急诊医师执行扩展聚焦腹部创伤超声(E-FAST)与CT诊断准确性的比较
本研究为前瞻性观察性诊断准确性研究,在一级创伤中心急诊科纳入连续成人多发伤患者,最终腹部分析132例、胸部分析130例。以CT为金标准,E-FAST诊断腹腔游离液的AUC为0.71,气胸为0.87,胸腔积液为1.00。腹腔游离液的敏感性42.9%、特异性98.4%,阳性似然比26.8、阴性似然比0.58。作者结论认为E-FAST特异性极佳,但敏感性不足以排除胸腹部损伤。
要点
- 急诊医师执行的E-FAST诊断腹腔游离液敏感性仅42.9%、特异性98.4%,+LR 26.8、-LR 0.58。
- E-FAST诊断气胸的AUC为0.87,诊断胸腔积液的AUC为1.00,诊断腹腔游离液的AUC为0.71。
- E-FAST特异性极佳,但敏感性不高,不能用于排除创伤患者的胸腹部损伤。
- 研究为前瞻性观察性诊断准确性研究,在一级创伤中心急诊科进行,最终腹部分析132例、胸部分析130例。
适用人群与场景
- 在一级创伤中心急诊科就诊的连续成人多发伤患者,且已开具胸腹部CT检查者被纳入。
- 血流动力学不稳定和无法配合的患者被排除。
研究设计与关键结果
- 研究类型为前瞻性观察性诊断准确性研究,在一级创伤中心急诊科进行,从144例合格患者中招募140例,最终腹部分析132例、胸部分析130例。
- 以CT(盲法学术放射科医师判读)为金标准,E-FAST诊断腹腔游离液的AUC为0.71,气胸为0.87,胸腔积液为1.00。
- E-FAST诊断腹腔游离液的敏感性42.9%、特异性98.4%,+LR为26.8,-LR为0.58。
证据类型、等级与局限
- 证据类型为前瞻性观察性诊断准确性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 急诊医师执行的E-FAST特异性极佳,但敏感性不足以排除创伤患者的胸腹部损伤,作者结论认为不能用于排除胸腹部损伤。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
INTRODUCTION: The diagnostic accuracy of the FAST exam performed by EM residents were shown to be similar to radiology residents. However, in the last 2 decades, an extended-FAST (E-FAST) protocol including thoracic examination to exclude pneumo- and hemothorax was introduced. The accuracy of emergency physicians (EPs) while performing E-FAST is a less studied area, especially in Europe. The aim of this study was to compare the diagnostic accuracy of the E-FAST exam performed by EM residents with the results of CT scan as a gold standard.
METHODS: This was a prospective, observational, diagnostic accuracy study conducted at the ED of a Level 1 Trauma Center. All consecutive adult multiple trauma patients were eligible, and any patient in whom thoraco-abdominal CT was ordered were recruited. Unstable and unavailable patients were excluded. E-FAST examination was performed by EPs as the index test, and CT examinations reported by a blinded academic radiology faculty was the gold standard.
RESULTS: A total of 140 patients were recruited from eligible 144 patients. The final study population was 132 for abdominal and 130 for thorax examinations. In this study, AUC of E-FAST was 0.71 for abdominal free fluid, 0.87 for pneumothorax and 1.00 for pleural effusion. The sensitivity was 42.9% and specificity was 98.4%. The +LR for abdominal free fluid was 26.8 and -LR was 0.58.
CONCLUSION: E-FAST examination has an excellent specificity. However, the sensitivity of the test is not high enough to rule-out thoraco-abdominal injuries in trauma patients when performed by EPs.
参考来源
- Akoglu H, Celik OF, Celik A, et al. Diagnostic accuracy of the Extended Focused Abdominal Sonography for Trauma (E-FAST) performed by emergency physicians compared to CT. Am J Emerg Med. 2017. PMID: 29146418. doi:10.1016/j.ajem.2017.11.019
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。