锥形气管导管套囊预防呼吸机相关肺炎和早期术后肺炎:随机对照试验的系统评价与Meta分析
该系统评价与Meta分析检索MEDLINE、EMBASE、CENTRAL/CCTR、ClinicalTrials.gov和ICTRP至2017年3月,纳入6项随机对照试验共1324例ICU和术后病房患者,比较锥形套囊与标准套囊对医院获得性肺炎的影响。仅2项研究同时应用声门下分泌物引流,无试验进行连续套囊压力监测。锥形套囊组与标准套囊组医院获得性肺炎发生率无显著差异(OR 0.97,95%CI 0.73-1.28,P=0.81),次要结局亦无差异。作者认为需进一步研究锥形套囊联合连续套囊压力监测和声门下分泌物引流的效应。
要点
- 在ICU和术后患者中,锥形套囊与标准套囊的医院获得性肺炎发生率无显著差异(OR 0.97,95%CI 0.73-1.28,P=0.81)。
- 共纳入6项随机对照试验、1324例患者,来自ICU和术后病房。
- 仅2项研究同时应用声门下分泌物引流,无试验进行连续套囊压力监测。
- 死亡率、机械通气时间、住院和ICU停留时间及套囊充气不足等次要结局均无差异。
- 作者认为需进一步研究锥形套囊联合连续套囊压力监测和声门下分泌物引流的效应。
适用人群与场景
- 纳入ICU和术后病房的成人患者,比较锥形套囊与标准套囊对医院获得性肺炎的影响。
研究设计与关键结果
- 研究类型为随机对照试验的系统评价与Meta分析,纳入6项随机对照试验共1324例患者,来自ICU和术后病房。
- 主要终点医院获得性肺炎发生率:锥形套囊组与标准套囊组无显著差异(OR 0.97,95%CI 0.73-1.28,P=0.81)。
- 次要终点死亡率、机械通气时间、住院和ICU停留时间及套囊充气不足均无差异。
- 仅2项研究同时应用声门下分泌物引流,无试验进行连续套囊压力监测。
证据类型、等级与局限
- 证据类型为随机对照试验的系统评价与Meta分析。
- 局限:仅2项研究同时应用声门下分泌物引流,无试验进行连续套囊压力监测;作者结论指出需进一步研究锥形套囊联合连续套囊压力监测和声门下分泌物引流的效应。
对床旁实践的改变
- 在ICU和术后患者中,使用锥形套囊与标准套囊的医院获得性肺炎发生率无显著差异(OR 0.97,95%CI 0.73-1.28)。
- 作者认为需进一步研究锥形套囊联合连续套囊压力监测和声门下分泌物引流的效应。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: Microaspiration of subglottic secretions is considered a major pathogenic mechanism of hospital-acquired pneumonia, either early postoperative or ventilator-associated pneumonia. Tapered endotracheal tube cuffs have been proposed to provide a better seal of the extraluminal airway, thereby preventing microaspiration and possibly hospital-acquired pneumonia. We performed a systematic review and meta-analysis to assess the value of endotracheal tubes with tapered cuffs in the prevention of hospital-acquired pneumonia.
DATA SOURCES: A systematic search of MEDLINE, EMBASE, CENTRAL/CCTR, ClinicalTrials.gov, and ICTRP was conducted up to March 2017.
STUDY SELECTION: Eligible trials were randomized controlled clinical trials comparing the impact of tapered cuffs versus standard cuffs on hospital-acquired pneumonia.
DATA EXTRACTION: Random-effects meta-analysis calculated odds ratio and 95% CI for hospital-acquired pneumonia occurrence rate between groups. Secondary outcome measures included mortality, duration of mechanical ventilation, length of hospital and ICU stay, and cuff underinflation.
DATA SYNTHESIS: Six randomized controlled clinical trials with 1,324 patients from intensive care and postoperative wards were included. Only two studies concomitantly applied subglottic secretion drainage, and no trial performed continuous cuff pressure monitoring. No significant difference in hospital-acquired pneumonia incidence per patient was found when tapered cuffs were compared with standard cuffs (odds ratio, 0.97; 95% CI, [0.73-1.28]; p = 0.81). There were likewise no differences in secondary outcomes.
CONCLUSIONS: Application of tapered endotracheal tube cuffs did not reduce hospital-acquired pneumonia incidence among ICU and postoperative patients. Further research should examine the impact of concomitant use of tapered cuffs with continuous cuff pressure monitoring and subglottic secretion drainage.
参考来源
- Maertens B, Blot K, Blot S, et al. Prevention of Ventilator-Associated and Early Postoperative Pneumonia Through Tapered Endotracheal Tube Cuffs: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. Crit Care Med. 2018. PMID: 29206767. doi:10.1097/CCM.0000000000002889
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。