文献速递复苏、休克与脓毒症

基于Kinect的实时视听反馈装置改善低体重施救者的心肺复苏质量

Kinect-based real-time audiovisual feedback device improves CPR quality of lower-body-weight rescuers.
PubMed 文献 · Am J Emerg Med · 2017-09-15
一句话结论模拟人训练中,基于Kinect的实时视听反馈装置可显著改善体重低于71kg施救者的胸外按压质量。

本研究为随机试验,纳入100名医护人员,在模拟人上分别以跪姿或站姿进行2分钟连续胸外按压,比较有无基于Kinect模块的实时视听反馈(AVF)装置对按压质量的影响。结果显示,跪姿按压频率高于站姿(111.4±22.6次/分 vs 99.1±18.9次/分,P=0.005);实时AVF反馈可改善按压深度、频率和有效按压比(6.16±1.88cm vs 5.54±1.89cm,P=0.02;103.2±21.0次/分 vs 96.7±25.8次/分,P=0.03;62.6±28.0% vs 51.0±33.2%,P=0.004)。无论有无实时反馈,按压深度与施救者体重相关;体重低于71kg的施救者从该装置中获益,按压质量改善。

要点

  • 模拟人训练中,使用基于Kinect的实时视听反馈装置可改善胸外按压深度(6.16±1.88cm vs 5.54±1.89cm,P=0.02)、频率(103.2±21.0次/分 vs 96.7±25.8次/分,P=0.03)和有效按压比(62.6±28.0% vs 51.0±33.2%,P=0.004)。
  • 跪姿按压频率高于站姿(111.4±22.6次/分 vs 99.1±18.9次/分,P=0.005)。
  • 无论有无实时反馈,胸外按压深度与施救者体重相关。
  • 体重低于71kg的施救者使用该装置后胸外按压质量改善。

适用人群与场景

  • 100名医护人员作为参与者,在模拟人上进行胸外按压训练。

研究设计与关键结果

  • 随机试验,纳入100名医护人员,在模拟人上分别以跪姿或站姿进行2分钟连续胸外按压,比较有无基于Kinect模块的实时视听反馈(AVF)装置。
  • 跪姿按压频率高于站姿(111.4±22.6次/分 vs 99.1±18.9次/分,P=0.005)。
  • 实时AVF反馈组按压深度优于无反馈组(6.16±1.88cm vs 5.54±1.89cm,P=0.02)。
  • 实时AVF反馈组按压频率优于无反馈组(103.2±21.0次/分 vs 96.7±25.8次/分,P=0.03)。
  • 实时AVF反馈组有效按压比优于无反馈组(62.6±28.0% vs 51.0±33.2%,P=0.004)。
  • 无论有无实时反馈,按压深度与施救者体重相关;体重低于71kg的施救者使用该装置后按压质量改善。

证据类型、等级与局限

  • 证据类型:随机试验。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在模拟人训练中,对体重低于71kg的医护人员使用基于Kinect的实时视听反馈装置,可改善胸外按压深度、频率和有效按压比。
  • 模拟人训练中采用跪姿按压可获得比站姿更高的按压频率。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Chest compression (CC) quality is associated with rescuer posture and body weight. We designed a Kinect module-based real-time audiovisual feedback (AVF) device to investigate the relationship between rescuer posture, body weight, and CC quality.

METHODS: A total of 100 healthcare professionals were enrolled as participants in this randomized trial. A Kinect-based sensor system was used to monitor the depth and rate of CC and provide further real-time feedback. All participants were asked to perform continuous CC on a manikin with and without feedback for 2min individually in either a kneeling or standing position.

RESULTS: A kneeling posture can provide higher rate of CC than a standing posture can (111.4±22.6 per minute vs. 99.1±18.9per minute, p value=0.005). Real-time AVF feedback can provide a better compression depth, rate, and effective compression ratio (6.16±1.88cm vs. 5.54±1.89cm, p value=0.02; 103.2±21.0/min vs. 96.7±25.8/min, p value=0.03; 62.6±28.0% vs. 51.0±33.2%, p value=0.004). Regardless of the effect of real-time feedback, the CC depth correlated to the rescuers' body weight. Rescuers who weighed below 71kg benefited from the Kinect module-based real-time AVF device in terms of improved CC quality.

CONCLUSION: The Kinect-based AVF device can significantly improve CC quality in manikin training in rescuers with their body weight<71kg.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Wang JC, Tsai SH, Chen YH, et al. Kinect-based real-time audiovisual feedback device improves CPR quality of lower-body-weight rescuers. Am J Emerg Med. 2017. PMID: 28927950. doi:10.1016/j.ajem.2017.09.022

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。