文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

近红外光谱预测脓毒症器官衰竭与结局:ARISTOS研究

Near-infrared spectroscopy to predict organ failure and outcome in sepsis: the Assessing Risk in Sepsis using a Tissue Oxygen Saturation (ARISTOS) study.
PubMed 文献 · Eur J Emerg Med · 2019-01-01
一句话结论在急诊感染患者中,近红外光谱测得的组织氧饱和度与器官衰竭相关,但区分脓毒症的能力有限,不能推荐用于该目的。

ARISTOS为多中心前瞻性观察队列研究,在3家澳大利亚医院急诊科纳入323例因感染住院的患者,用手持近红外光谱设备Inspectra 300测量组织氧饱和度(StO2)。143例(44%)符合脓毒症标准,22例(7%)30天内死亡。脓毒症组平均StO2为74±8%,非脓毒症组为78±7%(P<0.0001);StO2与峰值SOFA评分相关(Spearman ρ -0.27,P<0.0001)。StO2预测脓毒症的AUC为0.66(95%CI 0.60-0.72),预测复合结局(院内死亡/ICU入住≥3天)的AUC为0.66(95%CI 0.58-0.75);StO2<75%者复合结局的OR为2.67(95%CI 1.45-4.94;P=0.002)。作者结论:StO2与器官衰竭相关并与结局相关,但区分急诊感染患者中的脓毒症能力有限,不能推荐用于该目的。

要点

  • 在急诊感染患者中,StO2<75%者复合结局(院内死亡/ICU入住≥3天)的OR为2.67(95%CI 1.45-4.94;P=0.002),提示与不良结局相关。
  • StO2预测脓毒症的AUC为0.66(95%CI 0.60-0.72),预测复合结局的AUC为0.66(95%CI 0.58-0.75),区分能力有限。
  • 脓毒症组平均StO2为74±8%,非脓毒症组为78±7%(P<0.0001);StO2与峰值SOFA评分相关(Spearman ρ -0.27,P<0.0001)。
  • 作者结论明确:近红外光谱测得的StO2不能推荐用于急诊感染患者识别脓毒症。

适用人群与场景

  • 因感染被收入院的急诊科患者,来自3家澳大利亚医院,中位年龄64岁(四分位距47-77岁)。

诊断标准与关键阈值

  • 脓毒症定义为72小时内序贯器官衰竭评估(SOFA)评分增加至少2分。
  • 复合结局定义为院内死亡和(或)入住ICU至少3天。

研究设计与关键结果

  • 多中心前瞻性观察队列研究,纳入323例因感染住院的急诊患者,143例(44%)符合脓毒症标准,22例(7%)30天内死亡。
  • 脓毒症组平均StO2为74±8%,非脓毒症组为78±7%(P<0.0001);StO2与峰值SOFA评分相关(Spearman ρ -0.27,P<0.0001)。
  • StO2预测脓毒症的AUC为0.66(95%CI 0.60-0.72),预测复合结局的AUC为0.66(95%CI 0.58-0.75)。
  • StO2<75%者复合结局的OR为2.67(95%CI 1.45-4.94;P=0.002),对照为StO2≥75%。

证据类型、等级与局限

  • 证据类型:多中心前瞻性观察队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论:近红外光谱测得的StO2与器官衰竭相关并与结局相关,但其区分急诊感染患者中脓毒症的能力有限,不能推荐用于该目的。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: Sepsis is acute organ dysfunction in the setting of infection. An accurate diagnosis is important to guide treatment and disposition. Tissue oxygen saturation (StO2) can be estimated noninvasively by near-infrared spectroscopy (NIRS), and may be an indicator of microcirculatory dysfunction in early sepsis. We aimed to determine the utility of StO2 for sepsis recognition and outcome prediction among patients presenting to the emergency department (ED) with infection.

PATIENTS AND METHODS: A multicentre, prospective, observational cohort study recruited patients who were being admitted to hospital with infection. StO2 was measured in the ED using a handheld NIRS device, Inspectra 300. Outcomes were sepsis, defined as an increase in sequential organ failure assessment score of at least 2 points within 72 h, and composite in-hospital mortality/ICU admission at least 3 days.

RESULTS: A cohort of 323 participants, median age 64 (interquartile range: 47-77) years, was recruited at three Australian hospitals. 143 (44%) fulfilled the criteria for sepsis and 22 (7%) died within 30 days. The mean ± SD StO2 was 74 ± 8% in sepsis and 78 ± 7% in nonsepsis (P < 0.0001). StO2 correlated with the peak sequential organ failure assessment score (Spearman's ρ -0.27, P < 0.0001). Area under the receiver operating characteristic curve was 0.66 (95% confidence interval: 0.60-0.72) for sepsis and 0.66 (0.58-0.75) for the composite outcome. StO2 less than 75% had an odds ratio of 2.67 (1.45-4.94; P = 0.002), for the composite outcome compared with StO2 at least 75%.

CONCLUSION: NIRS-derived StO2 correlates with organ failure and is associated with outcome in sepsis. However, its ability to differentiate sepsis among ED patients with infection is limited. NIRS cannot be recommended for this purpose.

来源:Eur J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Macdonald SPJ, Kinnear FB, Arendts G, et al. Near-infrared spectroscopy to predict organ failure and outcome in sepsis: the Assessing Risk in Sepsis using a Tissue Oxygen Saturation (ARISTOS) study. Eur J Emerg Med. 2019. PMID: 29346183. doi:10.1097/MEJ.0000000000000535

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。