急诊医师执行扩展聚焦腹部创伤超声(E-FAST)与CT诊断准确性的比较

Diagnostic accuracy of the Extended Focused Abdominal Sonography for Trauma (E-FAST) performed by emergency physicians compared to CT.
PubMed 文献 · Am J Emerg Med · 2017-11-08
一句话结论急诊医师执行的E-FAST特异性极佳,但敏感性不足,不能用于排除创伤患者的胸腹部损伤。

本研究为前瞻性观察性诊断准确性研究,在一级创伤中心急诊科纳入连续成人多发伤患者,最终腹部分析132例、胸部分析130例。以CT为金标准,E-FAST诊断腹腔游离液的AUC为0.71,气胸为0.87,胸腔积液为1.00。腹腔游离液的敏感性42.9%、特异性98.4%,阳性似然比26.8、阴性似然比0.58。作者结论认为E-FAST特异性极佳,但敏感性不足以排除胸腹部损伤。

要点

  • 急诊医师执行的E-FAST诊断腹腔游离液敏感性仅42.9%、特异性98.4%,+LR 26.8、-LR 0.58。
  • E-FAST诊断气胸的AUC为0.87,诊断胸腔积液的AUC为1.00,诊断腹腔游离液的AUC为0.71。
  • E-FAST特异性极佳,但敏感性不高,不能用于排除创伤患者的胸腹部损伤。
  • 研究为前瞻性观察性诊断准确性研究,在一级创伤中心急诊科进行,最终腹部分析132例、胸部分析130例。

适用人群与场景

  • 在一级创伤中心急诊科就诊的连续成人多发伤患者,且已开具胸腹部CT检查者被纳入。
  • 血流动力学不稳定和无法配合的患者被排除。

研究设计与关键结果

  • 研究类型为前瞻性观察性诊断准确性研究,在一级创伤中心急诊科进行,从144例合格患者中招募140例,最终腹部分析132例、胸部分析130例。
  • 以CT(盲法学术放射科医师判读)为金标准,E-FAST诊断腹腔游离液的AUC为0.71,气胸为0.87,胸腔积液为1.00。
  • E-FAST诊断腹腔游离液的敏感性42.9%、特异性98.4%,+LR为26.8,-LR为0.58。

证据类型、等级与局限

  • 证据类型为前瞻性观察性诊断准确性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 急诊医师执行的E-FAST特异性极佳,但敏感性不足以排除创伤患者的胸腹部损伤,作者结论认为不能用于排除胸腹部损伤。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: The diagnostic accuracy of the FAST exam performed by EM residents were shown to be similar to radiology residents. However, in the last 2 decades, an extended-FAST (E-FAST) protocol including thoracic examination to exclude pneumo- and hemothorax was introduced. The accuracy of emergency physicians (EPs) while performing E-FAST is a less studied area, especially in Europe. The aim of this study was to compare the diagnostic accuracy of the E-FAST exam performed by EM residents with the results of CT scan as a gold standard.

METHODS: This was a prospective, observational, diagnostic accuracy study conducted at the ED of a Level 1 Trauma Center. All consecutive adult multiple trauma patients were eligible, and any patient in whom thoraco-abdominal CT was ordered were recruited. Unstable and unavailable patients were excluded. E-FAST examination was performed by EPs as the index test, and CT examinations reported by a blinded academic radiology faculty was the gold standard.

RESULTS: A total of 140 patients were recruited from eligible 144 patients. The final study population was 132 for abdominal and 130 for thorax examinations. In this study, AUC of E-FAST was 0.71 for abdominal free fluid, 0.87 for pneumothorax and 1.00 for pleural effusion. The sensitivity was 42.9% and specificity was 98.4%. The +LR for abdominal free fluid was 26.8 and -LR was 0.58.

CONCLUSION: E-FAST examination has an excellent specificity. However, the sensitivity of the test is not high enough to rule-out thoraco-abdominal injuries in trauma patients when performed by EPs.

来源:Am J Emerg Med,查看原文。版权归原作者所有。