施救者能否准确执行未来指南可能推荐的胸外按压深度细微变化

Can rescuers accurately deliver subtle changes to chest compression depth if recommended by future guidelines?
指南 / 共识 · Resuscitation · 2018-01-05
一句话结论BLS培训的医护人员能区分0.5 cm的按压深度差异,但无法准确达到目标深度;将推荐深度降至4.56 cm可能导致实际按压深度显著低于最佳深度。

这项随机干预试验纳入101名BLS培训的医护人员(1名退出),在成人模拟人上无反馈装置下按压2分钟,随机目标深度为4.0-5.0 cm、4.5-5.5 cm或5.0-6.0 cm,频率100-120次/分。三组中位深度分别为3.66 cm、4.13 cm和4.76 cm(P<0.001),仅18人成功达到目标深度。作者结论:施救者能精确判断0.5 cm的深度差异,但仍无法准确判断总体目标深度;将当前推荐深度降至4.56 cm可能导致实际按压深度显著低于最佳深度。

要点

  • BLS培训医护人员在无反馈装置下按压2分钟,三组目标深度4.0-5.0 cm、4.5-5.5 cm、5.0-6.0 cm的实际中位深度分别为3.66 cm、4.13 cm、4.76 cm(P<0.001)。
  • 101名参与者中仅18人成功按压至目标深度,提示无反馈时总体目标深度准确性差。
  • 施救者能分辨0.5 cm的深度差异(三组中位深度随目标升高而递增),但整体按压偏浅。
  • 作者认为将推荐深度降至4.56 cm很可能导致实际按压深度显著低于最佳深度。

适用人群与场景

  • BLS培训的医护人员,在成人模拟人上完成2分钟连续胸外按压,无反馈装置。

研究设计与关键结果

  • 随机干预试验,纳入101名BLS培训医护人员(1名退出),随机目标深度4.0-5.0 cm(n=30)、4.5-5.5 cm(n=35)、5.0-6.0 cm(n=35),按压频率100-120次/分,无反馈装置。
  • 三组实际中位深度分别为3.66 cm(IQR 3.37-4.16 cm)、4.13 cm(IQR 3.65-4.36 cm)、4.76 cm(IQR 4.16-5.24 cm),P<0.001。
  • 仅18名参与者成功按压至目标深度。

证据类型、等级与局限

  • 证据类型:随机干预试验。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论:施救者能精确判断0.5 cm的按压深度差异,但仍无法准确判断总体目标深度;将当前推荐深度降至4.56 cm很可能导致实际按压深度显著低于最佳深度。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: A recent study reported that a compression depth of 4.56 cm optimised survival following cardiac arrest, which is at variance with the current guidelines of 5.0-6.0 cm. A reduction in recommended compression depth is only likely to improve survival if healthcare professionals can accurately deliver a relatively small change in target depth. This study aimed to determine if healthcare professionals could accurately judge their delivered compression depth by 0.5 cm increments.

METHOD: This randomised interventional trial asked BLS-trained healthcare professionals to complete two minutes of continuous chest compressions on an adult manikin, randomised (without any feedback device), to compress to one of three target depth ranges of 4.0-5.0 cm, 4.5-5.5 cm or 5.0-6.0 cm, at the recommended rate of 100-120 compressions min-1. Basic demographic data, compression rate, and compression depth were recorded.

RESULTS: One hundred and one participants were recruited, of whom one withdrew. Median depths of 3.66 cm (IQR: 3.37-4.16 cm), 4.13 cm (IQR: 3.65-4.36 cm) and 4.76 cm (IQR: 4.16-5.24 cm) were found for the target depths of 4.0-5.0 cm (n = 30), 4.5-5.5 cm (n = 35) and 5.0-6.0 cm (n = 35) respectively (P < 0.001). Overall, 18 participants successfully compressed to their target depth.

CONCLUSIONS: Rescuers are able to judge 0.5 cm differences in compression depth with precision, but remain unable to accurately judge overall target depth. Reducing the current recommended compression depth to 4.56 cm is likely to result in delivered compressions significantly below the optimal depth.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Deakin CD, Sidebottom DB, Potter R, et al. Can rescuers accurately deliver subtle changes to chest compression depth if recommended by future guidelines? Resuscitation. 2018. PMID: 29309883. doi:10.1016/j.resuscitation.2018.01.010

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。