文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

无创正压通气时同步使用鼻导管的面罩漏气量:随机交叉试验

Face mask leak with nasal cannula during noninvasive positive pressure ventilation: A randomized crossover trial.
PubMed 文献 · Am J Emerg Med · 2017-12-06
一句话结论健康志愿者中,NPPV同步鼻导管15L/min不显著增加面罩漏气,可能有助于简化插管前气道管理。

该随机交叉非劣效性研究纳入64名健康志愿者,比较单纯无创正压通气(NPPV-a,10cmH2O持续气道正压)与NPPV同步鼻导管15L/min(NPPV-nc)各60秒试验。主要终点为60秒时间平均面罩漏气量,非劣效界值5L/min。结果NPPV-a漏气2.2L/min vs NPPV-nc漏气4.0L/min,差值1.7L/min(单侧95%CI -∞至3.2L/min),未超过非劣效界值。NPPV-a组分钟通气量(13.5 vs 12.2L)和呼吸频率(14.8 vs 13.5次/分)较高。作者认为同步鼻导管可能简化插管前接受NPPV患者的气道管理。

要点

  • 健康志愿者中,NPPV同步鼻导管15L/min的面罩漏气量为4.0L/min,单纯NPPV为2.2L/min,差值1.7L/min(单侧95%CI -∞至3.2L/min),未超过预设5L/min非劣效界值。
  • NPPV同步鼻导管时分钟通气量12.2L、呼吸频率13.5次/分,均低于单纯NPPV的13.5L和14.8次/分。
  • 作者认为,对插管前接受NPPV的患者,同步应用鼻导管可能是有助于简化气道管理的策略。
  • 该研究为健康志愿者随机交叉非劣效性试验,非劣效界值设为5L/min,主要终点为60秒时间平均面罩漏气量。

适用人群与场景

  • 健康志愿者,随机接受60秒NPPV试验(10cmH2O持续气道正压),先单纯NPPV或先NPPV同步鼻导管15L/min,休息后交叉接受另一干预。

处置流程与药物剂量

  • NPPV参数为10cmH2O持续气道正压,每次试验持续60秒;同步鼻导管流量为15L/min。
  • 主要终点为60秒时间平均面罩漏气量(L/min),非劣效界值为5L/min。

研究设计与关键结果

  • 随机交叉非劣效性试验纳入64名健康志愿者,比较单纯NPPV(NPPV-a)与NPPV同步鼻导管15L/min(NPPV-nc)。
  • 主要终点60秒时间平均面罩漏气量:NPPV-a组2.2L/min vs NPPV-nc组4.0L/min,差值1.7L/min(单侧95%CI -∞至3.2L/min),未超过5L/min非劣效界值。
  • NPPV-a组分钟通气量高于NPPV-nc组(13.5 vs 12.2L),呼吸频率也较高(14.8 vs 13.5次/分)。

证据类型、等级与局限

  • 证据类型:随机交叉非劣效性试验。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,对插管前接受NPPV的患者,同步应用鼻导管可能是有助于简化气道管理的策略。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Nasal cannula can achieve apneic oxygenation during emergency intubation. However, pre-procedure nasal cannula placement may be difficult in patients undergoing non-invasive positive pressure ventilation (NPPV) prior to intubation. Our objective was to compare mask leak during NPPV with versus without simultaneous application of nasal cannula. We hypothesized mask leak would be no worse with concomitant use of nasal cannula (non-inferiority design).

METHODS: We performed a randomized crossover non-inferiority study of healthy volunteers. We randomized subjects undergoing 60s trials of NPPV (10cmH2O continuous positive airway pressure) to either NPPV alone (NPPV-a) or NPPV with nasal cannula at 15L/min (NPPV-nc). After a brief rest period, all subjects underwent the alternative intervention. The primary outcome was time averaged mask leak over 60s (L/min). We defined a non-inferiority margin of 5L/min.

RESULTS: We enrolled 64 subjects. Mean time-averaged mask leak was 2.2L/min for NPPV-a versus 4.0L/min for NPPV-nc for a difference of 1.7L/min (one-sided 95% CI -∞ to 3.2L/min). NPPV-a resulted in higher mean minute volume received (13.5 versus 12.2L) and higher mean respiratory rates (14.8 versus 13.5 breaths per minute).

CONCLUSION: The addition of nasal cannula during NPPV does not significantly increase mask leak. The simultaneous application of nasal cannula with NPPV may be a useful strategy to streamline airway management among patients undergoing NPPV prior to intubation.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Brown DJ, Carroll SM, April MD, et al. Face mask leak with nasal cannula during noninvasive positive pressure ventilation: A randomized crossover trial. Am J Emerg Med. 2017. PMID: 29208322. doi:10.1016/j.ajem.2017.10.055

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。