基于临床医生节律判读的心肺复苏胸外按压伪差去除效果评估
该研究共使用819段心电图,每段含两个连续10秒间期(一个无伪差间期和一个被心肺复苏伪差污染的间期),经自适应滤波器去除伪差后随机拆分,由四名急诊医生独立判读节律,以无伪差间期的判读为金标准。各医生与金标准的一致性为中等(κ=0.41-0.64),敏感度64.3%-95.0%、特异度70.0%-95.9%;四名医生多数决策(DPR)的一致性为较高度(κ=0.64,95%CI 0.62-0.66),敏感度90.6%、特异度85.6%。与商用除颤建议算法(SAA)相比,SAA一致性为一般(κ=0.33,95%CI 0.31-0.35),敏感度90.3%、特异度66.4%。作者认为临床医生表现优于SAA,但特异度仍低于美国心脏协会推荐标准,目视判读滤波后心电图不够可靠且医生间差异大,采用多名医生共识决策可显著改善结果。
要点
- 四名急诊医生多数决策判读滤波后心电图与金标准一致性κ=0.64(95%CI 0.62-0.66),敏感度90.6%、特异度85.6%。
- 各医生单独判读一致性仅中等(κ=0.41-0.64),敏感度64.3%-95.0%、特异度70.0%-95.9%,医生间差异大。
- 商用除颤建议算法一致性一般(κ=0.33,95%CI 0.31-0.35),敏感度90.3%、特异度66.4%,低于医生多数决策。
- 作者认为临床医生目视判读滤波后心电图不够可靠,特异度仍低于美国心脏协会推荐标准。
- 作者认为采用多名临床医生共识决策可显著改善判读结果。
适用人群与场景
- 研究使用819段心电图,每段含两个连续10秒间期,一个无伪差间期和一个被心肺复苏伪差污染的间期。
- 判读者为四名急诊医生。
诊断标准与关键阈值
- 以无伪差间期的节律判读作为金标准,评估滤波后间期的判读准确性。
研究设计与关键结果
- 研究类型为诊断准确性评估,共使用819段心电图,由四名急诊医生独立判读节律。
- 各医生与金标准的一致性为中等,κ=0.41-0.64;敏感度64.3%-95.0%,特异度70.0%-95.9%。
- 四名医生多数决策(DPR)与金标准的一致性为较高度,κ=0.64(95%CI 0.62-0.66),敏感度90.6%,特异度85.6%。
- 商用除颤建议算法(SAA)与金标准的一致性为一般,κ=0.33(95%CI 0.31-0.35),敏感度90.3%,特异度66.4%。
证据类型、等级与局限
- 证据类型为诊断准确性评估。
- 作者指出临床医生目视判读滤波后心电图不够可靠且医生间差异大,特异度仍低于美国心脏协会推荐标准;采用多名医生共识决策可显著改善结果。
- 局限:原文未报告局限性
对床旁实践的改变
- 作者认为临床医生对滤波后心电图的目视判读不够可靠,单独判读时与金标准一致性仅中等且医生间差异大。
- 作者认为采用多名临床医生共识决策可显著改善判读结果,多数决策一致性κ=0.64、敏感度90.6%、特异度85.6%。
- 作者指出临床医生判读的特异度仍低于美国心脏协会推荐标准。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIM: To evaluate the performance of a state-of-the-art cardiopulmonary resuscitation (CPR) artefact suppression method by assessing to what extent the filtered electrocardiogram (ECG) can be correctly diagnosed by emergency medicine doctors.
METHODS: A total of 819 ECG segments were used. Each segment contained two consecutive 10 s intervals, an artefact free interval and an interval corrupted by CPR artefacts. Each ECG segment was digitally processed to remove CPR artefacts using an adaptive filter. Each ECG segment was split into artefact-free and filtered intervals, randomly reordered for dissociation, and independently offered to four reviewers for rhythm annotation. The rhythm annotations of the artefact-free intervals were considered as the gold standard against which the rhythm annotations of the filtered intervals were evaluated. For the filtered intervals, the rater agreement (κ, Kappa score) with the gold standard, the sensitivity and the specificity were computed individually for each reviewer, and jointly through the majority decision of the pool of reviewers (DPR). These results were also compared to those obtained using a commercial shock advisory algorithm (SAA).
RESULTS: The agreement between each reviewer and the gold standard was moderate ranging between κ = 0.41-0.64. The sensitivities and specificities ranged between 64.3-95.0%, and 70.0-95.9%, respectively. The agreement for the DPR was substantial with κ = 0.64 (0.62-0.66), a sensitivity of 90.6%, and a specificity of 85.6%. For the SAA, the agreement was fair with κ = 0.33 (0.31-0.35), a sensitivity of 90.3%, and a specificity of 66.4%.
CONCLUSION: Clinicians outperformed the SAA, but specificities remained below the specifications recommended by the American Heart Association. Visual assessment of the filtered ECG by clinicians is not reliable enough, and varies greatly among clinicians. Results considerably improve by considering the consensus decision of a pool of clinicians.
参考来源
- Alonso E, Aramendi E, Irusta U, et al. Evaluation of chest compression artefact removal based on rhythm assessments made by clinicians. Resuscitation. 2018. PMID: 29412147. doi:10.1016/j.resuscitation.2018.01.056
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。