文献速递心脑血管急症重症综合管理与镇静镇痛

无创针与传统腰椎穿刺针的比较:系统评价与荟萃分析

Atraumatic versus conventional lumbar puncture needles: a systematic review and meta-analysis.
PubMed 文献 · Lancet · 2017-12-07
一句话结论在需要腰椎穿刺的患者中,无创针较传统针显著降低硬膜穿刺后头痛发生率(4.2% vs 11.0%,RR 0.40),且首次穿刺成功率等无差异。

该系统评价与荟萃分析检索13个数据库至2017年8月15日,纳入110项随机对照试验、共31412例接受腰椎穿刺的患者,比较无创针与传统针。主要终点硬膜穿刺后头痛发生率从传统针组的11.0%(95%CI 9.1-13.3)降至无创针组的4.2%(95%CI 3.3-5.2),RR 0.40(95%CI 0.34-0.47,p<0.0001,I²=45.4%)。无创针还显著减少静脉输液或控制性镇痛需求、硬膜外血补片需求、任何头痛、轻/重度头痛、神经根刺激和听力障碍,首次穿刺成功率、失败率、平均尝试次数、创伤性穿刺和背痛无显著差异。作者认为无创针是需腰椎穿刺患者的更优选择,证据质量高。

要点

  • 硬膜穿刺后头痛发生率:传统针组11.0%(95%CI 9.1-13.3)vs 无创针组4.2%(95%CI 3.3-5.2),RR 0.40(95%CI 0.34-0.47,p<0.0001,I²=45.4%)。
  • 无创针显著减少硬膜外血补片需求(RR 0.50,95%CI 0.33-0.75,p=0.001)和静脉输液或控制性镇痛需求(RR 0.44,95%CI 0.29-0.64,p<0.0001)。
  • 任何头痛(RR 0.50,95%CI 0.43-0.57)、轻度头痛(RR 0.52,95%CI 0.38-0.70)、重度头痛(RR 0.41,95%CI 0.28-0.59)、神经根刺激(RR 0.71,95%CI 0.54-0.92)、听力障碍(RR 0.25,95%CI 0.11-0.60)均显著减少。
  • 首次穿刺成功率、失败率、平均尝试次数、创伤性穿刺和背痛在两组间无显著差异。
  • 预设亚组分析显示针类型与患者年龄、性别、预防性静脉输液、针号、体位、穿刺指征、穿刺后卧床或临床专科无交互作用。

适用人群与场景

  • 接受任何腰椎穿刺指征的患者,来自110项随机对照试验、29个国家、共31412例参与者。
  • 排除无硬膜穿刺的硬膜外注射和没有传统针对照组的随机试验。

研究设计与关键结果

  • 系统评价与荟萃分析纳入110项随机对照试验(1989–2017年,29个国家,31412例),比较无创针与传统针用于腰椎穿刺。
  • 主要终点硬膜穿刺后头痛发生率:传统针组11.0%(95%CI 9.1-13.3)vs 无创针组4.2%(95%CI 3.3-5.2),RR 0.40(95%CI 0.34-0.47,p<0.0001;I²=45.4%)。
  • 无创针组需静脉输液或控制性镇痛的风险降低(RR 0.44,95%CI 0.29-0.64;p<0.0001),需硬膜外血补片的风险降低(RR 0.50,95%CI 0.33-0.75;p=0.001)。
  • 任何头痛(RR 0.50,95%CI 0.43-0.57;p<0.0001)、轻度头痛(RR 0.52,95%CI 0.38-0.70;p<0.0001)、重度头痛(RR 0.41,95%CI 0.28-0.59;p<0.0001)、神经根刺激(RR 0.71,95%CI 0.54-0.92;p=0.011)、听力障碍(RR 0.25,95%CI 0.11-0.60;p=0.002)在无创针组均显著减少。
  • 首次穿刺成功率、失败率、平均尝试次数、创伤性穿刺发生率和背痛在两组间无显著差异。
  • 预设亚组分析显示硬膜穿刺后头痛与针类型之间无交互作用(患者年龄、性别、预防性静脉输液、针号、体位、穿刺指征、穿刺后卧床、临床专科)。

