文献速递复苏、休克与脓毒症

救护车转运中维持心肺复苏者平衡的稳定装置对院外心脏骤停心肺复苏质量的影响:一项前瞻性随机对照试验

[Effect of a stabilization device for maintaining the balance of a CPR performer during ambulance transportation on quality of CPR in out-of-hospital cardiac arrest: a prospective randomized controlled trial].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2017-01-01
一句话结论对心脏骤停时间<10分钟的院外心脏骤停患者,救护车转运中使用复苏者稳定装置可提高自主循环恢复率、24小时生存率和出院生存率。

该研究为前瞻性随机对照试验,纳入2014年10月至2017年1月沧州市中心医院收治的心脏骤停时间<10分钟的院外心脏骤停患者167例,按随机数字表分为使用稳定装置组(n=86)和未使用稳定装置组(n=81)。主要观察自主循环恢复率、24小时生存率和出院生存率。结果显示,使用稳定装置组自主循环恢复率29.1% vs 未使用组9.9%(χ2=9.691,P=0.002)、24小时生存率20.9% vs 6.2%(χ2=7.649,P=0.006)、出院生存率12.8% vs 3.7%(χ2=4.485,P=0.035)均显著升高。结论认为救护车转运中使用稳定装置进行心肺复苏可有效保证心肺复苏质量并改善院外心脏骤停患者预后。

要点

  • 院外心脏骤停且心脏骤停时间<10分钟的患者,救护车转运中使用复苏者稳定装置组自主循环恢复率29.1%,未使用组9.9%(χ2=9.691,P=0.002)。
  • 使用稳定装置组24小时生存率20.9%,未使用组6.2%(χ2=7.649,P=0.006)。
  • 使用稳定装置组出院生存率12.8%,未使用组3.7%(χ2=4.485,P=0.035)。
  • 该研究为前瞻性随机对照试验,共纳入167例院外心脏骤停患者,使用稳定装置组86例,未使用稳定装置组81例。

适用人群与场景

  • 沧州市中心医院2014年10月至2017年1月收治的院外心脏骤停患者,心脏骤停时间<10分钟,共167例。

研究设计与关键结果

  • 研究类型为前瞻性随机对照试验,纳入院外心脏骤停患者167例,按随机数字表分为使用稳定装置组(n=86)和未使用稳定装置组(n=81)。
  • 使用稳定装置组自主循环恢复率29.1% vs 未使用稳定装置组9.9%,使用稳定装置组升高(χ2=9.691,P=0.002)。
  • 使用稳定装置组24小时生存率20.9% vs 未使用稳定装置组6.2%,使用稳定装置组升高(χ2=7.649,P=0.006)。
  • 使用稳定装置组出院生存率12.8% vs 未使用稳定装置组3.7%,使用稳定装置组升高(χ2=4.485,P=0.035)。

证据类型、等级与局限

  • 证据类型:前瞻性随机对照试验。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,救护车转运中对院外心脏骤停患者使用稳定装置进行心肺复苏可有效保证心肺复苏质量并改善预后。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the effect of a stabilization device for maintaining the balance of a cardiopulmonary resuscitation (CPR) performer during ambulance transportation on quality of CPR in out-of-hospital cardiac arrest (OHCA).

METHODS: A prospective randomized controlled trial was performed. 167 OHCA patients with cardiac arrest (CA) time < 10 minutes admitted to Cangzhou Central Hospital from October 2014 to January 2017 were enrolled, and divided into armed stabilization device group (n = 86) and unarmed stabilization device group (n = 81) by random number table. Restoration of spontaneous circulation (ROSC) rate, 24-hour survival rate and survival rate of discharge were evaluated.

RESULTS: Compared with unarmed stabilization device group, ROSC rate (29.1% vs. 9.9%, χ2 = 9.691, P = 0.002), 24-hour survival rate (20.9% vs. 6.2%, χ2 = 7.649, P = 0.006) and survival rate of discharge (12.8% vs. 3.7%, χ2 = 4.485, P = 0.035) were significant increased in armed stabilization device group.

CONCLUSIONS: CPR with stabilization device during ambulance transport could effectively ensure quality of CPR and improve prognosis in OHCA.

CLINICAL TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR-IPR-14005337.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Guo J, Feng S, Wang B, et al. [Effect of a stabilization device for maintaining the balance of a CPR performer during ambulance transportation on quality of CPR in out-of-hospital cardiac arrest: a prospective randomized controlled trial]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2017. PMID: 29017658. doi:10.3760/cma.j.issn.2095-4352.2017.10.016

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。