文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

慢性阻塞性肺疾病患者间接测热法与预测能量估算的差异分析

[Analysis of the difference between indirect calorimetry and predicted energy estimation in patients with chronic obstructive pulmonary disease].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2018-01-01
一句话结论COPD机械通气患者中预测能量估算与间接测热法总体一致性较好,但APACHE II评分越高偏差越大,作者建议高APACHE II评分患者用间接测热法确定能量目标值。

该前瞻性队列研究纳入2016年1至12月杭州市富阳区第一人民医院ICU收治的26例慢性阻塞性肺疾病(COPD)机械通气患者,分别用间接测热法(IC)和预测能量估算计算能量值。IC测得的能量目标值显著高于预测能量估算值(7079.3±1213.4 kJ vs. 6527.0±949.8 kJ,P<0.01),Bland-Altman分析显示两法总体一致性相当好。按IC值偏离预测值程度分组,能量偏差组(>15%)IC值显著高于预测值(7711.1±1125.5 kJ vs. 6556.3±907.9 kJ,P<0.01),能量接近组(≤15%)两法无显著差异。多因素Logistic回归显示APACHE II评分是能量评估偏差的独立危险因素(OR=1.403,95%CI 1.019-1.932,P=0.038)。作者建议高APACHE II评分COPD患者用IC确定能量目标值。

要点

  • COPD机械通气患者IC测得能量目标值显著高于预测能量估算值(7079.3±1213.4 kJ vs. 6527.0±949.8 kJ,P<0.01)。
  • Bland-Altman分析显示预测能量估算与IC总体一致性相当好。
  • 能量偏差组(IC偏离预测值>15%)IC值显著高于预测值(7711.1±1125.5 kJ vs. 6556.3±907.9 kJ,P<0.01)。
  • APACHE II评分是IC与预测能量估算偏差的独立危险因素(OR=1.403,95%CI 1.019-1.932,P=0.038)。
  • APACHE II评分每增加1分,能量偏差增加2.0 kJ(β=0.476,95%CI 0.004-0.956,P=0.047)。

适用人群与场景

  • 2016年1至12月杭州市富阳区第一人民医院ICU收治的26例慢性阻塞性肺疾病机械通气患者。

研究设计与关键结果

  • 前瞻性队列研究,纳入26例COPD机械通气患者,分别用间接测热法与预测能量估算计算能量值。
  • IC能量目标值显著高于预测能量估算值(7079.3±1213.4 kJ vs. 6527.0±949.8 kJ,P<0.01)。
  • Bland-Altman分析显示预测能量估算与IC总体一致性相当好。
  • 能量接近组14例(IC偏离预测值≤15%),能量偏差组12例(IC偏离预测值>15%);两组性别、年龄、BMI、COPD类型、APACHE II评分无显著差异。
  • 能量偏差组IC值显著高于预测值(7711.1±1125.5 kJ vs. 6556.3±907.9 kJ,P<0.01);能量接近组两法无显著差异(6539.6±1037.6 kJ vs. 6501.9±1016.7 kJ,P>0.05)。
  • 多因素Logistic回归显示APACHE II评分是能量评估偏差的独立危险因素(OR=1.403,95%CI 1.019-1.932,P=0.038)。
  • 多因素线性回归显示APACHE II评分每增加1分,能量偏差增加2.0 kJ(β=0.476,95%CI 0.004-0.956,P=0.047)。

证据类型、等级与局限

  • 证据类型:前瞻性队列研究。
  • 作者结论:COPD患者预测能量估算与IC测得的静息能量消耗相关性良好;APACHE II评分是能量评估偏差的独立危险因素;作者建议高APACHE II评分患者用IC确定能量目标值。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • COPD机械通气患者中预测能量估算与IC总体一致性相当好,但APACHE II评分较高者偏差增大,作者建议此类患者用IC确定能量目标值。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To analyze the difference between indirect calorimetry (IC) and predicted energy estimation in patients with chronic obstructive pulmonary disease (COPD), and its possible factors affecting the difference, to provide reasonable energy supply basis for COPD patients.

METHODS: A prospective cohort study was conducted. Twenty-six patients with COPD undergoing mechanical ventilation (MV) admitted to intensive care unit (ICU) of Hangzhou City Fuyang District First People's Hospital in Zhejiang Province from January to December in 2016 were enrolled. The energy values of patients were calculated by IC and predicted energy estimation, respectively. According to the degree of IC values deviating from the predicted energy estimation, the patients were divided into energy approaching group (IC values deviating from the empirical energy estimation ≤15%) and energy deviation group (IC values deviating from the empirical energy estimation > 15%). Bland-Altman diagram was drawn, and the consistency of the energy target values assessing by two methods was analyzed. The factors influencing the energy value deviation of the two measuring methods were screened by the multivariate Logistic regression and linear regression analysis.

RESULTS: Twenty-six patients were enrolled in the final analysis. The energy target value of IC was significantly higher than that of predicted energy estimation (kJ: 7 079.3±1 213.4 vs. 6 527.0±949.8), and the difference between two values was statistically significant (P < 0.01). Bland-Altman heterogeneity analysis showed that the overall consistency of the energy values between the predicted energy estimation and IC was quite good. There were 14 patients in energy approaching group, and 12 in energy deviation group. There was no significant difference in gender, age, body mass index (BMI), type of COPD, or acute physiology and chronic health evaluation II (APACHE II) score between the two groups. In energy deviation group, the IC value of patients was significantly higher than predicted energy estimation (kJ: 7 711.1±1 125.5 vs. 6 556.3±907.9, P < 0.01). However, in energy approaching group, there was no significant difference between the energy values of IC and predicted energy estimation (kJ: 6 539.6±1 037.6 vs. 6 501.9±1 016.7, P > 0.05). Multivariate Logistic regression analysis showed that APACHE II score was an independent risk factor inducing the deviation of energy evaluation between IC and predicted energy estimation [odds ratio (OR) = 1.403, 95% confidence interval (95%CI) = 1.019-1.932, P = 0.038]. Multivariate linear regression analysis showed that the APACHE II score increased by 1, and the energy deviation increased by 2.0 kJ (β = 0.476, 95%CI = 0.004-0.956, P = 0.047).

CONCLUSIONS: For patients with COPD, there was a good correlation between predicted energy estimation and the resting energy expenditure measured by IC. APACHE II score was an independent risk factor inducing the deviation of energy evaluation between IC and predicted energy estimation. It is suggested that the target value of energy should be determined by IC for patients with high APACHE II score.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Chen Q, Tang W, Shao X, et al. [Analysis of the difference between indirect calorimetry and predicted energy estimation in patients with chronic obstructive pulmonary disease]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2018. PMID: 29519286. doi:10.3760/cma.j.issn.2095-4352.2018.03.013

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。