文献速递心脑血管急症重症综合管理与镇静镇痛

D-二聚体与组织因子-1208D/I基因多态性对非体外循环冠状动脉旁路移植术患者预后的影响

[Effect of D-dimer and tissue factor-1208D/I gene polymorphism on the prognosis of patients with off-pump coronary artery bypass grafting].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2017-01-01
一句话结论非体外循环冠状动脉旁路移植术后高凝状态持续约3个月,LVEF<0.50与TF-1208II基因型是术后1年心绞痛复发的独立危险因素。

该回顾性分析纳入2015年5月至2016年5月天津医科大学总医院首次行非体外循环冠状动脉旁路移植术(OPCABG)的患者,记录围术期指标、不同时点D-二聚体水平及1年随访预后。结果显示血浆D-二聚体术后持续升高,术后1个月达峰值[1.94(1.07,2.70)mg/L],术后3个月降至术前水平[0.20(0.10,0.45)mg/L]。TF-1208II基因型患者术后14天和1个月D-二聚体水平显著高于TF-1208DD和TF-1208D/I基因型组。1年随访25例复发心绞痛,无心肌梗死;TF-1208II基因型心绞痛复发比例显著高于其他两型。Logistic回归显示LVEF<0.50(OR=6.482,95%CI 1.365-18.763,P=0.015)和TF-1208II基因型(OR=8.864,95%CI 1.613-46.743,P=0.012)是术后1年心绞痛复发的独立危险因素。

要点

  • OPCABG术后血浆D-二聚体持续升高,术后1个月达峰值1.94(1.07,2.70)mg/L,术后3个月降至术前水平0.20(0.10,0.45)mg/L。
  • TF-1208II基因型患者术后14天D-二聚体为4.17(1.54,5.09)mg/L,高于TF-1208DD的1.91(1.07,2.26)mg/L和TF-1208D/I的1.02(0.91,1.88)mg/L(均P<0.05)。
  • TF-1208II基因型患者术后1个月D-二聚体为5.12(2.41,6.32)mg/L,高于TF-1208DD的1.94(1.18,2.70)mg/L和TF-1208D/I的1.62(0.22,1.88)mg/L(均P<0.05)。
  • 1年随访25例复发心绞痛、无心肌梗死,TF-1208II基因型心绞痛复发比例显著高于TF-1208DD和TF-1208D/I基因型组(χ2=0.197,P=0.004)。
  • LVEF<0.50(OR=6.482,95%CI 1.365-18.763,P=0.015)和TF-1208II基因型(OR=8.864,95%CI 1.613-46.743,P=0.012)是OPCABG术后1年心绞痛复发的独立危险因素。

适用人群与场景

  • 2015年5月至2016年5月天津医科大学总医院收治的首次行非体外循环冠状动脉旁路移植术(OPCABG)患者。

研究设计与关键结果

  • 研究类型为回顾性分析,纳入首次行OPCABG患者的病例资料。
  • 记录一般资料、手术时间、旁路移植血管数、LVEF、24小时胸腔引流量、术中肝素用量、联合抗凝及抗血小板时间、术后呼吸机使用时间。
  • 检测术后1、4、7、14天及1、2、3个月血液生化指标,记录围术期并发症、不同TF-1208D/I基因型患者D-二聚体水平及1年随访预后。
  • 血浆D-二聚体术后持续升高,术后1个月达峰值1.94(1.07,2.70)mg/L,随后下降,术后3个月降至术前水平0.20(0.10,0.45)mg/L。
  • 术后14天TF-1208II基因型D-二聚体为4.17(1.54,5.09)mg/L,高于TF-1208DD的1.91(1.07,2.26)mg/L和TF-1208D/I的1.02(0.91,1.88)mg/L,均P<0.05。
  • 术后1个月TF-1208II基因型D-二聚体为5.12(2.41,6.32)mg/L,高于TF-1208DD的1.94(1.18,2.70)mg/L和TF-1208D/I的1.62(0.22,1.88)mg/L,均P<0.05。
  • 1年随访25例复发心绞痛、无心肌梗死发生;TF-1208II基因型心绞痛复发比例显著高于TF-1208DD和TF-1208D/I基因型组(χ2=0.197,P=0.004)。
  • Logistic回归显示LVEF<0.50(OR=6.482,95%CI 1.365-18.763,P=0.015)和TF-1208II基因型(OR=8.864,95%CI 1.613-46.743,P=0.012)是术后1年心绞痛复发的独立危险因素。

证据类型、等级与局限

  • 证据类型:回顾性分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为OPCABG术后机体处于高凝状态并持续较长时间,术后约3个月几乎恢复。
  • 作者认为LVEF<0.50和TF-1208II基因型是术后1年心绞痛复发的独立危险因素。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the effect of perioperative period D-dimer and tissue factor (TF)-1208D/I gene polymorphism on the long-term prognosis of patients with off-pump coronary artery bypass grafting (OPCABG).

METHODS: Retrospective analysis of the case data of the first OPCABG patients admitted to Tianjin Medical University General Hospital from May 2015 to May 2016 were enrolled. The general data, operation time, bypass number, left ventricular ejection fraction (LVEF), flow rate of 24-hour pleural effusion, intraoperative heparin dosage, combined anticoagulant and antiplatelet time, and the time of postoperative ventilator were measured. The blood biochemical indexes of 1, 4, 7, 14 days and 1, 2, 3 months after operation, perioperative complications, the level of D-dimer in the patients with different TF-1208D/I gene polymorphism, and prognosis of 1-year follow-up were recorded. The risk factors of recurrent angina 1 year after operation was analyzed by Logistic regression analysis.

RESULTS: The level of plasma D-dimer was increased continuously after OPCABG, and reached a peak at 1 month after operation [1.94 (1.07, 2.70) mg/L], then decreased, and decreased to preoperative level 3 months after operation [0.20 (0.10, 0.45) mg/L]. The level of D-dimer in TF-1208II genotype was significantly higher than that in TF-1208DD genotype and TF-1208D/I genotype group at 14 days and 1 month after operation [mg/L: 4.17 (1.54, 5.09) vs. 1.91 (1.07, 2.26), 1.02 (0.91, 1.88) at 14 days; 5.12 (2.41, 6.32) vs. 1.94 (1.18, 2.70), 1.62 (0.22,1.88) at 1 month, all P < 0.05]. The results of 1-year follow-up showed that 25 patients with recurrent angina pectoris without the occurrence of myocardial infarction. The proportion of recurrent angina pectoris in TF-1208II genotype was significantly higher than that in TF-1208DD genotype and TF-1208D/I genotype group (χ2 = 0.197, P = 0.004). Logistic regression analysis showed that LVEF < 0.50 [odds ratio (OR) = 6.482, 95% confidence interval (95%CI) = 1.365-18.763, P = 0.015] and TF-1208II genotype (OR = 8.864, 95%CI = 1.613-46.743, P = 0.012) were independent risk factors for recurrent angina pectoris at 1 year after OPCABG.

CONCLUSIONS: After OPCABG, the body was in a hypercoagulable state and lasted for a long time, and almost recovered 3 months after operation. LVEF < 0.50 and TF-1208 II genotype were independent risk factors of angina pectoris at 1 year after surgery.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Wang Z, Qian Z, Ren J, et al. [Effect of D-dimer and tissue factor-1208D/I gene polymorphism on the prognosis of patients with off-pump coronary artery bypass grafting]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2017. PMID: 29216943. doi:10.3760/cma.j.issn.2095-4352.2017.12.009

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。