肺重症医师床旁超声评估急性肺栓塞右心室功能的诊断准确性
前瞻性观察研究加回顾性病历复习,在450张床的城市教学医院纳入287例连续急性肺栓塞成人患者。肺重症 fellow 完成154次目标导向超声,其中110次在48小时内有完整心脏科审核的经胸超声心动图作对照。Fellow 评估右心室大小与功能的曲线下面积均为0.83(95%CI 0.75-0.90);重症主治医师盲法回顾的曲线下面积分别为0.87(95%CI 0.82-0.94)与0.87(95%CI 0.80-0.93),以及0.88(95%CI 0.82-0.95)与0.88(95%CI 0.82-0.95)。目标导向超声与经胸超声心动图的中位时间差为21小时18分钟。
要点
- 肺重症 fellow 目标导向超声评估右心室大小与功能的曲线下面积均为0.83(95%CI 0.75-0.90),与心脏科审核的经胸超声心动图对照。
- 重症主治医师盲法回顾的曲线下面积:右心室大小为0.87(95%CI 0.82-0.94)与0.87(95%CI 0.80-0.93),功能为0.88(95%CI 0.82-0.95)与0.88(95%CI 0.82-0.95)。
- 目标导向超声与经胸超声心动图的中位时间差为21小时18分钟,提示目标导向超声更及时。
- 作者认为,肺重症医师可以且应该对急性肺栓塞患者用目标导向超声筛查右心室功能障碍。
适用人群与场景
- 诊断为急性肺栓塞的成人住院与门诊患者。
处置流程与药物剂量
- 肺重症 fellow 执行并记录目标导向超声,将右心室大小与功能判为正常或异常。
- 目标导向超声显示关键发现时,按计划行金标准经胸超声心动图。
- 重症主治医师在不知临床情境下事后盲法回顾目标导向超声。
研究设计与关键结果
- 前瞻性观察研究加回顾性病历复习,在450张床的城市教学医院纳入287例连续急性肺栓塞患者。
- 肺重症 fellow 完成154次目标导向超声,其中110次在48小时内与完整心脏科审核的经胸超声心动图对照。
- Fellow 评估右心室大小与功能的曲线下面积均为0.83(95%CI 0.75-0.90)。
- 重症主治医师盲法回顾的曲线下面积:右心室大小0.87(95%CI 0.82-0.94)与0.87(95%CI 0.80-0.93),功能0.88(95%CI 0.82-0.95)与0.88(95%CI 0.82-0.95)。
- 目标导向超声与经胸超声心动图的中位时间差为21小时18分钟。
证据类型、等级与局限
- 证据类型:前瞻性观察研究加回顾性病历复习。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,肺重症医师可以且应该对急性肺栓塞患者用目标导向超声筛查右心室功能障碍。
- 目标导向超声的中位时间比经胸超声心动图早21小时18分钟,可能有助于及时风险分层。
- 适用人群为诊断为急性肺栓塞的成人住院与门诊患者。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: Risk stratification for acute pulmonary embolism using imaging presence of right ventricular dysfunction is essential for triage; however, comprehensive transthoracic echocardiography has limited availability. We assessed the accuracy and timeliness of Pulmonary Critical Care Medicine Fellow's performance of goal-directed echocardiograms and intensivists' interpretations for evaluating right ventricular dysfunction in acute pulmonary embolism.
DESIGN: Prospective observational study and retrospective chart review.
SETTING: Four hundred fifty bed urban teaching hospital.
PATIENTS: Adult in/outpatients diagnosed with acute pulmonary embolism.
INTERVENTIONS: Pulmonary critical care fellows performed and documented their goal-directed echocardiogram as normal or abnormal for right ventricular size and function in patients with acute pulmonary embolism. Gold standard transthoracic echocardiography was performed on schedule unless the goal-directed echocardiogram showed critical findings. Attending intensivists blinded to the clinical scenario reviewed these exams at a later date.
MEASUREMENTS AND MAIN RESULTS: Two hundred eighty-seven consecutive patients were evaluated for acute PE. Pulmonary Critical Care Medicine Fellows performed 154 goal-directed echocardiograms, 110 with complete cardiology-reviewed transthoracic echocardiography within 48 hours for comparison. Pulmonary Critical Care Medicine Fellow's area under the curve for size and function was 0.83 (95% CI, 0.75-0.90) and 0.83 (95% CI, 0.75-0.90), respectively. Intensivists' 1/2 area under the curve for size and function was (1) 0.87 (95% CI, 0.82-0.94), (1) 0.87 (95% CI, 0.80-0.93) and (2) 0.88 (95% CI, 0.82-0.95), (2) 0.88 (95% CI, 0.82-0.95). Median time difference between goal-directed echocardiogram and transthoracic echocardiography was 21 hours 18 minutes.
CONCLUSIONS: This is the first study to evaluate pulmonary critical care fellows' and intensivists' use of goal-directed echocardiography in diagnosing right ventricular dysfunction in acute pulmonary embolism. Pulmonary Critical Care Medicine Fellows and intensivists made a timely and accurate assessment. Screening for right ventricular dysfunction using goal-directed echocardiography can and should be performed by pulmonary critical care physicians in patients with acute pulmonary embolism.
参考来源
- Filopei J, Acquah SO, Bondarsky EE, et al. Diagnostic Accuracy of Point-of-Care Ultrasound Performed by Pulmonary Critical Care Physicians for Right Ventricle Assessment in Patients With Acute Pulmonary Embolism. Crit Care Med. 2017. PMID: 28953498. doi:10.1097/CCM.0000000000002723
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。