveillance of carbon monoxide-related incidents - Implications for prevention of related illnesses and injuries, 2005-2014. Am J Emerg Med. 2018. PMID: 29534918. doi:10.1016/j.ajem.2018.02.011

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。