文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

应用新型自动呼吸机不同步检测算法分析呼吸机不同步、输送潮气量与镇静的关联

The Association Between Ventilator Dyssynchrony, Delivered Tidal Volume, and Sedation Using a Novel Automated Ventilator Dyssynchrony Detection Algorithm.
PubMed 文献 · Crit Care Med · 2018-01-01
一句话结论双触发和限流型不同步更常输送大于10 mL/kg的潮气量;深镇静减少但不能消除不同步,神经肌肉阻滞可消除不同步。

这项前瞻性观察研究在大学医疗ICU纳入62例有或存在急性呼吸窘迫综合征风险的患者,从呼吸机连续采集426万次呼吸的压力-时间、流量-时间和容量-时间数据,用结合临床洞察的机器学习算法检测四种不同步。算法检测三种不同步的受试者工作特征曲线下面积大于0.89;不同步占全部呼吸的34.4%(95%CI 34.41-34.49%)。与同步呼吸相比,双触发和限流型呼吸更常输送大于10 mL/kg的潮气量(分别为40%和11%比0.2%,两项比较p<0.001)。深镇静减少但不能消除所有不同步呼吸的频率(p<0.05),神经肌肉阻滞可消除不同步(p<0.001)。

要点

  • 不同步呼吸占全部呼吸的34.4%(95%CI 34.41-34.49%),算法检测三种不同步的受试者工作特征曲线下面积大于0.89。
  • 双触发呼吸中40%输送潮气量大于10 mL/kg,限流型呼吸中11%输送潮气量大于10 mL/kg,同步呼吸仅0.2%(两项比较p<0.001)。
  • 深镇静减少但不能消除所有不同步呼吸的频率(p<0.05),仍可能输送潜在有害潮气量。
  • 神经肌肉阻滞可消除呼吸机不同步(p<0.001)。
  • 研究为前瞻性观察设计,在 university medical ICU 纳入62例有或存在ARDS风险的患者,记录426万次呼吸。

适用人群与场景

  • 有或存在急性呼吸窘迫综合征风险的机械通气患者,来自大学医疗ICU。

研究设计与关键结果

  • 前瞻性观察研究,纳入62例机械通气患者,记录426万次呼吸,用机器学习算法检测四种不同步。
  • 算法检测三种不同步的受试者工作特征曲线下面积大于0.89;不同步占全部呼吸的34.4%(95%CI 34.41-34.49%)。
  • 双触发和限流型呼吸较同步呼吸更常输送大于10 mL/kg的潮气量:双触发40% vs 同步0.2%,限流型11% vs 同步0.2%(两项比较p<0.001)。
  • 深镇静减少但不能消除所有不同步呼吸的频率(p<0.05);神经肌肉阻滞可消除不同步(p<0.001)。

证据类型、等级与局限

  • 证据类型:前瞻性观察研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 对于有或存在ARDS风险的机械通气患者,双触发和限流型不同步常伴随大于10 mL/kg的潮气量输送,床旁应关注这两种不同步。
  • 深镇静可减少不同步频率但可能仍输送潜在有害潮气量;神经肌肉阻滞可消除不同步。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: Ventilator dyssynchrony is potentially harmful to patients with or at risk for the acute respiratory distress syndrome. Automated detection of ventilator dyssynchrony from ventilator waveforms has been difficult. It is unclear if certain types of ventilator dyssynchrony deliver large tidal volumes and whether levels of sedation alter the frequency of ventilator dyssynchrony.

DESIGN: A prospective observational study.

SETTING: A university medical ICU.

PATIENTS: Patients with or at risk for acute respiratory distress syndrome.

INTERVENTIONS: Continuous pressure-time, flow-time, and volume-time data were directly obtained from the ventilator. The level of sedation and the use of neuromuscular blockade was extracted from the medical record. Machine learning algorithms that incorporate clinical insight were developed and trained to detect four previously described and clinically relevant forms of ventilator dyssynchrony. The association between normalized tidal volume and ventilator dyssynchrony and the association between sedation and the frequency of ventilator dyssynchrony were determined.

MEASUREMENTS AND MAIN RESULTS: A total of 4.26 million breaths were recorded from 62 ventilated patients. Our algorithm detected three types of ventilator dyssynchrony with an area under the receiver operator curve of greater than 0.89. Ventilator dyssynchrony occurred in 34.4% (95% CI, 34.41-34.49%) of breaths. When compared with synchronous breaths, double-triggered and flow-limited breaths were more likely to deliver tidal volumes greater than 10 mL/kg (40% and 11% compared with 0.2%; p < 0.001 for both comparisons). Deep sedation reduced but did not eliminate the frequency of all ventilator dyssynchrony breaths (p < 0.05). Ventilator dyssynchrony was eliminated with neuromuscular blockade (p < 0.001).

CONCLUSION: We developed a computerized algorithm that accurately detects three types of ventilator dyssynchrony. Double-triggered and flow-limited breaths are associated with the frequent delivery of tidal volumes of greater than 10 mL/kg. Although ventilator dyssynchrony is reduced by deep sedation, potentially deleterious tidal volumes may still be delivered. However, neuromuscular blockade effectively eliminates ventilator dyssynchrony.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Sottile PD, Albers D, Higgins C, et al. The Association Between Ventilator Dyssynchrony, Delivered Tidal Volume, and Sedation Using a Novel Automated Ventilator Dyssynchrony Detection Algorithm. Crit Care Med. 2018. PMID: 29337804. doi:10.1097/CCM.0000000000002849

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。