文献速递复苏、休克与脓毒症心脑血管急症

瑞典院外心脏骤停后自动胸外按压设备的使用情况

Use of automated chest compression devices after out-of-hospital cardiac arrest in Sweden.
PubMed 文献 · Resuscitation · 2017-09-06
一句话结论瑞典全国注册数据显示,2011至2015年院外心脏骤停患者中32.4%使用自动胸外按压设备,调整后30天生存率低于手动按压(OR 0.72)。

该研究基于瑞典心肺复苏注册登记(全国前瞻性Utstein参数登记),纳入2011至2015年所有院外心脏骤停并尝试复苏的患者共24,316例,评估自动胸外按压心肺复苏(ACC-CPR)的实施情况,次要目的为分析ACC-CPR与30天生存的关联。结果显示32.4%患者接受ACC-CPR,地区差异大(0.8%至78.8%);男性及初始可除颤心律与ACC-CPR使用相关,目击者见证状态与手动CPR相关;ACC-CPR组药物给予和气管插管等 prolonged resuscitation 标志更常见。未调整30天生存率为6.3%,倾向性评分匹配调整后ACC-CPR与30天生存的OR为0.72(95%CI 0.62-0.84,p<0.001,n=13922)。作者认为测量和未测量的混杂可能解释生存率较低的结果,但需要具体指南明确ACC-CPR的使用时机和方式。

要点

  • 瑞典2011至2015年24,316例院外心脏骤停患者中,32.4%接受了自动胸外按压心肺复苏(ACC-CPR),地区使用率从0.8%到78.8%不等。
  • 倾向性评分匹配调整后,使用ACC设备与30天生存的OR为0.72(95%CI 0.62-0.84,p<0.001,n=13922),ACC-CPR组生存率低于手动CPR组。
  • ACC-CPR组中药物给予和气管插管等 prolonged resuscitation 标志更常见,提示该组复苏尝试可能更长。
  • 男性性别和初始可除颤心律与ACC-CPR使用相关,而目击者见证状态与手动CPR相关。
  • 作者认为测量和未测量的混杂可能解释生存率较低的结果,并指出需要具体指南明确ACC-CPR的使用时机和方式,因为某些情况下这些设备可能弊大于利。

适用人群与场景

  • 瑞典2011至2015年所有院外心脏骤停并尝试复苏的患者,共24,316例,数据来自瑞典心肺复苏注册登记(全国前瞻性Utstein参数登记)。

研究设计与关键结果

  • 研究类型为基于全国前瞻性注册登记的队列研究,纳入24,316例院外心脏骤停尝试复苏患者,评估2011至2015年ACC-CPR实施情况,次要分析采用倾向性评分匹配调整已知混杂因素。
  • 32.4%患者接受ACC-CPR,地区使用率从0.8%至78.8%不等;男性性别和初始可除颤心律与ACC-CPR使用相关,目击者见证状态与手动CPR相关。
  • ACC-CPR组中药物给予和气管插管等 prolonged resuscitation 标志更常见。
  • 未调整30天生存率为ACC-CPR组6.3%;调整后ACC-CPR与30天生存的OR为0.72(95%CI 0.62-0.84,p<0.001,n=13922)。

证据类型、等级与局限

  • 证据类型为基于全国前瞻性注册登记的队列研究,采用倾向性评分匹配进行二次分析。
  • 局限:作者指出测量和未测量的混杂可能解释ACC-CPR组生存率较低的发现;原文未报告其他局限性。

对床旁实践的改变

  • 作者认为需要具体指南推荐ACC-CPR应在何时以及如何使用,因为某些情况下这些设备可能弊大于利。
  • 原文未据此给出其他推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the implementation of automated chest compression cardiopulmonary resuscitation (ACC-CPR) after out-of-hospital cardiac arrest (OHCA) in Sweden during the years 2011 through 2015. The association between ACC-CPR and 30-day survival was studied as a secondary objective.

METHODS: The Swedish cardiopulmonary resuscitation registry is a prospectively recorded nationwide registry of modified Utstein parameters including all patients with attempted resuscitation after OHCA. Propensity score matching (PSM) was used to adjust for known confounders in the secondary analysis.

RESULTS: Of the 24,316 patients included in the study population, 32.4% received ACC-CPR, with substantial regional variation ranging from 0.8% to 78.8%. Male gender and an initial shockable rhythm were associated with ACC-CPR, whereas crew witnessed status was associated with manual CPR. Potential markers of prolonged resuscitation attempts (drug administration and endotracheal intubation) were more prevalent in the ACC-CPR group. The unadjusted 30-day survival rate was 6.3% for ACC-CPR patients. The adjusted odds ratio for 30-day survival regarding use of an ACC device was 0.72 (95% CI 0.62-0.84, p<0.001, n=13922).

CONCLUSION: The use of ACC devices varied significantly between Swedish regions and overall survival to 30days was low among patients receiving ACC-CPR. Although measured and unmeasured confounding might explain our finding of lower survival rates for patients exposed to ACC-CPR, specific guidelines recommending when and how ACC-CPR should be used are warranted as there might be circumstances where these devices do more harm than good.

来源:Resuscitation,查看原文。版权归原作者所有。