急性主动脉夹层的临床检查:系统评价与Meta分析
该系统评价检索PubMed、MEDLINE、Embase和Cochrane数据库(1968年至2016年7月),纳入9项研究共2400例参与者。主动脉夹层患病率范围为21.9%至76.1%(均值±标准差=39.1%±17.1%)。增加夹层概率的临床发现为神经功能缺损(特异度95%,阳性似然比=4.4,95%CI=3.3-5.7)和低血压(特异度95%,阳性似然比=2.9,95%CI=1.8-4.6);降低概率的为纵隔未增宽(敏感度76%-95%,阴性似然比=0.14-0.60)和AHA ADD风险评分<1分(敏感度91%,阴性似然比=0.22,95%CI=0.15-0.33)。作者认为,结合高危和低危特征的临床整体判断以及缺乏替代诊断应驱动对急性主动脉夹层的检查。
要点
- 低血压(特异度95%,阳性似然比=2.9,95%CI=1.8-4.6)和神经功能缺损(特异度95%,阳性似然比=4.4,95%CI=3.3-5.7)增加急性主动脉夹层概率。
- 纵隔未增宽降低夹层概率(敏感度76%-95%,阴性似然比=0.14-0.60)。
- AHA ADD风险评分<1分降低夹层概率(敏感度91%,阴性似然比=0.22,95%CI=0.15-0.33)。
- 纳入9项研究共2400例参与者,夹层患病率范围21.9%至76.1%(均值±标准差=39.1%±17.1%)。
- 作者认为,结合高危和低危特征的临床整体判断及缺乏替代诊断应驱动对急性主动脉夹层的检查。
适用人群与场景
- 疑似急性主动脉夹层的急诊患者(纳入9项研究共2400例参与者)
诊断标准与关键阈值
- AHA ADD风险评分<1分:敏感度91%,阴性似然比=0.22(95%CI=0.15-0.33),降低急性主动脉夹层概率。
红旗征与不能漏的情况
- 低血压:特异度95%,阳性似然比=2.9(95%CI=1.8-4.6),增加急性主动脉夹层概率。
- 神经功能缺损:特异度95%,阳性似然比=4.4(95%CI=3.3-5.7),增加急性主动脉夹层概率。
研究设计与关键结果
- 系统评价与Meta分析:检索PubMed、MEDLINE、Embase和Cochrane数据库(1968年至2016年7月),最终纳入9项研究共2400例参与者,QUADAS-2低偏倚风险,全文筛选kappa=0.89。
- 主动脉夹层患病率范围21.9%至76.1%(均值±标准差=39.1%±17.1%)。
- 神经功能缺损(n=3)特异度95%,阳性似然比=4.4(95%CI=3.3-5.7),I²=0%。
- 低血压(n=4)特异度95%,阳性似然比=2.9(95%CI=1.8-4.6),I²=42%。
- 纵隔未增宽(n=4)敏感度76%-95%,阴性似然比=0.14-0.60,I²=93%。
- AHA ADD风险评分<1分(n=1)敏感度91%,阴性似然比=0.22(95%CI=0.15-0.33)。
证据类型、等级与局限
- 证据类型:系统评价与Meta分析(纳入9项研究,共2400例参与者),采用QUADAS-2工具评估研究质量,双变量随机效应Meta分析。
- 局限:纵隔未增宽分析的异质性I²=93%。
对床旁实践的改变
- 作者认为,低血压、脉搏异常或神经功能缺损应提高对急性主动脉夹层的怀疑。
- 作者认为,AHA ADD风险评分<1分降低对急性主动脉夹层的怀疑。
- 作者认为,结合高危和低危特征的临床整体判断以及缺乏替代诊断应驱动对急性主动脉夹层的检查。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: Acute aortic dissection is a life-threatening condition due to a tear in the aortic wall. It is difficult to diagnose and if missed carries a significant mortality.
METHODS: We conducted a librarian-assisted systematic review of PubMed, MEDLINE, Embase, and the Cochrane database from 1968 to July 2016. Titles and abstracts were reviewed and data were extracted by two independent reviewers (agreement measured by kappa). Studies were combined if low clinical and statistical heterogeneity (I2 < 30%). Study quality was assessed using the QUADAS-2 tool. Bivariate random effects meta analyses using Revman 5 and SAS 9.3 were performed.
RESULTS: We identified 792 records: 60 were selected for full text review, nine studies with 2,400 participants were included (QUADAS-2 low risk of bias, κ = 0.89 [for full-text review]). Prevalence of aortic dissection ranged from 21.9% to 76.1% (mean ± SD = 39.1% ± 17.1%). The clinical findings increasing probability of aortic dissection were 1) neurologic deficit (n = 3, specificity = 95%, positive likelihood ratio [LR+] = 4.4, 95% confidence interval [CI] = 3.3-5.7, I2 = 0%) and 2) hypotension (n = 4, specificity = 95%, LR+ = 2.9 95% CI = 1.8-4.6, I2 = 42%), and decreasing probability were the absence of a widened mediastinum (n = 4, sensitivity = 76%-95%, negative likelihood ratio [LR-] = 0.14-0.60, I2 = 93%) and an American Heart Association aortic dissection detection (AHA ADD) risk score < 1 (n = 1, sensitivity = 91%, LR- = 0.22, 95% CI = 0.15-0.33).
CONCLUSIONS: Suspicion for acute aortic dissection should be raised with hypotension, pulse, or neurologic deficit. Conversely, a low AHA ADD score decreases suspicion. Clinical gestalt informed by high- and low-risk features together with an absence of an alternative diagnosis should drive investigation for acute aortic dissection.
参考来源
- Ohle R, Kareemi HK, Wells G, et al. Clinical Examination for Acute Aortic Dissection: A Systematic Review and Meta-analysis. Acad Emerg Med. 2018. PMID: 29265487. doi:10.1111/acem.13360
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。