机械通气对慢性阻塞性肺疾病急性加重患者膈肌收缩功能的影响
前瞻性研究纳入21例AECOPD机械通气患者(最终17例完成),用食管胃气囊导管测Pdi max。Pdi max随机械通气时间进行性下降,7天较3天显著降低(20.2±4.2 vs 28.1±4.4 cmH2O,P<0.01),11天时较第1天下降约38.7%(19.8±4.7 vs 32.3±3.9 cmH2O,P<0.01)。撤机困难组平均Pdi max及拔管前Pdi max均低于撤机成功组。Pdi max与CRP显著负相关,与白蛋白、前白蛋白显著正相关。拔管前Pdi max预测撤机成功的AUC为0.902,界值23.2 cmH2O时敏感度81.8%、特异度100%。
要点
- AECOPD机械通气患者Pdi max随时间进行性下降,11天时较第1天下降约38.7%(19.8±4.7 vs 32.3±3.9 cmH2O,P<0.01)。
- 拔管前Pdi max在撤机困难组低于撤机成功组(16.9±2.8 vs 26.8±6.6 cmH2O,P<0.01)。
- 拔管前Pdi max预测撤机成功AUC 0.902,界值23.2 cmH2O时敏感度81.8%、特异度100%。
- Pdi max与CRP显著负相关(r=-0.799,P=0.000),与白蛋白(r=0.613,P=0.008)及前白蛋白(r=0.661,P=0.004)显著正相关。
适用人群与场景
- 2015年2月至2017年5月同济大学附属上海市东方医院ICU收治的AECOPD接受机械通气患者,共21例纳入,最终17例完成研究方案。
研究设计与关键结果
- 前瞻性研究,纳入21例AECOPD机械通气患者,2例行气管切开、2例退出,最终17例纳入研究方案,其中6例死亡、11例成功拔管。
- 17例患者机械通气期间平均Pdi max随时间进行性下降,机械通气1-2天Pdi max无显著变化;7天时平均Pdi max显著低于3天时(20.2±4.2 vs 28.1±4.4 cmH2O,P<0.01)。
- 至机械通气11天评估结束时,平均Pdi max较机械通气第1天下降约38.7%(19.8±4.7 vs 32.3±3.9 cmH2O,P<0.01)。
- 机械通气期间CRP、白蛋白和前白蛋白呈下降趋势。
- 撤机困难组平均Pdi max及拔管前Pdi max均低于撤机成功组(平均Pdi max:25.2±5.4 vs 28.9±5.8 cmH2O;拔管前Pdi max:16.9±2.8 vs 26.8±6.6 cmH2O,均P<0.01)。
- Pdi max与CRP呈显著负相关(r=-0.799,P=0.000),与血清白蛋白(r=0.613,P=0.008)及前白蛋白(r=0.661,P=0.004)呈显著正相关。
- ROC曲线分析显示,拔管前Pdi max预测AECOPD患者撤机成功的AUC为0.902,界值23.2 cmH2O时敏感度81.8%、特异度100%。
证据类型、等级与局限
- 证据类型:前瞻性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为Pdi max可作为预测AECOPD机械通气患者成功拔管的参数。
- 机械通气以时间依赖方式诱导AECOPD患者膈肌收缩力下降,提示机械通气期间需关注膈肌功能变化。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To study diaphragmatic strength in patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD) during mechanical ventilation (MV), and to explore the predictive value of maximal transdiaphragm pressure (Pdi max) for successful extubation.
METHODS: A prospective study was conducted. Twenty-one patients with AECOPD receiving MV admitted to intensive care unit (ICU) of Shanghai East Hospital of Tongji University of School Medicine from February 2015 to May 2017 were enrolled. Pdi max value was measured by using esophageal and gastric balloon catheters within 24 hours of intubation until the day the patient underwent extubation or died. In addition, the C-reactive protein (CRP), serum albumin (Alb) and prealbumin (PA) during MV were recorded. Pearson correlation was used to analyze the correlations between Pdi max and CRP, Alb and PA. The receiver operating characteristic curve (ROC) was used to cumulate Pdi max value of the successful weaning.
RESULTS: Tracheotomy was done in 2 patients, and 2 patients quit the study. The remaining 17 patients were included in the investigative protocol. Six of the 17 patients died and 11 patients were successfully extubated. (1) Mean Pdi max decreased progressively over time in 17 patients of AECOPD during MV. There were no significant changes in Pdi max at 1-2 days of MV. Mean Pdi max at 7 days was significantly lower than that at 3 days [cmH2O (1 cmH2O = 0.098 kPa): 20.2±4.2 vs. 28.1±4.4, P < 0.01]. By the end of the evaluation period at 11 days of MV, mean Pdi max decreased about 38.7% to the 1 day of MV (cmH2O: 19.8±4.7 vs. 32.3±3.9, P < 0.01). During MV, CRP, Alb and PA showed a downward trend. (2) Mean Pdi max and the Pdi max before extubation in patients with difficulty extubation from MV was lower than that in successful weaning [Mean Pdi max (cmH2O): 25.2±5.4 vs. 28.9±5.8, Pdi max before extubation (cmH2O): 16.9±2.8 vs. 26.8±6.6, both P < 0.01]. (3) There was significantly negative correlation between Pdi max value and CRP (r = -0.799, P = 0.000). There was significantly positive correlation between Pdi max value and serum Alb (r = 0.613, P = 0.008) and PA (r = 0.661, P = 0.004). (4) ROC curve analysis showed that the area under the ROC curve (AUC) for predicting weaning success in the patients with AECOPD was 0.902. The sensitivity of the diagnosis was 81.8% and the specificity was 100% when cut-off value of Pdi max was 23.2 cmH2O.
CONCLUSIONS: MV induced the reduction of diaphragmatic contractility in a time-dependent manner. The Pdi max in patients with difficult extubation from MV was lower than that in successful weaning. The Pdi max could be a parameter to predict the successful extubation in patients with AECOPD during MV.
参考来源
- Wang F, Zhu X, Zhang C, et al. [Effects of mechanical ventilation on diaphragmatic contractile function in patients with AECOPD]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2017. PMID: 29151413. doi:10.3760/cma.j.issn.2095-4352.2017.11.006
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。