文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

JCI背景下呼吸机集束化措施可有效降低呼吸机相关性肺炎发生率

[Ventilator bundle guided by context of JCI settings can effectively reduce the morbidity of ventilator-associated pneumonia].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2017-01-01
一句话结论在JCI背景下逐年提高呼吸机集束化措施依从性,可将VAP发生率从2013年17.0例/千机械通气日降至2016年3.5例/千机械通气日(IRR 0.21)。

该前瞻性研究纳入厦门大学附属第一医院重症医学科2013年1月至2016年12月需机械通气的患者,在JCI背景下逐年加强呼吸机集束化措施依从性(2013年建立预防措施并加强教育,2014年强化手卫生和床头抬高,2015年引入氯己定冲洗的吸痰管海绵刷行口腔护理,2016年采用电子集束化核查表每日自查)。最终分析1399例机械通气患者,总机械通气日11012天,94例发生VAP。VAP年发生率从2013年17.0例/千机械通气日逐年降至2016年3.5例/千机械通气日,以2013年为基准,2014至2016年IRR分别为0.59、0.35、0.21,均有统计学意义。吸痰管海绵刷联合氯己定口腔护理组(30例)口臭、污垢残留和牙菌斑发生率显著低于传统棉球联合氯己定组(30例)。

要点

  • 在JCI背景下逐年提高呼吸机集束化措施依从性,VAP发生率从2013年17.0例/千机械通气日降至2016年3.5例/千机械通气日,IRR 0.21(95%CI 0.09-0.41,P<0.05)。
  • 2016年较2013年集束化依从性显著提高:每日唤醒与脱机95.00% vs. 71.43%,床头抬高>30度92.50% vs. 28.57%,手卫生97.50% vs. 54.29%,氯己定口腔护理每6-8小时一次95.00% vs. 62.86%,翻身与体位引流97.50% vs. 80.00%(均P<0.05)。
  • 吸痰管海绵刷冲洗氯己定行口腔护理组(30例)口臭10.0% vs. 传统棉球组40.0%、污垢残留16.7% vs. 70.0%、牙菌斑3.3% vs. 30.0%(均P<0.05),口腔溃疡发生率两组无显著差异(10.0% vs. 30.0%,P>0.05)。
  • 2013年ICU患者床头抬高和手卫生依从率最低,分别为28.57%和54.29%;经两个品管圈项目实施后,2014年分别提高至82.35%和91.18%(均P<0.05)。
  • 2014年执行最差的氯己定口腔护理经品管圈方法改进后,2015年依从率87.10%显著高于2013年62.86%(P<0.05)。

适用人群与场景

  • 厦门大学附属第一医院重症医学科2013年1月至2016年12月需机械通气的ICU患者。
  • 排除社区获得性肺炎、吸入性肺炎、床头抬高禁忌、资料不完整及退出研究的患者。

处置流程与药物剂量

  • 2013年建立预防措施并加强教育。
  • 2014年通过两个品管圈项目强化手卫生和床头抬高依从性。
  • 2015年通过品管圈方法改进氯己定口腔护理依从性,引入氯己定冲洗的吸痰管海绵刷行口腔护理。
  • 2016年采用电子集束化核查表进行每日自查。
  • 集束化措施包括:每日唤醒与脱机、床头抬高>30度、手卫生、氯己定口腔护理每6-8小时一次、翻身与体位引流。

研究设计与关键结果

  • 前瞻性研究,纳入1399例机械通气患者(总机械通气日11012天),94例发生VAP。
  • VAP年发生率从2013年17.0例/千机械通气日逐年降至2014年10.0、2015年5.9、2016年3.5例/千机械通气日。
  • 以2013年为基准,2014至2016年VAP的IRR分别为0.59(95%CI 0.35-0.98)、0.35(95%CI 0.18-0.64)、0.21(95%CI 0.09-0.41),均有统计学意义(均P<0.05)。
  • 口腔护理对照研究:吸痰管海绵刷联合氯己定组30例 vs. 传统棉球联合氯己定组30例,口臭10.0% vs. 40.0%、污垢残留16.7% vs. 70.0%、牙菌斑3.3% vs. 30.0%(均P<0.05);口腔溃疡10.0% vs. 30.0%(P>0.05)。

证据类型、等级与局限

  • 证据类型:前瞻性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在JCI背景下,逐年强化呼吸机集束化措施依从性(教育、品管圈改进手卫生与床头抬高、氯己定口腔护理、电子核查表每日自查)与VAP发生率逐年下降相关。
  • 作者认为,吸痰管海绵刷联合氯己定行口腔护理可有效改善口腔卫生。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To observe the impact of improving the compliance of ventilator bundle on morbidity of ventilator-associated pneumonia (VAP) in intensive care unit (ICU) patients undergoing mechanical ventilation (MV) guided by context of Joint Commission International (JCI) settings, and to study the oral care efficacy of suction tube sponge brush.

