文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

柏林ARDS定义观察者间信度及提高ARDS诊断信度的策略

Interobserver Reliability of the Berlin ARDS Definition and Strategies to Improve the Reliability of ARDS Diagnosis.
PubMed 文献 · Chest · 2017-12-14
一句话结论柏林ARDS定义观察者间信度中等(κ=0.50),67%分歧源于胸部影像判读差异,三位临床医生独立复核可将信度提升至较高水平(κ=0.75)。

该研究纳入4个ICU的205例低氧性呼吸衰竭患者,由3名临床医生独立评估是否符合柏林ARDS定义、诊断信心、各条标准是否满足及满足时间。ARDS诊断的观察者间信度为中等(κ=0.50;95%CI 0.40-0.59)。同一患者复核医生间67%的诊断分歧由胸部影像判读差异解释,其他标准贡献较小(识别ARDS危险因素15%;心脏性水肿/容量负荷过重排除7%)。合并3名临床医生的独立复核可将信度提升至较高水平(κ=0.75;95%CI 0.68-0.80)。当一名医生以高信心诊断ARDS时,其他医生72%的复核同意该诊断。若ARDS在入院48小时内发生,医生间对满足全部ARDS标准的时间高度一致(中位差5小时)。作者认为提高胸部影像判读方法或多医生独立复核是提高ARDS诊断信度的重要策略。

要点

  • 柏林ARDS定义的观察者间信度为中等(κ=0.50;95%CI 0.40-0.59),诊断不一致可能影响临床试验与临床识别。
  • 同一患者医生间67%的诊断分歧源于胸部影像判读差异,识别危险因素占15%,排除心脏性水肿/容量负荷过重占7%。
  • 合并3名临床医生的独立复核可将信度提升至较高水平(κ=0.75;95%CI 0.68-0.80)。
  • 一名医生以高信心诊断ARDS时,其他医生72%的复核同意该诊断。
  • ARDS在入院48小时内发生时,医生间对满足全部标准的时间高度一致(中位差5小时)。

适用人群与场景

  • 4个ICU的205例低氧性呼吸衰竭患者,由3名临床医生独立复核是否符合柏林ARDS定义。

诊断标准与关键阈值

  • 柏林ARDS定义:评估患者是否满足各条标准,包括识别ARDS危险因素、胸部影像判读、排除心脏性水肿/容量负荷过重,以及满足全部标准的时间。

研究设计与关键结果

  • 研究类型:观察者间信度研究;样本量205例低氧性呼吸衰竭患者,来自4个ICU;由3名临床医生独立复核。
  • ARDS诊断观察者间信度为中等(κ=0.50;95%CI 0.40-0.59)。
  • 同一患者医生间67%的诊断分歧由胸部影像判读差异解释,识别ARDS危险因素占15%,心脏性水肿/容量负荷过重排除占7%。
  • 合并3名临床医生独立复核可将信度提升至较高水平(κ=0.75;95%CI 0.68-0.80)。
  • 一名医生以高信心诊断ARDS时,其他医生72%的复核同意该诊断。
  • ARDS在入院48小时内发生时,医生间对满足全部ARS标准的时间高度一致(中位差5小时)。

证据类型、等级与局限

  • 证据类型:观察者间信度研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,合并多名临床医生的独立复核或改进识别胸部影像双肺浸润的方法,是提高ARDS诊断信度的重要策略。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Failure to reliably diagnose ARDS may be a major driver of negative clinical trials and underrecognition and treatment in clinical practice. We sought to examine the interobserver reliability of the Berlin ARDS definition and examine strategies for improving the reliability of ARDS diagnosis.

METHODS: Two hundred five patients with hypoxic respiratory failure from four ICUs were reviewed independently by three clinicians, who evaluated whether patients had ARDS, the diagnostic confidence of the reviewers, whether patients met individual ARDS criteria, and the time when criteria were met.

RESULTS: Interobserver reliability of an ARDS diagnosis was "moderate" (kappa = 0.50; 95% CI, 0.40-0.59). Sixty-seven percent of diagnostic disagreements between clinicians reviewing the same patient was explained by differences in how chest imaging studies were interpreted, with other ARDS criteria contributing less (identification of ARDS risk factor, 15%; cardiac edema/volume overload exclusion, 7%). Combining the independent reviews of three clinicians can increase reliability to "substantial" (kappa = 0.75; 95% CI, 0.68-0.80). When a clinician diagnosed ARDS with "high confidence," all other clinicians agreed with the diagnosis in 72% of reviews. There was close agreement between clinicians about the time when a patient met all ARDS criteria if ARDS developed within the first 48 hours of hospitalization (median difference, 5 hours).

CONCLUSIONS: The reliability of the Berlin ARDS definition is moderate, driven primarily by differences in chest imaging interpretation. Combining independent reviews by multiple clinicians or improving methods to identify bilateral infiltrates on chest imaging are important strategies for improving the reliability of ARDS diagnosis.

来源:Chest,查看原文。版权归原作者所有。

参考来源

  1. Sjoding MW, Hofer TP, Co I, et al. Interobserver Reliability of the Berlin ARDS Definition and Strategies to Improve the Reliability of ARDS Diagnosis. Chest. 2017. PMID: 29248620. doi:10.1016/j.chest.2017.11.037

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。