低于ARDS协作网方案的呼气末正压与儿童急性呼吸窘迫综合征死亡率升高相关
该多中心回顾性研究合并4个数据集,纳入1134例未按正式PEEP/FiO2方案管理的儿童急性呼吸窘迫综合征(PARDS)患者,计算诊断后24小时内实际PEEP与ARDS协作网(ARDSNet)PEEP/FiO2模型推荐值的差值。26.6%的患者使用了低于推荐值的PEEP,其死亡率高于PEEP达标或高于推荐值者(P < 0.001)。校正低氧血症、正性肌力药、合并症、病情严重度、呼吸机设置、一氧化氮及数据集后,低PEEP仍独立与死亡率升高相关(OR 2.05,95%CI 1.32-3.17),倾向性评分校正后结果相似(OR 2.00,95%CI 1.24-3.22)。作者认为需要针对PARDS的PEEP管理开展临床试验。
要点
- 在1134例PARDS患者中,26.6%按FiO2对应的ARDSNet PEEP/FiO2模型使用了更低的PEEP,其ICU死亡率高于PEEP达标或更高者(P < 0.001)。
- 校正低氧血症、正性肌力药、合并症、病情严重度、呼吸机设置、一氧化氮及数据集后,低PEEP仍独立与更高死亡率相关(OR 2.05,95%CI 1.32-3.17)。
- 倾向性评分校正后低PEEP与死亡率的关联相似(OR 2.00,95%CI 1.24-3.22)。
- 该研究为多中心回顾性分析,4个数据集合并,患者均未按正式PEEP/FiO2方案管理。
适用人群与场景
- 儿童急性呼吸窘迫综合征(PARDS)患者,未按正式PEEP/FiO2方案管理,来自4个数据集合并的多中心回顾性分析。
研究设计与关键结果
- 研究类型:多中心回顾性分析,合并4个数据集,纳入1134例PARDS患者。
- 暴露:诊断PARDS后24小时内实际PEEP与ARDSNet PEEP/FiO2模型推荐PEEP的差值中位数;26.6%的患者使用低于推荐值的PEEP。
- 主要结果:低PEEP组ICU死亡率高于PEEP达标或高于推荐值组(P < 0.001)。
- 校正后:校正低氧血症、正性肌力药、合并症、病情严重度、呼吸机设置、一氧化氮及数据集后,低PEEP与更高死亡率独立相关(OR 2.05,95%CI 1.32-3.17)。
- 倾向性评分校正后:低PEEP与更高死亡率相关(OR 2.00,95%CI 1.24-3.22)。
证据类型、等级与局限
- 证据类型:多中心回顾性分析(4个数据集合并)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,需要开展针对PARDS的PEEP管理临床试验。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
RATIONALE: The ARDS Network (ARDSNet) used a positive end-expiratory pressure (PEEP)/FiO2 model in many studies. In general, pediatric intensivists use less PEEP and higher FiO2 than this model.
OBJECTIVES: To evaluate whether children managed with PEEP lower than recommended by the ARDSNet PEEP/FiO2 model had higher mortality.
METHODS: This was a multicenter, retrospective analysis of patients with pediatric acute respiratory distress syndrome (PARDS) managed without a formal PEEP/FiO2 protocol. Four distinct datasets were combined for analysis. We extracted time-matched PEEP/FiO2 values, calculating the difference between PEEP level and the ARDSNet-recommended PEEP level for a given FiO2. We analyzed the median difference over the first 24 hours of PARDS diagnosis against ICU mortality and adjusted for confounding variables, effect modifiers, or factors that may have affected the propensity to use lower PEEP.
MEASUREMENTS AND MAIN RESULTS: Of the 1,134 patients with PARDS, 26.6% were managed with lower PEEP relative to the amount of FiO2 recommended by the ARDSNet protocol. Patients managed with lower PEEP experienced higher mortality than those who were managed with PEEP levels in line with or higher than recommended by the protocol (P < 0.001). After adjustment for hypoxemia, inotropes, comorbidities, severity of illness, ventilator settings, nitric oxide, and dataset, PEEP lower than recommended by the protocol remained independently associated with higher mortality (odds ratio, 2.05; 95% confidence interval, 1.32-3.17). Findings were similar after propensity-based covariate adjustment (odds ratio, 2.00; 95% confidence interval, 1.24-3.22).
CONCLUSIONS: Patients with PARDS managed with lower PEEP relative to FiO2 than recommended by the ARDSNet model had higher mortality. Clinical trials targeting PEEP management in PARDS are needed.
参考来源
- Khemani RG, Parvathaneni K, Yehya N, et al. Positive End-Expiratory Pressure Lower Than the ARDS Network Protocol Is Associated with Higher Pediatric Acute Respiratory Distress Syndrome Mortality. Am J Respir Crit Care Med. 2018. PMID: 29373802. doi:10.1164/rccm.201707-1404OC
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。