证据类型、等级与局限

  • 证据类型:系统评价与荟萃分析,纳入110项随机对照试验。
  • 证据等级:采用GRADE评级为高质量证据。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在需要腰椎穿刺的患者中,无创针是更优选择,可降低硬膜穿刺后头痛发生率及因额外治疗返回医院的需求,且疗效与传统针相似。
  • 首次穿刺成功率、失败率、平均尝试次数、创伤性穿刺和背痛无显著差异,临床选择无创针不牺牲这些操作指标。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Atraumatic needles have been proposed to lower complication rates after lumbar puncture. However, several surveys indicate that clinical adoption of these needles remains poor. We did a systematic review and meta-analysis to compare patient outcomes after lumbar puncture with atraumatic needles and conventional needles.

METHODS: In this systematic review and meta-analysis, we independently searched 13 databases with no language restrictions from inception to Aug 15, 2017, for randomised controlled trials comparing the use of atraumatic needles and conventional needles for any lumbar puncture indication. Randomised trials comparing atraumatic and conventional needles in which no dural puncture was done (epidural injections) or without a conventional needle control group were excluded. We screened studies and extracted data from published reports independently. The primary outcome of postdural-puncture headache incidence and additional safety and efficacy outcomes were assessed by random-effects and fixed-effects meta-analysis. This study is registered with the International Prospective Register of Systematic Reviews, number CRD42016047546.

FINDINGS: We identified 20 241 reports; after exclusions, 110 trials done between 1989 and 2017 from 29 countries, including a total of 31 412 participants, were eligible for analysis. The incidence of postdural-puncture headache was significantly reduced from 11·0% (95% CI 9·1-13·3) in the conventional needle group to 4·2% (3·3-5·2) in the atraumatic group (relative risk 0·40, 95% CI 0·34-0·47, p<0·0001; I2=45·4%). Atraumatic needles were also associated with significant reductions in the need for intravenous fluid or controlled analgesia (0·44, 95% CI 0·29-0·64; p<0·0001), need for epidural blood patch (0·50, 0·33-0·75; p=0·001), any headache (0·50, 0·43-0·57; p<0·0001), mild headache (0·52, 0·38-0·70; p<0·0001), severe headache (0·41, 0·28-0·59; p<0·0001), nerve root irritation (0·71, 0·54-0·92; p=0·011), and hearing disturbance (0·25, 0·11-0·60; p=0·002). Success of lumbar puncture on first attempt, failure rate, mean number of attempts, and the incidence of traumatic tap and backache did not differ significantly between the two needle groups. Prespecified subgroup analyses of postdural-puncture headache revealed no interactions between needle type and patient age, sex, use of prophylactic intravenous fluid, needle gauge, patient position, indication for lumbar puncture, bed rest after puncture, or clinician specialty. These results were rated high-quality evidence as examined using the grading of recommendations assessment, development, and evaluation.

INTERPRETATION: Among patients who had lumbar puncture, atraumatic needles were associated with a decrease in the incidence of postdural-puncture headache and in the need for patients to return to hospital for additional therapy, and had similar efficacy to conventional needles. These findings offer clinicians and stakeholders a comprehensive assessment and high-quality evidence for the safety and efficacy of atraumatic needles as a superior option for patients who require lumbar puncture.

来源:Lancet,查看原文。版权归原作者所有。

参考来源

  1. Nath S, Koziarz A, Badhiwala JH, et al. Atraumatic versus conventional lumbar puncture needles: a systematic review and meta-analysis. Lancet. 2017. PMID: 29223694. doi:10.1016/S0140-6736(17)32451-0

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。