METHODS: A prospective study was conducted. The patients who needed MV admitted to Department of Critical Care Medicine of the First Affiliated Hospital of Xiamen University from January 2013 to December 2016 were enrolled. In the context of JCI settings, necessary measurements were taken to enhance the compliance of ventilator bundle each year. In 2013, the preventive measures were set up and the education was strengthened. In 2014, the compliance of hand hygiene and bedside elevation was strengthened. In 2015, a control study was conducted to evaluate the effect between the traditional cotton dipped in chlorhexidine and the suction tube sponge brush rinsed with chlorhexidine on oral health impact parameters. The suction tube sponge brush rinsed with chlorhexidine oral care was introduced to improve compliance. In 2016, electronic bundle checklist for daily self-audits was conducted. The annually morbidity of VAP through the software of hospital and ICU was collected and calculated. The annual incidence of VAP was indicated by the VAP cases per 1 000 MV days. Based on the VAP incidence rate in 2013 as 1, the VAP incidence-rate ratio (IRR) of each year was calculated.

RESULTS: During the study period, a total of 2 733 patients admitted to the ICU, including 1 403 patients undergoing MV. Ninety-four of the 1 403 patients with community-acquired pneumonia (CAP), aspiration pneumonia, back elevation ban, incomplete information, and withdrew from the study were excluded. 1 399 patients undergoing MV were enrolled in the final analysis, with total MV days of 11 012 days, and 94 patients occurred VAP. The annual incidence of VAP was progressively declined from 2013 to 2016, and the VAP cases per 1 000 MV days were 17.0, 10.0, 5.9, 3.5 cases, respectively. Based on the VAP incidence rate in 2013, the IRR of VAP from 2014 to 2016 was also progressively declined, which was 0.59 [95% confidence interval (95%CI) = 0.35-0.98], 0.35 (95%CI = 0.18-0.64), and 0.21 (95%CI = 0.09-0.41), with statistical significance (all P < 0.05). In 2013, ICU patients had the lowest rates of bedside elevation and hand hygiene compliance, which were 28.57% and 54.29%, respectively. Compared with 2013, by the implementation of two quality control circle (QCC) projects for bedside elevation and hand hygiene, the rates of bedside elevation and hand hygiene compliance were improved significantly in 2014, which were 82.35%, 91.18%, respectively (both P < 0.05). In 2015, the compliance of chlorhexidine oral care which was the worst performed in 2014 had been improved by the method of QCC, and the rate of the compliance was significantly higher than that in 2013 (87.10% vs. 62.86%, P < 0.05). Compared with 2013, bundle compliance was significantly increased in 2016, except for the sterile operation of the suction tube [daily wake and weaning: 95.00% vs. 71.43%, bedside elevation for over 30degree angle: 92.50% vs. 28.57%, hand hygiene: 97.50% vs. 54.29%, chlorhexidine mouth care once per 6-8 hours: 95.00% vs. 62.86%, turned back and posture drainage: 97.50% vs. 80.00%], the differences were statistically significant (all P < 0.05). The incidences of bad breath, dirt residue and plaque were significantly lower in the group of oral care by using suction tube sponge brush with chlorhexidine (30 cases) compared with the group of traditional cotton pad with chlorhexidine (30 cases; bad breath: 10.0% vs. 40.0% %, dirt residue: 16.7% vs. 70.0%, plaque: 3.3% vs. 30.0%, all P < 0.05). There was no significant difference in the incidence of oral ulcers between the oral brush group and the traditional group (10.0% vs. 30.0%, P > 0.05).

CONCLUSIONS: Ventilator bundle can effectively reduce the morbidity of VAP in the context of JCI settings, and the oral care by using suction tube sponge brush and chlorhexidine can effectively improve oral hygiene.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Zhao L, Liu L, Chen J, et al. [Ventilator bundle guided by context of JCI settings can effectively reduce the morbidity of ventilator-associated pneumonia]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2017. PMID: 28743340. doi:10.3760/cma.j.issn.2095-4352.2017.07.010

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。