文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

肋下与右腋中线超声测量下腔静脉塌陷率的关系:对临床应用的启示

Relationship Between the Subcostal and Right Lateral Ultrasound Views of Inferior Vena Cava Collapse: Implications for Clinical Use of Ultrasonography.
PubMed 文献 · Chest · 2017-10-12
一句话结论右腋中线冠状面下腔静脉塌陷率(cIVCRC)会低估肋下矢状面测值(cIVCSS),两者不一致程度与下腔静脉扁平比(F-IVC)成正比;作者推荐 cIVCRC≥42% 仅用于确认(rule in)容量反应性,不能用于排除(rule out)。

这项单中心横断面研究纳入 110 例自主呼吸患者,比较右腋中线冠状面下腔静脉塌陷率(cIVCRC)与肋下矢状面塌陷率(cIVCSS)。以 cIVCSS≥42% 定义容量反应性时,cIVCRC≥42% 预测的敏感度为 61.5%(95%CI 31.58%-86.14%),特异度为 67.1%(95%CI 55.81%-77.06%)。cIVCRC 整体低估 cIVCSS,两者不一致程度与下腔静脉扁平比(F-IVC)成正比。作者据此推荐 cIVCRC≥42% 仅用于确认容量反应性,不能用于排除,并建议尽可能测量 F-IVC 以理解 cIVCRC 的临床相关性。

要点

  • 以 cIVCSS≥42% 为容量反应性参照,cIVCRC≥42% 的敏感度为 61.5%(95%CI 31.58%-86.14%),特异度为 67.1%(95%CI 55.81%-77.06%)。
  • cIVCRC 会低估 cIVCSS,两者不一致程度与下腔静脉扁平比(F-IVC)成正比。
  • 作者推荐 cIVCRC≥42% 仅用于确认(rule in)容量反应性,不能用于排除(rule out)。
  • 作者建议尽可能测量 F-IVC,以理解 cIVCRC 测值的临床相关性。
  • 研究为单中心横断面设计,纳入 110 例自主呼吸患者。

适用人群与场景

  • 110 例自主呼吸患者,单中心横断面研究人群。

诊断标准与关键阈值

  • 容量反应性参照标准:cIVCSS≥42%。
  • 下腔静脉扁平比(F-IVC)用于量化下腔静脉塌陷的不对称性。

研究设计与关键结果

  • 研究类型:单中心横断面研究,样本量 110 例自主呼吸患者。
  • 主要结果:以 cIVCSS≥42% 为参照,cIVCRC≥42% 预测容量反应性的敏感度为 61.5%(95%CI 31.58%-86.14%),特异度为 67.1%(95%CI 55.81%-77.06%)。
  • cIVCRC 低估 cIVCSS,两者不一致程度与 F-IVC 值成正比。

证据类型、等级与局限

  • 证据类型:单中心横断面研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者推荐 cIVCRC≥42% 仅用于确认(rule in)容量反应性,不能用于排除(rule out)。
  • 作者建议尽可能测量 F-IVC,以理解 cIVCRC 测值的临床相关性。
  • 使用右腋中线冠状面测量下腔静脉塌陷率时,需注意其可能低估肋下矢状面测值,两者不一致程度与 F-IVC 成正比。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The collapsibility index of the inferior vena cava is traditionally visualized from the subcostal region in the sagittal plane, referred to here as cIVCSS. Alternatively, the collapsibility index of the inferior vena cava can be visualized from the right midaxillary line in the coronal plane, referred to here as cIVCRC. It is unclear whether values of cIVCRC are comparable with values of cIVCSS because the inferior vena cava collapses asymmetrically into an elliptical form, quantified as the flat ratio of the inferior vena cava (F-IVC). This study aimed (1) to establish if cIVCRC is concordant or discordant to cIVCSS, and (2) to describe how this concordance or discordance is related to F-IVC.

METHODS: This single-center cross-sectional study enrolled 110 spontaneously breathing patients. Values of cIVCRC were compared with cIVCSS. Performance of cIVCRC ≥ 42% in predicting fluid responsiveness, defined as cIVCSS ≥ 42%, was assessed. F-IVC was also correlated to the difference between cIVCSS and cIVCRC.

RESULTS: cIVCRC ≥ 42% was 61.5% sensitive (95% CI, 31.58%-86.14%) and 67.1% specific (95% CI, 55.81%-77.06%) for predicting cIVCSS ≥ 42%. cIVCRC underestimated cIVCSS. The degree of discordance between cIVCRC and cIVCSS was proportional to the value of F-IVC.

CONCLUSIONS: cIVCRC and cIVCSS measures are discordant, where cIVCRC underestimates cIVCSS. The degree of discordance is directly proportional to the value of F-IVC. Therefore, we recommend that cIVCRC ≥ 42% be used to rule in, but not to rule out, fluid responsivity. Wherever possible, F-IVC should be assessed to understand the clinical relevance of cIVCRC.

来源:Chest,查看原文。版权归原作者所有。

参考来源

  1. Shah R, Spiegel R, Lu C, et al. Relationship Between the Subcostal and Right Lateral Ultrasound Views of Inferior Vena Cava Collapse: Implications for Clinical Use of Ultrasonography. Chest. 2017. PMID: 29032036. doi:10.1016/j.chest.2017.10.002

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。