重新分类急性呼吸窘迫综合征
研究在中度ARDS(P/F 100-200 mm Hg)内以150 mm Hg为界分为轻中度(n=50)和中重度(n=55),后者峰压、PaCO2、pH更高,肺更重、不均质性更大、未充气组织更多、肺复张性更大。严重ARDS(P/F<100 mm Hg,84例)以FiO2 80%为界分为高FiO2组(n=63)和低FiO2组(n=18),75%属于高FiO2组,两组仅PaCO2和肺重量不同。46例接受ECMO者中41例属于高FiO2组,该组内ECMO患者PaCO2、不均质性比值、总肺重量和未充气组织显著更高。结论认为150 mm Hg阈值使ARDS严重度亚组分布更均质,并识别出解剖和生理特征不同的两类人群。
要点
- 中度ARDS以P/F 150 mm Hg为界分为轻中度(n=50)和中重度(n=55),中重度组峰压、PaCO2、pH更高。
- 中重度ARDS组肺更重、不均质性更大、未充气组织更多、肺复张性更大。
- 严重ARDS(P/F<100 mm Hg)84例中75%属于FiO2≥80%的高FiO2亚组(n=63),低FiO2亚组n=18。
- 46例接受ECMO者中41例(近90%)属于高FiO2亚组;该组内ECMO患者PaCO2、不均质性比值、总肺重量和未充气组织显著更高。
- 高FiO2与低FiO2的严重ARDS亚组仅PaCO2和肺重量不同。
适用人群与场景
- 中度ARDS患者(P/F 100-200 mm Hg),分为轻中度(n=50)和中重度(n=55)。
- 严重ARDS患者(P/F<100 mm Hg),分为高FiO2组(n=63)和低FiO2组(n=18);3例FiO2数据缺失。
诊断标准与关键阈值
- 以P/F 150 mm Hg为阈值将中度ARDS(P/F 100-200 mm Hg)分为轻中度与中重度。
- 以FiO2 80%为阈值将严重ARDS(P/F<100 mm Hg)分为高FiO2组与低FiO2组。
研究设计与关键结果
- 研究类型为单中心研究(原文未明确写单中心,但为同一研究队列),中度ARDS按P/F 150 mm Hg分为轻中度(n=50)和中重度(n=55)。
- 与轻中度ARDS相比,中重度ARDS患者峰压、PaCO2、pH更高,肺更重、不均质性更大、未充气组织更多、肺复张性更大。
- 严重ARDS(P/F<100 mm Hg)84例中75%属于高FiO2亚组(n=63),高FiO2组与低FiO2组(n=18)仅在PaCO2和肺重量上不同。
- 46例接受ECMO的患者中41例属于高FiO2组;高FiO2组内ECMO患者PaCO2、不均质性比值、总肺重量和未充气组织显著高于22例非ECMO患者。
证据类型、等级与局限
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,使用150 mm Hg的P/F阈值可使ARDS严重度亚组分布更均质,并识别出解剖和生理特征不同的两类人群。
- 作者指出,接受ECMO治疗的严重ARDS患者几乎90%属于高FiO2亚组。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
RATIONALE: The ratio of PaO2 to FiO2 (P/F) defines acute respiratory distress syndrome (ARDS) severity and suggests appropriate therapies.
OBJECTIVES: We investigated 1) whether a 150-mm-Hg P/F threshold within the range of moderate ARDS (100-200 mm Hg) would define two subgroups that were more homogeneous; and 2) which criteria led the clinicians to apply extracorporeal membrane oxygenation (ECMO) in severe ARDS.
METHODS: At the 150-mm-Hg P/F threshold, moderate patients were split into mild-moderate (n = 50) and moderate-severe (n = 55) groups. Patients with severe ARDS (FiO2 not available in three patients) were split into higher (n = 63) and lower (n = 18) FiO2 groups at an 80% FiO2 threshold.
MEASUREMENTS AND MAIN RESULTS: Compared with mild-moderate ARDS, patients with moderate-severe ARDS had higher peak pressures, PaCO2, and pH. They also had heavier lungs, greater inhomogeneity, more noninflated tissue, and greater lung recruitability. Within 84 patients with severe ARDS (P/F < 100 mm Hg), 75% belonged to the higher FiO2 subgroup. They differed from the patients with severe ARDS with lower FiO2 only in PaCO2 and lung weight. Forty-one of 46 patients treated with ECMO belonged to the higher FiO2 group. Within this group, the patients receiving ECMO had higher PaCO2 than the 22 non-ECMO patients. The inhomogeneity ratio, total lung weight, and noninflated tissue were also significantly higher.
CONCLUSIONS: Using the 150-mm-Hg P/F threshold gave a more homogeneous distribution of patients with ARDS across the severity subgroups and identified two populations that differed in their anatomical and physiological characteristics. The patients treated with ECMO belonged to the severe ARDS group, and almost 90% of them belonged to the higher FiO2 subgroup.
参考来源
- Maiolo G, Collino F, Vasques F, et al. Reclassifying Acute Respiratory Distress Syndrome. Am J Respir Crit Care Med. 2018. PMID: 29345967. doi:10.1164/rccm.201709-1804OC
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。