床旁腕部超声在尺侧疼痛与不稳创伤患者中的应用
该前瞻性横断面研究在急诊科纳入65例尺侧腕扭伤和不稳患者,由一名急诊医生和一名肌骨放射 fellow 独立行床旁腕部超声,评估三角纤维软骨(TFC)、半月板同系物、掌侧和背侧远端桡尺韧带及尺侧腕伸肌,分为正常、部分撕裂或完全撕裂,以3T-MRI为参考标准。床旁超声诊断敏感度97.2-99.1%、特异度96.8-97.3%、准确度96.9-97.9%,两位评估者间诊断效能无显著差异(p=0.58-0.98)。各评估者与参考标准的一致性极佳(急诊医生ICC=0.964;肌骨放射 fellow ICC=0.976),观察者间一致性亦极佳(ICC=0.968)。作者认为床旁腕部超声检测TFCC损伤与MRI同样精确,可用于即刻诊断和进一步的术前影像,并可能缩短从急诊入院到手术干预的间隔,同时降低成本。
要点
- 在急诊科尺侧腕扭伤和不稳患者中,床旁腕部超声诊断TFCC损伤的敏感度97.2-99.1%、特异度96.8-97.3%、准确度96.9-97.9%。
- 急诊医生与肌骨放射 fellow 的床旁超声诊断效能无显著差异(p=0.58-0.98)。
- 急诊医生与参考标准的一致性ICC=0.964,肌骨放射 fellow 与参考标准的一致性ICC=0.976,观察者间一致性ICC=0.968。
- 作者认为床旁腕部超声检测TFCC损伤与MRI同样精确,可用于即刻诊断和进一步的术前影像。
- 作者认为床旁腕部超声可能缩短从急诊入院到手术干预的间隔,同时降低成本。
适用人群与场景
- 急诊科中尺侧腕扭伤和不稳的创伤患者。
研究设计与关键结果
- 研究类型为前瞻性横断面研究,在急诊科纳入65例尺侧腕扭伤和不稳患者。
- 由一名急诊医生和一名肌骨放射 fellow 独立行床旁腕部超声,评估TFC、半月板同系物、掌侧和背侧远端桡尺韧带及尺侧腕伸肌,结果分为正常、部分撕裂或完全撕裂,以3T-MRI为参考标准。
- 床旁腕部超声诊断TFCC损伤的敏感度97.2-99.1%、特异度96.8-97.3%、准确度96.9-97.9%。
- 两位评估者间的诊断效能无显著差异(p=0.58-0.98)。
- 急诊医生与参考标准的一致性ICC=0.964,肌骨放射 fellow 与参考标准的一致性ICC=0.976,观察者间一致性ICC=0.968。
证据类型、等级与局限
- 证据类型:前瞻性横断面研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为床旁腕部超声检测TFCC损伤与MRI同样精确,可用于即刻诊断和进一步的术前影像。
- 作者认为床旁腕部超声可能缩短从急诊入院到手术干预的间隔,同时降低成本。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: We evaluated the effectiveness of point-of-care wrist ultrasonography compared with 3T-magnetic resonance imaging (MRI) for diagnosing triangular fibrocartilage complex (TFCC) injuries in trauma patients with ulnar-sided pain and instability. Moreover, we assessed the inter-observer variability between an emergency physician and a musculoskeletal radiology fellow.
MATERIAL AND METHODS: A prospective cross-sectional study was conducted in an emergency department; patients with ulnar-sided sprain and instability were recruited. An emergency physician and a musculoskeletal radiology fellow independently evaluated the TFC, meniscal homologue, volar and dorsal distal radioulnar ligaments, and extensor carpi ulnaris using point-of-care ultrasonography. Findings were classified as normal, partial rupture, or complete rupture. Wrist 3T-MRI was used as the reference standard. We compared the diagnostic values for point-of-care ultrasonography obtained by both reviewers using DeLong's test. Intra-class correlation coefficients (ICCs) were calculated for agreement between each reviewer and the reference standard, and directly between the two reviewers.
RESULTS: Sixty-five patients were enrolled. Point-of-care wrist ultrasonography showed acceptable sensitivity (97.2-99.1%), specificity (96.8-97.3%), and accuracy (96.9-97.9%); these diagnostic performance values did not differ significantly between reviewers (p=0.58-0.98). Agreement between each reviewer and the reference standard was excellent (emergency physician, ICC=0.964; musculoskeletal radiology fellow, ICC=0.976), as was the inter-observer agreement (ICC=0.968).
CONCLUSION: Point-of-care wrist ultrasonography is as precise as MRI for detecting TFCC injuries, and can be used for immediate diagnosis and further preoperative imaging. Moreover, it may shorten the interval from emergency department admission to surgical intervention while reducing costs.
参考来源
- Lee SH, Yun SJ. Point-of-care wrist ultrasonography in trauma patients with ulnar-sided pain and instability. Am J Emerg Med. 2018. PMID: 29307765. doi:10.1016/j.ajem.2018.01.005
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。