文献速递复苏、休克与脓毒症

使用定制复苏板的标准化猪复苏模型可实现最佳血流动力学管理

Standardized model of porcine resuscitation using a custom-made resuscitation board results in optimal hemodynamic management.
PubMed 文献 · Am J Emerg Med · 2018-01-31
一句话结论在10头德国杂交长白猪窒息性心脏骤停模型中,定制复苏板配合LUCAS® II机械胸外按压可稳定实现CPR期间的平均动脉压46±1 mmHg和平均肺动脉压36±1 mmHg。

该研究设计了一种「猪适配」复苏板,用于配合LUCAS® II气动胸外按压装置,在10头德国杂交长白猪中诱导窒息性心脏骤停,并按ERC/AHA 2015指南实施机械胸外按压CPR。CPR期间平均动脉压(MAP)为46±1 mmHg,平均肺动脉压(mPAP)为36±1 mmHg,每搏输出量106±3 ml、收缩力1097±22 mmHg/s。自主循环恢复后2小时MAP恢复至基线值80±4 mmHg,仅需中等剂量血管升压药。血气分析显示CPR典型改变并随病程正常化,热稀释参数未显示持续性血管内液体转移。作者结论为标准化CPR在猪模型中可行,能获得一致质量的血流动力学和组织灌注。

要点

  • 10头德国杂交长白猪窒息性心脏骤停后,使用定制「猪适配」复苏板配合LUCAS® II机械胸外按压,CPR期间MAP达46±1 mmHg、mPAP达36±1 mmHg。
  • CPR期间每搏输出量106±3 ml、收缩力1097±22 mmHg/s,通过脉搏轮廓分析获得。
  • 自主循环恢复后2小时MAP恢复至80±4 mmHg,仅需中等剂量血管升压药。
  • 血气分析显示CPR典型改变并随病程正常化,热稀释参数未显示持续性血管内液体转移。
  • 作者结论为标准化CPR在猪模型中可行,能获得一致质量的血流动力学和连续组织灌注。

适用人群与场景

  • 10头德国杂交长白猪,窒息性心脏骤停模型,用于评估机械胸外按压CPR的血流动力学。

处置流程与药物剂量

  • 按ERC/AHA 2015指南实施机械胸外按压CPR,使用定制「猪适配」复苏板配合LUCAS® II气动胸外按压装置(Physio-Control Inc.)。
  • 自主循环恢复后使用中等剂量血管升压药维持MAP,2小时MAP恢复至80±4 mmHg。

研究设计与关键结果

  • 研究类型为猪实验模型(窒息性心脏骤停,10头德国杂交长白猪),干预为定制复苏板+LUCAS® II机械胸外按压,按ERC/AHA 2015指南实施CPR。
  • CPR期间MAP 46±1 mmHg、mPAP 36±1 mmHg;每搏输出量106±3 ml、收缩力1097±22 mmHg/s。
  • 自主循环恢复后2小时MAP恢复至基线80±4 mmHg,需中等剂量血管升压药。
  • 血气分析显示CPR典型改变并随病程正常化;热稀释参数未显示持续性血管内液体转移。

证据类型、等级与局限

  • 证据类型:动物实验(猪模型),未报告证据等级。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为标准化CPR在猪模型中可行,能获得一致质量的血流动力学和连续组织灌注。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: Standardized modeling of cardiac arrest and cardiopulmonary resuscitation (CPR) is crucial to evaluate new treatment options. Experimental porcine models are ideal, closely mimicking human-like physiology. However, anteroposterior chest diameter differs significantly, being larger in pigs and thus poses a challenge to achieve adequate perfusion pressures and consequently hemodynamics during CPR, which are commonly achieved during human resuscitation. The aim was to prove that standardized resuscitation is feasible and renders adequate hemodynamics and perfusion in pigs, using a specifically designed resuscitation board for a pneumatic chest compression device.

METHODS AND RESULTS: A "porcine-fit" resuscitation board was designed for our experiments to optimally use a pneumatic compression device (LUCAS® II, Physio-Control Inc.), which is widely employed in emergency medicine and ideal in an experimental setting due to its high standardization. Asphyxial cardiac arrest was induced in 10 German hybrid landrace pigs and cardiopulmonary resuscitation was performed according to ERC/AHA 2015 guidelines with mechanical chest compressions. Hemodynamics were measured in the carotid and pulmonary artery. Furthermore, arterial blood gas was drawn to assess oxygenation and tissue perfusion. The custom-designed resuscitation board in combination with the LUCAS® device demonstrated highly sufficient performance regarding hemodynamics during CPR (mean arterial blood pressure, MAP 46 ± 1 mmHg and mean pulmonary artery pressure, mPAP of 36 ± 1 mmHg over the course of CPR). MAP returned to baseline values at 2 h after ROSC (80 ± 4 mmHg), requiring moderate doses of vasopressors. Furthermore, stroke volume and contractility were analyzed using pulse contour analysis (106 ± 3 ml and 1097 ± 22 mmHg/s during CPR). Blood gas analysis revealed CPR-typical changes, normalizing in the due course. Thermodilution parameters did not show persistent intravascular volume shift.

CONCLUSION: Standardized cardiopulmonary resuscitation is feasible in a porcine model, achieving adequate hemodynamics and consecutive tissue perfusion of consistent quality.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Wollborn J, Ruetten E, Schlueter B, et al. Standardized model of porcine resuscitation using a custom-made resuscitation board results in optimal hemodynamic management. Am J Emerg Med. 2018. PMID: 29395757. doi:10.1016/j.ajem.2018.01.059

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。