文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

无ARDS的ICU机械通气患者中可能可调节的呼吸变量与结局的关系:PRoVENT二次分析

Potentially modifiable respiratory variables contributing to outcome in ICU patients without ARDS: a secondary analysis of PRoVENT.
PubMed 文献 · Ann Intensive Care · 2018-03-21
一句话结论在无ARDS的ICU机械通气患者中,较高的最大气道压(Pmax)与更高的院内死亡率独立相关,而潮气量大小在存活与死亡组间相似。

PRoVENT为国际多中心前瞻性队列研究,连续纳入有创机械通气患者,预设二次分析探讨与死亡率相关的因素,主要终点为全因院内死亡。共纳入935例患者,院内死亡率为21%。与死亡患者相比,存活患者根据「肺损伤预测评分」的ARDS风险更低,接受的最大气道压、驱动压、呼气末正压和FiO2水平更低,而潮气量大小两组相似。多变量分析显示较高的最大气道压是与院内死亡相关的可能可调节通气变量;驱动压未独立相关,但仅343例有可靠驱动压值。

要点

  • 935例无ARDS的ICU机械通气患者中,院内死亡率为21%。
  • 存活患者接受的最大气道压、驱动压、呼气末正压和FiO2水平低于死亡患者,潮气量大小两组相似。
  • 多变量分析显示较高的最大气道压(Pmax)是与院内死亡独立相关的可能可调节通气变量。
  • 驱动压未独立相关,但仅343例患者有可靠的驱动压数值。
  • 与非可调节因素相关的院内死亡包括高龄、免疫抑制、较高的非肺序贯器官衰竭评分、较低脉搏血氧饱和度、较高心率和功能依赖。

适用人群与场景

  • 国际多中心前瞻性队列中连续纳入的有创机械通气患者,因非ARDS原因接受机械通气。

研究设计与关键结果

  • 研究类型为国际多中心前瞻性队列研究的预设二次分析,共纳入935例患者,主要终点为全因院内死亡。
  • 院内死亡率为21%。
  • 与死亡患者相比,存活患者根据「肺损伤预测评分」的ARDS风险更低,接受的最大气道压、驱动压、呼气末正压和FiO2水平更低,潮气量大小两组相似。
  • 多变量分析显示较高的最大气道压(Pmax)是与院内死亡相关的可能可调节通气变量。
  • 驱动压未独立与院内死亡相关,但仅343例患者有可靠的驱动压数值。
  • 与非可调节因素相关的院内死亡包括较高年龄、存在免疫抑制、较高的非肺序贯器官衰竭评估评分、较低的脉搏血氧饱和度读数、较高的心率和功能依赖。

证据类型、等级与局限

  • 证据类型为国际多中心前瞻性队列研究的预设二次分析。
  • 局限:驱动压的可靠数值仅343例患者可用。

对床旁实践的改变

  • 作者认为较高的最大气道压(Pmax)是与无ARDS的ICU机械通气患者院内死亡独立相关的可能可调节通气变量。
  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The majority of critically ill patients do not suffer from acute respiratory distress syndrome (ARDS). To improve the treatment of these patients, we aimed to identify potentially modifiable factors associated with outcome of these patients.

METHODS: The PRoVENT was an international, multicenter, prospective cohort study of consecutive patients under invasive mechanical ventilatory support. A predefined secondary analysis was to examine factors associated with mortality. The primary endpoint was all-cause in-hospital mortality.

RESULTS: 935 Patients were included. In-hospital mortality was 21%. Compared to patients who died, patients who survived had a lower risk of ARDS according to the 'Lung Injury Prediction Score' and received lower maximum airway pressure (Pmax), driving pressure (ΔP), positive end-expiratory pressure, and FiO2 levels. Tidal volume size was similar between the groups. Higher Pmax was a potentially modifiable ventilatory variable associated with in-hospital mortality in multivariable analyses. ΔP was not independently associated with in-hospital mortality, but reliable values for ΔP were available for 343 patients only. Non-modifiable factors associated with in-hospital mortality were older age, presence of immunosuppression, higher non-pulmonary sequential organ failure assessment scores, lower pulse oximetry readings, higher heart rates, and functional dependence.

CONCLUSIONS: Higher Pmax was independently associated with higher in-hospital mortality in mechanically ventilated critically ill patients under mechanical ventilatory support for reasons other than ARDS. Trial Registration ClinicalTrials.gov (NCT01868321).

来源:Ann Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Simonis FD, Barbas CSV, Artigas-Raventós A, et al. Potentially modifiable respiratory variables contributing to outcome in ICU patients without ARDS: a secondary analysis of PRoVENT. Ann Intensive Care. 2018. PMID: 29564726. doi:10.1186/s13613-018-0385-7

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。