文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

呼气末下腔静脉直径预测容量反应性的价值有限:腹腔内压的影响

Limited value of end-expiratory inferior vena cava diameter to predict fluid responsiveness impact of intra-abdominal pressure.
PubMed 文献 · Intensive Care Med · 2018-01-22
一句话结论机械通气休克患者中呼气末下腔静脉直径预测容量反应性能力差,腹腔内压是混杂因素,不应单独用于液体预测。

这项多中心研究纳入540例连续机械通气休克患者,由专家行超声评估呼气末下腔静脉直径(IVCEE)、左室流出道速度时间积分(VTI)和腹腔内压(IAP),以被动抬腿试验后1分钟左室流出道VTI升高≥10%定义容量反应性。117例(22%)未获得IVCEE,最终分析423例,其中脓毒症休克56%,IAP≥12 mmHg者129例(30%),容量反应性者172例(41%)。IVCEE≤13 mm仅在62例(15%)中以至少80%特异度预测容量反应性,IVCEE≥25 mm仅在61例(14%)中以至少80%特异度预测无容量反应性,其余300例(71%)的中间值无法预测。调整后IVCEE与容量反应性存在关系,但在IAP≥12 mmHg患者中该关系较弱;作者认为IVCEE可行性中等、预测能力差,不应单独用于液体预测。

要点

  • 423例可评估患者中仅172例(41%)有容量反应性,IVCEE≤13 mm仅在62例(15%)中以至少80%特异度预测容量反应性。
  • IVCEE≥25 mm仅在61例(14%)中以至少80%特异度预测无容量反应性,其余300例(71%)中间值无法预测。
  • 129例(30%)IAP≥12 mmHg,调整后IVCEE与容量反应性的关系在IAP≥12 mmHg患者中较弱,IAP是混杂因素。
  • 117例(22%)未能获得IVCEE,作者认为在机械通气患者中测量IVCEE可行性中等。
  • 作者结论:IVCEE可能对指导液体治疗有一定附加价值,但不应单独用于液体预测。

适用人群与场景

  • 多中心连续纳入的540例机械通气休克患者,休克病因多样,其中脓毒症休克占56%。
  • 最终分析423例获得IVCEE测量者,其中129例(30%)IAP≥12 mmHg,172例(41%)有容量反应性。

诊断标准与关键阈值

  • 容量反应性定义:被动抬腿试验1分钟后左室流出道速度时间积分(LVOT VTI)升高≥10%。
  • 腹腔内压升高定义:IAP≥12 mmHg。
  • IVCEE预测容量反应性的界值:IVCEE≤13 mm预测有容量反应性,特异度至少80%(62例,15%)。
  • IVCEE预测无容量反应性的界值:IVCEE≥25 mm预测无容量反应性,特异度至少80%(61例,14%)。

处置流程与药物剂量

  • 对机械通气休克患者行超声评估,测量呼气末下腔静脉直径(IVCEE)、左室流出道速度时间积分(VTI)和腹腔内压(IAP)。
  • 系统使用被动抬腿试验进行可逆的中心血容量扩张,1分钟后测LVOT VTI判断容量反应性。

研究设计与关键结果

  • 多中心研究,540例连续机械通气休克患者接受专家超声评估,117例(22%)未获得IVCEE,最终分析423例,脓毒症休克56%,IAP≥12 mmHg者129例(30%),容量反应性者172例(41%)。
  • IVCEE≤13 mm在62例(15%)中以至少80%特异度预测容量反应性,IVCEE≥25 mm在61例(14%)中以至少80%特异度预测无容量反应性,其余300例(71%)中间值无法预测容量反应性。
  • 调整后IVCEE与容量反应性存在关系,但在IAP≥12 mmHg患者中该关系较弱。

证据类型、等级与局限

  • 证据类型:多中心诊断性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为IVCEE可能对指导液体治疗有一定附加价值,但不应单独用于液体预测。
  • 在IAP≥12 mmHg的机械通气休克患者中,IVCEE与容量反应性的关系较弱,解读结果时需考虑腹腔内压的影响。
  • 多数患者(300例,71%)IVCEE处于中间值,无法据此预测容量反应性。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

PURPOSE: We sought to determine the diagnostic ability of the end-expiratory inferior vena cava diameter (IVCEE) to predict fluid responsiveness (FR) and the potential confounding effect of intra-abdominal pressure (IAP).

METHODS: In this multicenter study, 540 consecutive ventilated patients with shock of various origins underwent an echocardiographic assessment by experts. The IVCEE, velocity time integral (VTI) of the left ventricular outflow tract (LVOT) and intra-abdominal pressure (IAP) were measured. Passive leg raising (PLR) was then systematically used to perform a reversible central blood volume expansion. FR was defined by an increase in LVOT VTI ≥ 10% after 1 min of PLR.

RESULTS: Since IVCEE was not obtained in 117 patients (22%), 423 were studied (septic shock: 56%), 129 of them (30%) having elevated IAP (≥ 12 mmHg) and 172 of them (41%) exhibiting FR. IVCEE ≤ 13 mm predicted FR with a specificity of at least 80% in 62 patients (15%), while IVCEE ≥ 25 mm predicted the absence of FR with a specificity of at least 80% in 61 patients (14%). In the remaining 300 patients (71%), the intermediate value of IVCEE did not allow predicting FR. An adjusted relationship between IVCEE and FR was observed while this relationship was less pronounced in patients with IAP ≥ 12 mmHg.

CONCLUSIONS: Measurement of IVCEE in ventilated patients is moderately feasible and poorly predicts FR, with IAP acting as a confounding factor. IVCEE might add some value to guide fluid therapy but should not be used alone for fluid prediction purposes.

来源:Intensive Care Med,查看原文。版权归原作者所有。

参考来源

  1. Vieillard-Baron A, Evrard B, Repessé X, et al. Limited value of end-expiratory inferior vena cava diameter to predict fluid responsiveness impact of intra-abdominal pressure. Intensive Care Med. 2018. PMID: 29356854. doi:10.1007/s00134-018-5067-2

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。