文献速递复苏、休克与脓毒症儿科与产科急症

婴儿胸外按压质量:急诊科基于视频的双拇指法与单手法的比较

Infant chest compression quality: A video-based comparison of two-thumb versus one-hand technique in the emergency department.
PubMed 文献 · Resuscitation · 2017-11-20
一句话结论婴儿胸外按压中单手位较双拇指环绕位按压频率更快且更常超出适当范围,但两者按压深度无显著差异。

本研究利用视频回顾比较婴儿心肺复苏中双拇指环绕(2T)与单手前位(1H)的胸外按压质量。共纳入7名婴儿、28名按压者、111分钟按压、80个按压段。2T用于41%的按压段。2T与1H的按压深度无显著差异(3.0±0.8 vs 3.0±0.6 cm,p=0.81),但1H的按压频率显著快于2T(134±18 vs 118±15次/分,p<0.001)。作者认为1H与更频繁的不适当过快按压频率相关,未来需研究手位对临床结局的影响。

要点

  • 在婴儿胸外按压中,1H手位的按压频率显著快于2T(134±18 vs 118±15次/分,p<0.001)。
  • 2T与1H的按压深度无显著差异(3.0±0.8 vs 3.0±0.6 cm,p=0.81)。
  • 所有按压段的中位按压频率为127次/分(IQR 115-142次/分),中位深度为3.0 cm(IQR 2.4-3.4 cm)。
  • 1H手位与更频繁的不适当过快按压频率相关,2T用于41%(33/80)的按压段。
  • 作者建议未来研究应评估手位对临床结局的影响。

适用人群与场景

  • 接受心肺复苏且胸外按压持续>2分钟并使用心肺复苏监测设备且被视频记录的婴儿。

研究设计与关键结果

  • 研究类型为基于视频回顾的观察性研究;共7名婴儿接受111分钟胸外按压,来自28名按压者;80个按压段被分析,按压段中位时长74秒(IQR 50-95秒)。
  • 所有按压段的中位按压频率为127次/分(IQR 115-142次/分),中位按压深度为3.0 cm(IQR 2.4-3.4 cm)。
  • 2T手位用于33/80(41%)的按压段。
  • 2T与1H的按压深度无显著差异(3.0±0.8 vs 3.0±0.6 cm,p=0.81)。
  • 1H手位的按压频率显著快于2T(134±18 vs 118±15次/分,p<0.001)。
  • 28名按压者中12名同时使用了2T和1H进行评估;6名按压者在同一患者中使用了2T和1H。

证据类型、等级与局限

  • 证据类型:基于视频回顾的观察性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,婴儿胸外按压中1H手位与更频繁的不适当过快按压频率相关,2T与1H在按压深度上无显著差异。
  • 作者建议未来研究应评估手位对临床结局的影响。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: To use video review to compare CC quality between 2-thumb encircling (2T) and one-hand anterior (1H) hand position in infants receiving CPR.

METHODS: Events where an infant received >2min of CC using a CPR monitor device while videorecorded were included. CC were measured in segments provided by a single compressor; segment duration, identity of the compressor, and hand position (2T vs 1H) was determined from video review. CC rate and depth were measured by the monitor device.

RESULTS: Seven infants received 111min of CCs from a total of 28 providers. 12/28 providers were assessed using both 2T and 1H; 6 providers used 2T and 1H in the same patient. 80 CC segments were analyzed; the median duration of CC segments was 74s (IQR 50-95s). Median CC rate across all segments was 127/min (IQR 115-142/min); median CC depth was 3.0cm (IQR 2.4-3.4cm). 2T position was used in 33/80 (41%) of segments. There was no significant difference in CC depth between 2T and 1H position (3.0±0.8 vs 3.0±0.6cm, p=0.81). 1H position was significantly associated with faster CC rate than 2T position (134±18 vs. 118±15 CC/min, p<0.001).

CONCLUSIONS: During CC in infants, 1H position was associated with a greater prevalence of inappropriately fast CC rate compared to 2T. There was no significant difference in depth between 2T and 1H. Future studies should evaluate the effect of hand position on clinical outcomes.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Jang HY, Wolfe H, Hsieh TC, et al. Infant chest compression quality: A video-based comparison of two-thumb versus one-hand technique in the emergency department. Resuscitation. 2017. PMID: 29158035. doi:10.1016/j.resuscitation.2017.11.044

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。